The Southern Nevada Fire Chiefs Associated Approved Guideline for Consumer Fireworks is hereby adopted into the Clark County Fire Code.
TITLE:
To provide for the issuance of permits for the sale and storage of fireworks classified as U.N. explosive class 1.4G "consumer fireworks" (formerly class C fireworks).
REFERENCE:
International Fire Code (IFC), Clark County Amendments to the IFC, NFPA 1124, Code for the Manufacture, Transportation, Storage, Retail Sales of Fireworks and Pyrotechnic Articles.
PURPOSE:
To standardize Authority Having Jurisdiction requirements throughout Southern Nevada with all jurisdictions, regarding the issuance of permits for the sale, storage and use of U.N. explosive class 1.4G "consumer fireworks."
This handout is a guideline provided as a public service and is not intended to be a reprint of every code section which addresses this issue. The user of this document is required to comply with all code requirements, laws, ordinances, etc., Authority Having Jurisdiction or otherwise which apply to the sales, storage and use of fireworks. The Authority Having Jurisdiction may require more stringent conditions than noted in this document.
TITLE:
CONSUMER FIREWORKS
SCOPE: To provide for the issuance of permits for the sale and storage of fireworks classified as U.N. explosive class 1.4G "consumer fireworks" (formerly class C fireworks).
REFERENCE:
International Fire Code (IFC), Clark County Amendments to the IFC, NFPA 1124, Code for the Manufacture, Transportation, Storage, Retail Sales of Fireworks and Pyrotechnic Articles.
- The current Fire Code and / or amendments in effect for the specific jurisdiction.
- Testing procedures are labeled as Attachment #1 and are based on the requirements set forth in the APA (American Pyrotechnics Association) standard 87-1
- This attachment is for the SNCFCC Only
PURPOSE:
To standardize Authority Having Jurisdiction requirements throughout Southern Nevada with all jurisdictions, regarding the issuance of permits for the sale, storage and use of U.N. explosive class 1.4G "consumer fireworks."
General Requirements
This handout is a guideline provided as a public service and is not intended to be a reprint of every code section which addresses this issue. The user of this document is required to comply with all code requirements, laws, ordinances, etc., Authority Having Jurisdiction or otherwise which apply to the sales, storage and use of fireworks. The Authority Having Jurisdiction may require more stringent conditions than noted in this document.
- All product being used for retail sales, transporting, possess, store or manufactured must be through a Nevada State licensed, federally licensed and SNCFCC approved wholesaler.
- A permit shall be obtained for the storage and sale of fireworks. The wholesaler shall submit an application for a storage site, and each retail site (fireworks retail sales stand / booth). Said application shall be made on a form supplied by the Authority Having Jurisdiction.
- The Authority Having Jurisdiction shall review the permit packets and either approve or disapprove them within a reasonable time frame.
- The issuance of a permit for the sale and storage of fireworks shall not preclude the Authority Having Jurisdiction from subsequently revoking the permit, imposing additional requirements, or supplementing any existing requirement whenever, in the opinion of the above, later information or newly discovered conditions justify such actions.
- The Fire Prevention Division for each Authority Having Jurisdiction (or in combination) shall hold at least two (2) orientation meetings. These meetings shall be to review this Guideline and specific jurisdictional requirements and shall be before May 25th of each year. Each retailer shall attend at least one meeting for the specific jurisdiction where the retail sales stand / booth is to be located.
- Any representative can attend for all firework stands / booth locations for one organization. If there are more than 3 retail sales stand / booth per organization, 2 representatives shall attend the orientation and 1 person per every 3 retail sales stand / booth thereafter. Any representative can be available for the inspection of the fireworks retail sales stand / booth on the day and time listed on the orientation form.
- Except as hereinafter provided, it shall be unlawful for any person to possess, store, offer for sale, expose for sale, sell at retail, or use or explode any consumer fireworks, provided that the Authority Having Jurisdiction shall have power to adopt reasonable rules and regulations for the granting of permits for supervised public display of fireworks by persons, corporations, associations, or other organizations.
- The retail sale of fireworks shall only take place in fire department / fire code official authorized fireworks retail sales stand / booth by recognizable local charitable and not for profit organizations. A permit shall be obtained by the local AHJ.
- No person, firm or corporation shall offer fireworks for sale to the public before the 1st day of July or after the 4th day of July each year.
- The possession, storage, and use of approved consumer fireworks accepted by the SNCFCC and the Authority having Jurisdiction is permitted only from July 1st through July 4th.
- To obtain an approval by the Authority Having Jurisdiction, the applicant shall:
- Submit a completed application form.
- Provide a site plan of the proposed location indicating all buildings, property lines, roadways, distances etc. Any deviation from the approved structure and/or site plan requires a submittal of the revised plan and must be approved.
- • An approved address is required.
- Certificate of Insurance
- • The permittee / applicant shall furnish a certificate of insurance for at least $1,000,000 or greater as specified by Authority Having Jurisdiction.
- • The insurance policy shall be for the payment of damages, which could be caused either to a person or persons or to property arising from acts of the permittee, agents, employees or subcontractors.
- Provide proof of attendance at an orientation meeting.
- Provide a copy of the contract for fireworks sales between the SNCFCC approved Wholesaler and the Retailers.
- Provide a copy of the agreement / contract between the SNCFCC approved wholesalers and the land owner to allow a sales stand / booth on their property.
- • The address where the stand / booth will be located must be on the agreement / contract.
- Revocation of Permits
- The sale of fireworks is a privilege, which may be suspended or revoked
by the Authority Having Jurisdiction when it is determined that any of the
following occurred: - A permit is used by an organization other than the organization for which
the permit was issued. - A permit is used for a location other than that for which it was issued.
- Any of the conditions or limitations set forth in the permit have been
violated. - The permittee fails, refuses, or neglects to comply with any order or notice duly served upon him or the organization under the provisions of
jurisdictional requirements and / or this guideline within the time provided
therein. - Fireworks are discovered to be stored at a location other than indicated on the application for permit.
- The permittee sells any fireworks which were not obtained from a
SNCFCC approved wholesaler. - Any fireworks specifically not on the approved list that are found on the
premises (to include vehicles and trailers) are grounds for revocation of
permit. - Any violations discovered by local authorities that is against this
guideline, local laws or local jurisdiction requirements.
- The sale of fireworks is a privilege, which may be suspended or revoked
Wholesaler shall provide instruction / demonstration to the Retailers on the proper method of stand / booth setup prior to the fireworks retail sales stand / booth
- Fireworks Stand / Booth Inspections:
- Fireworks stands / booths shall be inspected and approved by the Authority Having Jurisdiction at any time starting July 1st.
- The Authority Having Jurisdiction has the right to re-inspect any previously inspected and / or approved fireworks retail sales stands / booths at any time between July 1st and July 4th.
- Size of Stands / Booths
- No fireworks retail sales stand / booth shall exceed 16 feet 6 inches in length or 8 feet in width.
Exception: Any fireworks retail sales stand / booth exceeding these dimensions must be approved by the Authority Having Jurisdiction prior to construction.
- No fireworks retail sales stand / booth shall exceed 16 feet 6 inches in length or 8 feet in width.
- Construction of Stand / Booths
- Siding and roof shall be made of 1/4-inch or thicker plywood (or comparable material) or of Non-combustible materials. Converted travel-type trailers may be permitted. The fireworks retail sales stand / booth construction must be structurally sound.
- Exiting for fireworks retail sales stand / booths shall comply with subsection "5" of this section.
- All fireworks retail sales stand / booth used for sales of fireworks must be
approved by the Authority Having Jurisdiction.
- Electrical Wiring and Appliances
- All electrical wiring and appliances shall meet the requirements of the National Electrical Code.
- Electrical wiring and lighting shall be "U.L." listed for outside use when exposed to the elements.
- Electrical wiring shall be properly sized for its use.
- All electrical wiring shall be protected from physical injury.
- Portable electric generator locations shall be at least 20 feet away from the stand / booth.
- Minimum height of electrical wiring when placed from a utility pole or a building to the fireworks retail sales stand / booth is 13 feet 6 inches above grade.
- Exits
- The fireworks retail sales stand / booth shall have no less than 2 exits (minimum of 6 feet in height and 2 feet in width).
- The counter shall not be considered an exit.
- Exit path shall be free and clear of all obstructions at all times.
- Aisles: In temporary consumer fireworks retail sales stand / booths where the interior is not accessible to the public, the minimum clear width of the aisle shall be permitted to be not less than 28 inches.
- Location / Distances / Attachments
- Tarps shall be allowed to be attached to the roof for protection from the elements.
- • Tarps shall be flame retardant and shall indicate this via certificate from the manufacture, on packaging (if indicated on packaging, the package shall remain with the tarp at all times) or on the tarp(s) itself.
- • Tarps shall be firmly secured in a manner that at no point shall any portion more than 1 foot of the tarp hangs over the edge of the roof edges of the stand / booth.
- o Tarp must not block the "No Smoking" symbol or signs o Type of tarps allowed to be used:
- o Tarps must be removed by organization at end of sale season
- o Method(s) for securing tarps allowed: Attach tarp using a screw and washer through each grommet
- • Provides secure attachment to booth A minimum 1inch screw shall be used to secure tarp.
- Fireworks retail sales stand / booths shall be so located as to not endanger persons, buildings, structures, property, brush, automotive vehicles and/or equipment, etc. Booths shall be located away from other hazards to include but not be limited to what is outlined in the following table:
- Tarps shall be allowed to be attached to the roof for protection from the elements.
Minimum separation distances from fireworks retail sales stand / booth
|
||||
5 feet
|
10 feet
|
20 feet
|
30 feet
|
0 feet
|
Metal or aluminum pop up canopies |
Vehicle Parking Curb or edge of roadway, street, or driveway, etc. Air / Water dispensers |
Buildings Tents Fireworks Storage Other fireworks retail sales stand / booth Temp Generators and extra fuel Underground storage tank fuel fill ports |
Combustibles (including empty product boxes, dry grass, dry brush and any combustible debris) |
Motor vehicle fuel dispensers Propane dispensers Compressed natural gas dispensing facilities Aboveground storage tanks for flammable or combustible liquids, flammable compressed gasses including propane. Any cooking equipment (BBQ's) Ignition Sources (Matches, lighters etc.) |
- Wholesalers shall obtain a permit from Authority Having Jurisdiction and/or other permits or licenses required for the possession and storage of fireworks prior to possession, storage, and/or transportation of fireworks.
- The wholesaler shall ensure that each charitable or not for profit organization submits one completed permit application and required documents for a permit for each proposed fireworks retail sales stand / booth location. These forms can be submitted to the Authority Having Jurisdiction at any time, once they have attended the required orientation and prior to June 1st of the current sales year.
- Permits shall at all times be kept on the storage premises and said premises shall at all times be subject to inspection by an officer of the fire or police department or other authorized persons.
- Wholesalers are to inform the Authority Having Jurisdiction, in writing, by the 1st of May as to where they are proposing to store their products.
- Wholesalers shall not permit fireworks from leaving storage yards until the first day of the authorized sales day (July 1st).
- Wholesalers shall be required to present a copy of the guidelines and ensure the retailer understands the contents of the guideline; at time of application.
- Wholesaler must inform the applicants of all requirements for sale of fireworks.
- The wholesaler shall furnish a certificate of insurance at the time of permit submittal in the amount deemed adequate by the Authority Having Jurisdiction for the payment of damages which could be caused either to a person or persons or to property arising from acts of the permittee, agents, employees or subcontractors.
- The permittee / wholesaler shall provide the name of the insurance company to furnish the policy at the time of the application. The amount of coverage shall be at least $1,000,000 or greater as specified by Authority Having Jurisdiction public liability & property damage. The insurance policy shall designate the Authority Having Jurisdiction as an additional insured there under.
- Testing and acceptance procedures are according to the SNCFCC Guideline for Consumer Fireworks Testing and Acceptance Procedure; attachment #1. This document is available upon request from the SNCFCC, Wholesaler or any local fire department's Fire Prevention Division.
- Handhelds shall be tested every year and other materials / products (fountains, spinners, smoke balls etc.) shall be tested every 5 years.
- All fireworks must be labeled with a permanently affixed Safe and Sane seal / label. (Stickers are not acceptable.)
- Product must be packaged and labeled the way it is to be sold.
- The testing of materials / products will be conducted / witnessed by Authority Having Jurisdiction SNCFCC members and shall be completed by April 30th of each sales year.
- Retailers shall be limited to local charitable, fraternal, and non-profit organizations and shall obtain a permit from the Authority Having Jurisdiction through the approved wholesaler, for possession, storage, transportation, sales, and/or use of fireworks prior to storage or sale of fireworks.
- A proof of orientation attendance certificate will be given to the fireworks retail sales stand / booth representative signed on the day of the orientation and will be required to be in a readily accessible location in the fireworks retail sales stand / booth prior to any permit being issued.
- A copy of this guideline shall be at a readily accessible location in the fireworks retail sales stand / booth, and every worker in the booth shall have signed the signature sheet indicating that they have read and understand the guideline.
- Retailers shall be permitted to sell approved consumer fireworks obtained from a SNCFCC approved Wholesaler.
- Permits shall at all times be kept in the fireworks retail sales stand / booth and said premises and shall at all times be subject to inspection by an officer of the fire or police department or other authorized persons.
- Fireworks shall not be ignited, discharged, or otherwise used within 300 feet of a consumer fireworks retail sales stand / booth or store, gasoline service station buildings, gasoline dispensers, flammable or combustible liquid tank fill or vent lines, above ground flammable or combustible liquid tanks or any building, structure or vehicle containing unsealed flammable or combustible liquids, hazardous materials, or explosives.
- Ignition of fireworks shall take place so as to not endanger persons, buildings, structures, property, brush, automotive vehicles and/or equipment, etc.
- Ignition of fireworks shall not take place before the 1st day of July or after the 4th day of July.
- No person under 16 years of age shall be allowed in a fireworks retail sales stand / booth
- Booths must at all times have at least one adult and two people in the fireworks retail sales stand / booth at all times during operation. One of which must be 18 years or older.
- Storing materials / products in fireworks retail sales stand / booths overnight require only one person to remain alert and awake at all times.
- Limit the amount of people in the fireworks retail sales stand / booth to a max of 4 at one time.
- Approx. 2 people per 8 feet panel / section of booth.
- Bigger, approved custom booths will be addressed the same way
- Fire Protection
- An approved minimum rated 2Al0-B:C fire extinguisher(s)* is required in each fireworks retail sales stand / booth. These are provided by the wholesaler when the Retailer picks up the product.
- The extinguisher must be installed prior to stocking of product.
- • Must be mounted to wall of booth. 4 inch off floor up to 5 ft high
- • Must have current tag by a Nevada State Licensee*
- "NO SMOKING" Requirements
- Smoking shall not be permitted inside or within 50 feet of the consumer fireworks retail sales stand / booth
- "NO SMOKING" signs in English and Spanish shall be conspicuously and permanently posted on all 4 exterior sides of the fireworks retail sales stand / booth. The lettering shall be at least 3 inches in height, and be against a color contrasting surface so it can be easily seen.
- The international symbol for "No Smoking" can be stenciled above the exit doors on the exterior of the fireworks retail sales stand / booth.
- Display of Fireworks in Booths
- Only fireworks obtained from a SNCFCC approved Wholesaler, which appear on the "approved" consumer fireworks product list of that calendar year as approved by the SNCFCC and/or the Authority Having Jurisdiction, shall be displayed in booths, for sale and on booth premises.
- Extra product storage shall be neat and orderly under the shelving.
- Matches, lighters and other sources of ignition shall not be located in the fireworks retail sales stand / booth or within 50 feet of booths.
- Portable generators shall be located not less than 20 feet from the consumer fireworks retail sales stand / booth.
- Portable "gasoline" generators shall be permitted provided the fuel tank quantity is limited to 2 gallons. (Class I flammable liquids)
- Portable "diesel or kerosene" generators shall be permitted provided the fuel tank quantity is limited to 5 gallons. (Class II and Class III Combustible Liquids)
- Generator fuels shall not be stored less than 20 feet from the consumer fireworks retail sales stand / booth, and shall be limited to not more than 3 gallons.
- Where the generator fuel storage is located greater than 50 feet from the consumer fireworks retail sales stand / booth, the quantity of such fuel shall not be limited.
- No motor vehicle or trailer parking within 10 feet of a fireworks retail sales stand / booth.
- No motor vehicle or trailer carrying or storing consumer fireworks shall be parked within 20 feet of a fireworks stand / booth, except when delivering, loading, or unloading fireworks or other merchandise and materials used, stored or displayed for sale in the fireworks retail sales stand / booth.
- Consumer fireworks retail sales stand / booth
- Storage Locations
- There shall be no storage permitted at any location unless the location is approved for that use by the Authority having Jurisdiction.
- In no case shall storage, for consumer fireworks, be permitted in residential neighborhoods, dwellings, garages, public ways or driveways.
- Inventory of Product
- Available inventory records shall be maintained in the fireworks retail sales stand / booth when there is product on site.
- The approved consumer fireworks product list shall be maintained in the fireworks retail sales stand / booth at all times when there is product on site.
- Approved permit packet shall be maintained on site at all times when there is product on site.
Southern Nevada Consumer Fireworks Code Committee (SNCFCC) Testing and Acceptance Procedures
Based on the requirements set forth in the APA (American Pyrotechnics Association) Standard 87-1
Based on the requirements set forth in the APA (American Pyrotechnics Association) Standard 87-1
- A minimum of 3 samples of each U. N. explosive class 1.4 G "consumer firework" devices due for renewal testing and new devices not previously tested and approved for sale by the SNCFCC shall be submitted to the SNCFCC for testing and acceptance no later than the 30th day of April of the current sales year. Items will be tested using the "Consumer Fireworks Product test Form". Passed or failed based criteria is outlined below and on the form.
- • Re-testing: any item which fails the initial test may be submitted for retesting. A minimum of 10 samples are required for the retesting and shall be retested using the "Consumer Fireworks Product Test Form" The item will be passed or failed based on the criteria outlined below and on the form.
- The SNCFCC may revoke prior acceptance of any fireworks item due to the changing in any way of the item by the manufacturer, wholesaler, retailer, or any other person(s).
- Every five (5) years the SNCC shall test all fireworks and develop and "approved for sale" list
- Handheld devices shall be tested annually
- All locally accepted fireworks shall have a California State Fire Marshal's "Safe and Sane" label printed on the item, or, in the case of small items, the item box shall have the State Fire Marshal's "Safe and Sane Seal" on it. NO Safe and Sane "Stickers" will be allowed.
- Each and every fireworks item labeled "Safe and Sane" shall be approved by DOT as a UN explosive class 1.4G "consumer fireworks" and shall be on the SNCFCC or the Authority Having Jurisdictions approved for sale fireworks list.
- Retailers shall display and sell consumer fireworks as they are intended and required to be sold per the wholesaler.
- Pyrotechnic leakage
- • The pyrotechnic chamber in the firework device shall be sealed in a manner that prevents leakage of the pyrotechnic composition during handling, transportation and normal operations.
- Firework devices that require a fuse shall comply with the following:
- • Utilize only a safety fuse that has been treated or coated in such a manner as to reduce the possibility of side ignition.
Exception: Devices such as which require a restricted orifice to operate and contain less than 6 grams of pyrotechnic composition. - • Utilize only a fuse which will burn at least 3 seconds but not more than 9 seconds before ignition of the device.
- • The fuse shall be securely attached so that it will support either the weight of the firework device plus 8 ounces (227g) of dead weight or double the weight of the device, whichever is less, without separation from the firework device for 30 seconds.
- • Utilize only a safety fuse that has been treated or coated in such a manner as to reduce the possibility of side ignition.
- The base of the bottom of the firework devices that are operated in a standing position shall have the minimum horizontal dimension or the diameter of the base equal to at least 1/3 of the height of the device including any base or cap affixed thereto. Bases must remain fully attached to the item during transportation, handling and normal operations.
- Firework devices which are intended to be hand-held and so labeled shall incorporate a handle at least 4 inches in length. Handles shall remain firmly attached during transportation, handling and full operation of the device, or shall consist of an integral section of the device at least 4 inches below the pyrotechnic chamber.Exception: Sparklers which are less than or equal to 10 inches in length shall have the handles greater than or equal to 3 inches in length.
- Ground spinning devices or any device that is designed to move shall operate within an area of a circle of 10 feet in diameter or less.
- The device shall not rise more than 1 foot into the air.
- Multi-color or multi-effect ground devices shall not exceed 10 seconds between effects.
- Drives in firework devices commonly known as "wheels" shall be securely attached to the device so that they will not come loose in transportation, handling, and normal operation. Wheel devices intend to operate in a fixed location shall be designed in such a manner that the axle remains attached to the device during normal operation.
- A nail for attachment to a suitable location shall be included with each device.
- Toy smoke devices shall be constructed so that they will neither burst nor produce external flame (excluding the fuse and first fire upon ignition) during normal operation.
- Toy smoke and flitter devices shall not be of such color and configuration so as to be confused with banned fireworks including but not limited to: M-80 salutes, silver salutes, cherry bombs, etc.
- Toy smoke devices shall not incorporate plastic as an exterior material if the pyrotechnic composition comes in direct contact with the plastic.
- Burnout, blowout and meltdown
- • Burnout — the unintended escape of flame though the wall of a pyrotechnic chamber during use
- • Blowout — the unintended release of pressure at the other than the intended orifice
- • Meltdown — the continued burning of a pyrotechnic device after the intended effect has concluded. (Cool down time: 30 minutes per AFSL requirements)
- Residual Burning Test
- • Use a thermal detector to note the temperature on the test form during ignition. Place the detector 11 inches from top of product while getting temperature reading.
- • After the 30 min cool down period, note the temperature on the test form holding the detector 11 inches from top of product.
- • If the internal temperature of the product tested is above 250°F (121°C), the product is recorded as a failure
- Duds
- • Duds — devices which fail to ignite and perform their intended effect, or which the fuse initially ignites but fails to ignite the device.
- Novelties are defined as U.N. class 1.4s or are deregulated and NOT classified as hazardous materials by DOT on the basis of specific test results. Novelty items are not tested or approved by SNCC and are legal to sell year round.
- • Novelties Include:
- • Party Poppers — Small plastic or paper devices containing not more than 16 mg of explosive composition that is friction sensitive. A string protruding from the device is usually pulled to ignite it. This device expels non-flammable paper streamers and/or similar products and produces a small report.
- • Snappers — Small, paper-wrapped device containing not more than 1.0mg of explosive composition coated on small bits of sand, and package with sawdust in individual containers of not more than 50 units. When dropped the device explodes, producing a small report.
- • Snake, Glow Worm — Pressed pellet of not more than 2g of pyrotechnic composition and packaged in retail packages of not more than 25 units that produces as the primary effect a snake- like ash upon burning. The ash expands in length as the pellet burns.
- • Sparklers (#10 or less) — Wire or stick coated with pyrotechnic composition which may not exceed 100 g per item, that produces a shower of sparks upon ignition.
- • Toy Caps — Toy plastic or paper caps for toy pistols in sheets, strips, rolls, or individual caps, containing not more than an average of 16 mg of explosive composition per cap. Toy Caps are described as fireworks UN0336 and classed as 1.4G.
- • Other Novelties — Devices intended to produce unique visual or audible effects and containing 50mg or less of explosive composition and limited amounts of other pyrotechnic composition. Examples include: Cigarette loads, trick matches, explosive auto alarms and other trick noise makers.
- • Novelties Include:
- Firework devices shall not contain any of the following:
- • Arsenic sulfide, arsenates, or arsenite.
- • Boron
- • Chlorates
- • Exceptions:
- a. In colored smoke mixtures to which an equal or greater amount of sodium bicarbonate is included.
- b. In caps
- c. In those small items wherein the total power content does not exceed 4g of which not greater than 15% (or 600mg) is potassium, sodium, or barium chloride.
- • Exceptions:
- • Gallate or gallic acid
- • Magnesium
- • Exception:
- a. Magnesium / aluminum alloys, aka "magnalium"
- • Exception:
- • Mercury salts
- • Phosphorus (red or white)
- • Exception:
- a. Red phosphorus is permitted in caps
- • Exception:
- • Picrates or picric acid
- • Thiocyanates
- • Titanium
- • Exception:
- a. Particle sizes greater than 100-mesh
- • Exception:
- • Zirconium