Standards, or specific sections thereof, cited in this Code, including Annex, Appendixes, or Supplements where prescribed, are referenced without exception in this Code, unless specifically noted. Cited standards are listed in the following with their serial designations, including year of adoption or revision.
LRFDUS-8—LRFD Bridge Design Specifications, 8th Edition, 2017, Articles 5.8.4.4.2, 5.8.4.4.3, and 5.8.4.5
LRFDCONS-4—LRFD Bridge Construction Specifications, Fourth Edition, 2017, Article 10.3.2.3
301-16—Specifications for Structural Concrete, Article 4.2.3
318.2-19—Building Code Requirements for Concrete Thin Shells and Commentary
332-14—Residential Code Requirements for Structural Concrete and Commentary
355.2-19—Qualification of Post-Installed Mechanical Anchors in Concrete and Commentary
355.4-11—Qualification of Post-Installed Adhesive Anchors in Concrete
369.1-17—Standard Requirements for Seismic Evaluation and Retrofit of Existing Concrete Buildings (369.1-17) and Commentary
374.1-05—Acceptance Criteria for Moment Frames Based on Structural Testing
423.7-14—Specification for Unbonded Single-Strand Tendon Materials
437.2-13—Code Requirements for Load Testing of Existing Concrete Structures and Commentary
550.3-13—Design Specification for Unbonded Post-Tensioned Precast Concrete Special Moment Frames Satisfying ACI 374.1 and Commentary
550.4-18—Qualification of Precast Concrete Diaphragm Connections and Reinforcement at Joints for Earthquake Loading and Commentary
550.5-18—Code Requirements for the Design of Precast Concrete Diaphragms for Earthquake Motions and Commentary
ITG-5.1-07—Acceptance Criteria for Special Unbonded Post-Tensioned Precast Structural Walls Based on Validation Testing
ITG-5.2-09—Requirements for Design of a Special Unbonded Post-Tensioned Precast Wall Satisfying ACI ITG-5.1 and Commentary
ASCE/SEI 7-16—Minimum Design Loads for Buildings and Other Structures, Sections 2.3.2, Load Combinations Including Flood Loads; and 2.3.3, Load Combinations Including Atmospheric Ice Loads
A184/A184M-17—Standard Specification for Welded Deformed Steel Bar Mats for Concrete Reinforcement
A307-14ε1—Standard Specification for Carbon Steel Bolts, Studs, and Threaded Rod 60000 PSI Tensile Strength
A370-18—Standard Test Methods and Definitions for Mechanical Testing of Steel Products
A416/A416M-18—Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
A421/A421M-15—Standard Specification for Uncoated Stress-Relieved Steel Wire for Prestressed Concrete, including Supplementary Requirement SI, Low-Relaxation Wire and Relaxation Testing
A615/A615M-18ε1—Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement
A706/A706M-16—Standard Specification for Deformed and Plain Low-Alloy Steel Bars for Concrete Reinforcement
A722/A722M-18—Standard Specification for Uncoated High-Strength Steel Bars for Prestressing Concrete
A767/A767M-16—Standard Specification for Zinc-Coated (Galvanized) Steel Bars for Concrete Reinforcement
A775/A775M-17—Standard Specification for Epoxy-Coated Steel Reinforcing Bars
A820/A820M-16—Standard Specification for Steel Fibers for Fiber-Reinforced Concrete
A884/A884M-14—Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement
A934/A934M-16—Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars
A955/A955M-18b—Standard Specification for Deformed and Plain Stainless-Steel Bars for Concrete Reinforcement
A970/A970M-18—Standard Specification for Headed Steel Bars for Concrete Reinforcement, including Annex A1 Requirements for Class HA Head Dimensions
A996/A996M-16—Standard Specification for Rail-Steel and Axle-Steel Deformed Bars for Concrete Reinforcement
A1022/A1022M-16b—Standard Specification for Deformed and Plain Stainless Steel Wire and Welded Wire for Concrete Reinforcement
A1035/A1035M-16b—Standard Specification for Deformed and Plain, Low-Carbon, Chromium, Steel Bars for Concrete Reinforcement
A1044/A1044M-16a—Standard Specification for Steel Stud Assemblies for Shear Reinforcement of Concrete
A1055/A1055M-16—Standard Specification for Zinc and Epoxy Dual-Coated Steel Reinforcing Bars
A1060/A1060M-16b—Standard Specification for Zinc-Coated (Galvanized) Steel Welded Wire Reinforcement, Plain and Deformed, for Concrete
A1064/A1064M-18a—Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete
C29/C29M-17a—Standard Test Method for Bulk Density ("Unit Weight") and Voids in Aggregate
C31/C31M-19—Standard Practice for Making and Curing Concrete Test Specimens in the Field
C33/C33M-18—Standard Specification for Concrete Aggregates
C39/C39M-18—Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
C42/C42M-18a—Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete
C94/C94M-18—Standard Specification for Ready-Mixed Concrete
C138-17a—Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
C150/C150M-19a—Standard Specification for Portland Cement
C172/C172M-17—Standard Practice for Sampling Freshly Mixed Concrete
C173/C173M-16—Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method
C192-18—Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory
C231/C231M-17a—Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
C260/C260M-10a(2016)—Standard Specification for Air-Entraining Admixtures for Concrete
C330/C330M-17a—Standard Specification for Lightweight Aggregates for Structural Concrete
C469/C469M-14—Standard Test Method for Static Modulus of Elasticity and Poisson's Ratio of Concrete in Compression
C494/C494M-17—Standard Specification for Chemical Admixtures for Concrete
C567/C567M-14—Standard Test Method for Determining Density of Structural Lightweight Concrete
C595/C595M-19—Standard Specification for Blended Hydraulic Cements
C618-19—Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C685/C685M-17a—Standard Specification for Concrete Made by Volumetric Batching and Continuous Mixing
C845/C845M-18—Standard Specification for Expansive Hydraulic Cement
C989/C989M-18a—Standard Specification for Slag Cement for Use in Concrete and Mortars
C1012/C1012M-18b—Standard Test Method for Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate Solution
C1017/C1017M-13ε1—Standard Specification for Chemical Admixtures for Use in Producing Flowing Concrete
C1077-17—Standard Practice for Agencies Testing Concrete and Concrete Aggregates for Use in Construction and Criteria for Testing Agency Evaluation
C1116/C1116M-10a(2015)—Standard Specification for Fiber-Reinforced Concrete
C1140-11—Standard Practice for Preparing and Testing Specimens from Shotcrete Test Panels
C1141-15—Standard Specification for Admixtures for Shotcrete
C1157/C1157M-17—Standard Performance Specification for Hydraulic Cement
C1218/C1218M-17—Standard Test Method for Water-Soluble Chloride in Mortar and Concrete
C1240-15—Standard Specification for Silica Fume Used in Cementitious Mixtures
C1436-13—Standard Specification for Materials for Shotcrete
C1480-07(2012)—Standard Specification for Packaged, Pre-Blended, Dry, Combined Materials for Use in Wet or Dry Shotcrete Application
C1580-15—Standard Test Method for Water-Soluble Sulfate in Soil
C1582/C1582M-11(2017)ε1—Standard Specification for Admixtures to Inhibit Chloride-Induced Corrosion of Reinforcing Steel in Concrete
C1602/C1602M-18—Standard Specification for Mixing Water Used in the Production of Hydraulic Cement Concrete
C1604-05(2012)—Standard Test Method for Obtaining and Testing Drilled Cores of Shotcrete
C1609/C1609M-12—Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam with Third-Point Loading)
C1797-17—Standard Specification for Ground Calcium Carbonate and Aggregate Mineral Fillers for use in Hydraulic Cement Concrete
D516-16—Standard Test Method for Sulfate Ion in Water
D4130-15—Standard Test Method for Sulfate Ion in Brackish Water, Seawater, and Brines
D1.1/D1.1M: 2015—Structural Welding Code — Steel
D1.4/D1.4M: 2018—Structural Welding Code — Steel Reinforcing Bars