CALIFORNIA RESIDENTIAL CODE — MATRIX ADOPTION TABLE
CHAPTER 44 — REFERENCED STANDARDS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user.
See Chapter 1 for state agency authority and building applications.)
Adopting agency BSC BSC-CG SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
1 2 1/AC AC SS SS/CC 1 2 3 4
Adopt entire chapter
Adopt entire chapter as amended (amended sections listed below) X X
Adopt only those sections that are listed below
Chapter / Section
ANSI X
ASTM X
IBC-15 X
IPC-15 X
IPSDC-15 X
ICC X
NFPA X
SFM X
UBC X


Notwithstanding California laws and regulations, these referenced standards shall be applicable only to those California Residential Code sections that are adopted.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R102.4.

AAMA

American Architectural Manufacturers Association
1827 Walden Office Square, Suite 550
Schaumburg IL 60173
Standard
reference
number
TitleReferenced
in code
section number

AAMA/WDMA/CSA
101/I.S.2/A440—11

North American Fenestration Standards/Specifications for Windows, Doors and Skylights

R308.6.9, R609.3, N1102.4.3

450—10

Voluntary Performance Rating Method for Mulled Fenestration Assemblies

R609.8

506—11

Voluntary Specifications for Hurricane Impact and Cycle Testing of Fenestration Products

R609.6.1

711—13

Voluntary Specification for Self-adhering Flashing Used for Installation of Exterior Wall Fenestration Products

R703.4

712—11

Voluntary Specification for Mechanically Attached Flexible Flashing

R703.4

714—12

Voluntary Specification for Liquid Applied Flashing Used to Create a Water-resistive Seal around Exterior Wall Openings in Buildings

R703.4

AAMA/NPEA/
NSA 2100—12

Specifications for Sunrooms

R302.2.1.1

ACI

American Concrete Institute
38800 Country Club Drive
Farmington Hills MI 48331
Standard
reference
number
TitleReferenced
in code
section number

332—14

Code Requirements for Residential Concrete Construction

R402.2, R403.1, R404.1.3, R404.1.3.4, R404.1.4.2, R506.1

530—13

Building Code Requirements for Masonry Structures

R404.1.2, R606.1, R606.1.1, R606.12.1, R606.12.2.3.2, R606.12.2.3.1, R703.12

R606.12.3.1530.1—13

Specification for Masonry Structures

R404.1.2, R606.1, R606.1.1, R606.2.9, R606.2.12, R606.12.1, R606.12.2.3.2, R606.12.3.1, 703.12

ACCA

Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington VA 22206
Standard
reference
number
TitleReferenced
in code
section number

Manual D—2011

Residential Duct Systems

M1601.1, M1602.2

Manual J—2011

Residential Load Calculation—Eighth Edition

N1103.6, M1401.3

Manual S—13

Residential Equipment Selection

N1103.6, M1401.3

AISI

American Iron and Steel Institute
25 Massachusetts Avenue, NW Suite 800
Washington DC 20001
Standard
reference
number
TitleReferenced
in code
section number

AISI S100—12

North American Specification for the Design of Cold-formed Steel Structural Members, 2012

R505.1.3, R603.6, R608.9.2, R608.9.3, R804.3.6

AISI S200—12

North American Standard for Cold-formed Steel Framing—General Provisions 2012

R702.3.3

AISI S220—11

North American Standard for Cold-formed Steel Framing—Nonstructural Members

R702.3.3

AISI S230—07/S3-12 (2012)

Standard for Cold-formed Steel Framing—Prescriptive Method for One- and Two-family Dwellings, 2007 with Supplement 3, dated 2012 (Reaffirmed 2012)

R301.1.1, R301.2.1.1, R301.2.2.3.1, R301.2.2.3.5, R603.6, R603.9.4.1, R603.9.4.2, R608.9.2, R608.9.3, Figure 608.9(11), R608.10

AMCA

Air Movement and Control Association
300 West University
Arlington Heights IL 60004
Standard
reference
number
TitleReferenced
in code
section number

ANSI/AMCA 210-ANSI/ASHRAE 51—07

Laboratory Methods of Testing Fans for Aerodynamic Performance Rating

Table M1506.2

AMD

Association of Millwork Distributors Standards
10047 Robert Trent Parkway
New Port Richey FL 34655-4649
Standard
reference
number
TitleReferenced
in code
section number

AMD 100—2013

Structural Performance Ratings of Side Hinged Exterior Door Systems and Procedures for Component Substitution

R609.3

ANCE

Association of the Electric Sector
Av. Lázaro Cardenas No. 869
Col. Nueva Industrial Vallejo
México D.F. C.P. 07700
Standard
reference
number
TitleReferenced
in code
section number

UL/CSA/ANCE 60335-2—2012

Standard for Household and Similar Electric Appliances, Part 2: Particular Requirements for Motor-compressors

M1403.1, M1412.1, M1413.1

ANSI

American National Standards Institute
25 West 43rd Street, Fourth Floor
New York NY 10036
Standard
reference
number
TitleReferenced
in code
section number

A108.1A—99

Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar

R702.4.1

A108.1B—99

Installation of Ceramic Tile, Quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex Portland Mortar

R702.4.1

A108.4—99

Installation of Ceramic Tile with Organic Adhesives or Water-Cleanable Tile-setting Epoxy Adhesive

R702.4.1

A108.5—99

Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex Portland Cement Mortar

R702.4.1

A108.6—99

Installation of Ceramic Tile with Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy

R702.4.1

A108.11—99

Interior Installation of Cementitious Backer Units

R702.4.1

A118.1—99

American National Standard Specifications for Dry-set Portland Cement Mortar

R702.4.1

A118.3—99

American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy, and Water-cleanable Tile-setting Epoxy Adhesive

R702.4.1

A118.4—99

American National Standard Specifications for Latex-Portland Cement Mortar

R606.2.10

A118.10—99

Specification for Load-bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile and Dimension Stone Installation

P2709.2, P2709.2.4

A136.1—99

American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile

R702.4.1

A137.1—2012

American National Standard Specifications for Ceramic Tile

R702.4.1

LC1/CSA 6.26—13

Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST)

G2414.5.3

LC4/CSA 6.32—12

Press-connect Metallic Fittings for Use in Fuel Gas Distribution Systems

G2414.10.2

S3.41

American National Standard Audible Evacuation Signal

R325.5.2.1

Z21.1—2010

Household Cooking Gas Appliances

G2447.1

Z21.5.1/CSA 7.1—14

Gas Clothes Dryers—Volume I—Type I Clothes Dryers

G2438.1

Z21.8—94 (R2002)

Installation of Domestic Gas Conversion Burners

G2443.1

Z21.10.1/CSA 4.1—12

Gas Water Heaters—Volume I—Storage Water Heaters with Input Ratings of 75,000 Btu per hour or Less

G2448.1

Z21.10.3/CSA 4.3—11

Gas Water Heaters—Volume III—Storage Water Heaters with Input Ratings above 75,000 Btu per hour, Circulating and Instantaneous

G2448.1

Z21.11.2—11

Gas-fired Room Heaters—Volume II—Unvented Room Heaters

G2445.1

Z21.13/CSA 4.9—11

Gas-fired Low-pressure Steam and Hot Water Boilers

G2452.1

Z21.15/CSA 9.1—09

Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves

Table G2420.1.1

Z21.22—99 (R2003)

Relief Valves for Hot Water Supply Systems—with Addenda Z21.22a—2000 (R2003) and 21.22b—2001 (R2003)

P2804.2, P2804.7

Z21.24/CGA 6.10—06

Connectors for Gas Appliances

G2422.1

Z21.40.1/CSA 2.91—96 (R2011)

Gas-fired, Heat-activated Air-conditioning and Heat Pump Appliances

G2449.1

Z21.40.2/CSA 2.92—96 (R2011)

Air-conditioning and Heat Pump Appliances (Thermal Combustion)

G2449.1

Z21.42—2014

Gas-fired Illuminating Appliances

G2450.1

Z21.47/CSA 2.3—12

Gas-fired Central Furnaces

G2442.1

Z21.50/CSA 2.22—12

Vented Gas Fireplaces

G2434.1

Z21.56/CSA 4.7—13

Gas-fired Pool Heaters

G2441.1

Z21.58—95/CSA 1.6—13

Outdoor Cooking Gas Appliances

G2447.1

Z21.60/CSA 2.26—12

Decorative Gas Appliances for Installation in Solid Fuel-burning Fireplaces

G2432.1

Z21.75/CSA 6.27—07

Connectors for Outdoor Gas Appliances and Manufactured Homes

G2422.1

Z21.80—11

Line Pressure Regulators

G2421.1

ANSI/CSA America

Stationary Fuel Cell Power Systems

M1903.1

FCI—12 Z21.84—12

Manually Listed, Natural Gas Decorative Gas Appliances for Installation in Solid Fuel-burning Fireplaces

G2432.1, G2432.2

Z21.86—08

Gas-fired Vented Space Heating Appliances

G2436.1, G2437.1, G2446.1

Z21.88/CSA 2.33—14

Vented Gas Fireplace Heaters

G2435.1

Z21.91—07

Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters

G2445.7.1

Z21.97—12

Outdoor Decorative Appliances

G2454.1

Z83.6—90 (R1998)

Gas-fired Infrared Heaters

G2451.1

Z83.8/CSA 2.6—09

Gas-fired Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces

G2444.1

Z83.19—01 (R2009)

Gas-fuel High-intensity Infrared Heaters

G2451.1

Z83.20—08

Gas-fired Low-intensity Infared Heaters Outdoor Decorative Appliances

G2451.1

Z97.1—2014

Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test

R308.1.1, R308.3.1

APA

APA—The Engineered Wood Association
7011 South 19th
Tacoma WA 98466
Standard
reference
number
TitleReferenced
in code
section number

ANSI/A190.1—12

Structural Glued-laminated Timber

R502.1.3, R602.1.3, R802.1.2

ANSI/APA PRP 210—08

Standard for Performance-rated Engineered Wood Siding

R604.1, Table R703.3(1), R703.3.3

ANSI/APA PRG 320—2012

Standard for Performance-rated Cross Laminated Timber

R502.1.6, R602.1.6, R802.1.6

ANSI/APA PRR 410—2011

Standard for Performance-rated Engineered Wood Rim Boards

R502.1.7, R602.1.7, R802.1.7

APA E30—11

Engineered Wood Construction Guide

Table R503.2.1.1(1), R503.2.2, R803.2.2, R803.2.3

ASCE/SEI

American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston VA 20191
Standard
reference
number
TitleReferenced
in code
section number

24—14

Flood-resistant Design and Construction

R301.2.4, R301.2.4.1, R322.1, R322.1.1, R322.1.6, R322.1.9, R322.2.2, R322.3.3

32—01

Design and Construction of Frost-protected Shallow Foundations

R403.1.4.1

ASHRAE

American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta GA 30329
Standard
reference
number
TitleReferenced
in code
section number

ASHRAE—2013

ASHRAE Handbook of Fundamentals

N1102.1.5, Table N1105.5.2(1), P3001.2, P3101.4

ASHRAE 193—2010

Method of Test for Determining Air Tightness of HVAC Equipment

N1103.3.2.1

34—2013

Designation and Safety Classification of Refrigerants

M1411.1

ASME

American Society of Mechanical Engineers
Three Park Avenue
New York NY 10016-5990
Standard
reference
number
TitleReferenced
in code
section number

ASME/A17.1/CSA B44—2013

Safety Code for Elevators and Escalators

R321.1

A18.1—2008

Safety Standard for Platforms and Stairway Chair Lifts

R321.2

A112.1.2—2004

Air Gaps in Plumbing Systems

P2717.1, Table P2902.3, P2902.3.1

A112.1.3—2000 (Reaffirmed 2011)

Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances

Table P2701.1, P2717.1, Table P2902.3, P2902.3.1

A112.3.1—2007

Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum Applications Above and Below Ground

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, Table P3302.1

A112.3.4—2013/CSA B45.9—13

Macerating Toilet Systems and Related Components

Table P2701.1, P3007.5

A112.4.1—2009

Water Heater Relief Valve Drain Tubes

P2804.6.1

A112.4.2—2009

Water-closet Personal Hygiene Devices

P2722.5

A112.4.3—1999 (R2010)

Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System

P3003.14

A112.4.14—2004 (R2010)

Manually Operated, Quarter-turn Shutoff Valves for Use in Plumbing Systems

Table P2903.9.4

A112.6.1M—1997 (R2008)

Floor-affixed Supports for Off-the-floor Plumbing Fixtures for Public Use

Table P2701.1, P2702.4

A112.6.2—2000 (R2010)

Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks

Table P2701.1, P2702.4

A112.6.3—2001 (R2007)

Floor and Trench Drains

Table P2701.1

A112.14.1—03 (Reaffirmed 2008)

Backwater Valves

P3008.2

A112.18.1—2012/CSA B125.1—2012

Plumbing Supply Fittings

Table P2701.1, P2708.5, P2722.1, P2722.3, P2727.2, P2902.2, Table P2903.9.4

A112.18.2—2011/CSA B125.2—2011

Plumbing Waste Fittings

Table P2701.1, P2702.2

A112.18.3—2002 (Reaffirmed 2008)

Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings

P2708.5, P2722.3

A112.18.6/CSA B125.6—2009

Flexible Water Connectors

P2906.7

A112.19.1—2013/CSA B45.2—2013

Enameled Cast-iron and Enameled Steel Plumbing Fixtures

Table P2701.1, P2711.1

A112.19.2—2013/CSA B45.1—2013

Ceramic Plumbing Fixtures

Table P2701.1, P2705.1, P2711.1, P2712.1, P2712.2, P2712.9

A112.19.3—2008/CSA B45.4—08 (R2013)

Stainless Steel Plumbing Fixtures

Table P2701.1, P2705.1, P2711.1, P2712.1

A112.19.5—2011/CSA B45.15—2011

Flush Valves and Spuds for Water-closets, Urinals and Tanks

Table P2701.1

A112.19.7/2012 CSA B45.10—2012

Hydromassage Bathtub Systems

Table P2701.1

A112.19.12—2006

Wall-mounted and Pedestal-mounted, Adjustable and Pivoting Lavatory and Sink Carrier Systems

Table P2701.1, P2711.4, P2714.2

A112.19.14—2006 (R2011)

Six-Liter Water Closets Equipped with Dual Flushing Device

P2712.1

A112.19.15—2005

Bathtub/Whirlpool Bathtubs with Pressure-sealed Doors

Table P2701.1, P2713.2

A112.36.2m—1991 (R2008)

Cleanouts

P3005.2.10.2

B1.20.1—1983 (R2006)

Pipe Threads, General-purpose (Inch)

G2414.9, P3003.6.4, P3003.17.1, P3003.9.3

B16.3—2011

Malleable-iron-threaded Fittings, Classes 150 and 300

Table P2906.6

B16.4—2011

Gray-iron-threaded Fittings

Table P2906.6, Table P3002.3

B16.9—2007

Factory-made, Wrought-steel Buttwelding Fittings

Table P2906.6

B16.11—2011

Forged Fittings, Socket-welding and Threaded

Table P2906.6

B16.12—2009

Cast-iron-threaded Drainage Fittings

Table P3002.3

B16.15—2011

Cast-bronze-threaded Fittings

Table P2906.6, Table P3002.3

B16.18—2012

Cast-copper-alloy Solder Joint Pressure Fittings

Table P2906.6, Table P3002.3

B16.22—2001 (R2010)

Wrought-copper and Copper-alloy Solder Joint Pressure Fittings

Table P2906.6, Table P3002.3

B16.23—2002 (R2011)

Cast-copper-alloy Solder Joint Drainage Fittings (DWV)

Table P3002.3

B16.26—2011

Cast-copper-alloy Fittings for Flared Copper Tubes

Table P2906.6, Table P3002.3

B16.28—1994

Wrought-steel Buttwelding Short Radius Elbows and Returns

Table P2906.6

B16.29—2012

Wrought-copper and Wrought-copper-alloy Solder Joint Drainage Fittings (DWV)

Table P3002.3

B16.33—2012

Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 125 psig (Sizes 1/2 through 2)

Table G2420.1.1

B16.34—2009

Valves—Flanged, Threaded and Welding End

Table P2903.9.4

B16.44—2002 (Reaffirmed 2007)

Manually Operated Metallic Gas Valves for Use in Above-ground Piping Systems up to 5 psi

Table G2420.1.1

B16.51—2011

Copper and Copper Alloy Press-Connect Pressure Fittings

Table 2906.6

B36.10M—2004

Welded and Seamless Wrought-steel Pipe

G2414.4.2

BPVC—2010/2011 addenda

ASME Boiler and Pressure Vessel Code (2007 Edition)

M2001.1.1, G2452.1

CSD-1—2011

Controls and Safety Devices for Automatically Fired Boilers

M2001.1.1, G2452.1

ASSE 1016/ASME 112.1016/CSA B125.16—2011

Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations

Table P2701.1, P2708.4, P2722.2

ASSE

American Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake, OH 44145
Standard
reference
number
TitleReferenced
in code
section number

1001—2008

Performance Requirements for Atmospheric-type Vacuum Breakers

Table P2902.3, P2902.3.2

1002—2008

Performance Requirements for Anti-siphon Fill Valves for Water Closet Flush Tank

Table P2701.1, Table P2902.3, P2902.4.1

1003—2009

Performance Requirements for Water-pressure-reducing Valves for Domestic Water Distribution Systems

P2903.3.1

1008—2006

Performance Requirements for Plumbing Aspects of Residential Food Waste Disposer Units

Table P2701.1

1010—2004

Performance Requirements for Water Hammer Arresters

P2903.5

1011—2004

Performance Requirements for Hose Connection Vacuum Breakers

Table P2902.3, P2902.3.2

1012—2009

Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent

Table P2902.3, P2902.3.3, P2902.5.1, P2902.5.5.3

1013—2009

Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Principle Fire Protection Backflow Preventers

Table P2902.3, P2902.3.5, P2902.5.1, P2902.5.5.3

1015—2009

Performance Requirements for Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies

Table P2902.3, P2902.3.6

ASSE 1016/ASME 112.1016/CSA B125.16—2011

Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations

Table P2701.1, P2708.4, P2722.2

1017—2010

Performance Requirements for Temperature-actuated Mixing Valves for Hot Water Distribution Systems

P2724.1, P2802.1, P2803.2

1018—2010

Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied

P3201.2.1, P3201.2.2

1019—2010

Performance Requirements for Freeze-resistant, Wall Hydrants, Vacuum Breaker, Draining Types

Table P2701.1, P2902.3.2

1020—2004

Performance Requirements for Pressure Vacuum Breaker Assembly

Table P2902.3, P2902.3.4

1023—2010

Performance Requirements for Hot Water Dispensers, Household-storage-type—Electrical

Table P2701.1

1024—2004

Performance Requirements for Dual Check Backflow Preventers, Anti-siphon-type, Residential Applications

Table P2902.3, P2902.3.7

1035—2008

Performance Requirements for Laboratory Faucet Backflow Preventers

Table P2902.3, P2902.3.2

1037—2010

Performance Requirements for Pressurized Flushing Devices (Flushometer) for Plumbing Fixtures

Table P2701.1

1044—2010

Performance Requirements for Trap Seal Primer Devices Drainage Types and Electronic Design Types

P3201.2.3

1047—2009

Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies

Table P2902.3, P2902.3.5

1048—2009

Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies

Table P2902.3, P2902.3.6

1050—2009

Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems

P3114.1

1051—2009

Performance Requirements for Individual and Branch-type Air Admittance Valves for Plumbing Drainage Systems

P3114.1

1052—2004

Performance Requirements for Hose Connection Backflow Preventers

Table P2701.1, Table P2902.3, P2902.3.2

1056—2010

Performance Requirements for Spill-resistant Vacuum Breakers

Table P2902.3, P2902.3.4

1060—2006

Performance Requirements for Outdoor Enclosures for Fluid-conveying Components

P2902.6.1

1061—2010

Performance Requirements for Removable and Nonremovable Push Fit Fittings

Table P2906.6

1062—2006

Performance Requirements for Temperature-actuated, Flow Reduction (TAFR) Valves for Individual Supply Fittings

Table P2701.1, P2724.2

1066—2009

Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings

P2722.4

1070—2004

Performance Requirements for Water-temperature-limiting Devices

P2713.3, P2721.2, P2724.1

1072—07

Performance Requirements for Barrier-type Floor Drain Trap Seal Protection Devices

P3201.2.4

ASTM

ASTM International
100 Barr Harbor Drive
West Conshohocken PA 19428
Standard
reference
number
TitleReferenced
in code
section number

A36/A36M—08

Specification for Carbon Structural Steel

R606.15, R608.5.2.2

A53/A53M—12

Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless

R407.3, Table M2101.1, G2414.4.2, Table P2906.4, Table P2906.5, Table P3002.1(1)

A74—13A

Specification for Cast-iron Soil Pipe and Fittings

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, P3005.2.6, Table P3302.1

A106/A 106M—11

Specification for Seamless Carbon Steel Pipe for High-temperature Service

Table M2101.1, G2414.4.2

A126—(2009)

Gray Iron Castings for Valves, Flanges and Pipe Fittings

Table P2903.9.4

A153/A 153M—09

Specification for Zinc Coating (Hot Dip) on Iron and Steel Hardware

R317.3, Table R606.3.4.1, 703.6.3, R905.7.5, R905.8.6

A167—99 (2009)

Specification for Stainless and Heat-resisting Chromium-nickel Steel Plate, Sheet and Strip

Table R606.3.4.1

A240/A 240M—13A

Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications

Table R905.10.3(1)

A254—97 (2007)

Specification for Copper Brazed Steel Tubing

Table M2101.1, G2414.5.1

A307—12

Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength

R608.5.2.2

A312/A312M—13A

Specification for Seamless, Welded and Heavily Cold Worked Austenitic Stainless Steel Pipes

Table P2906.4, Table P2906.5, Table P2906.6, P2905.12.2

A463/A463M—10

Standard Specification for Steel Sheet, Aluminum-coated by the Hot-dip Process

Table R905.10.3(2)

A539—99

Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines

M2202.1

A615/A615M—12

Specification for Deformed and Plain Billet-steel Bars for Concrete Reinforcement

R402.3.1, R403.1.3.5.1, R404.1.3.3.7.1, R608.5.2.1

A641/A641M—09a

Specification for Zinc-coated (Galvanized) Carbon Steel Wire

Table R606.3.4.1

A653/A653M—11

Specification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-iron Alloy-coated Galvanized) by the Hot-dip Process

R317.3.1, R505.2.2, R603.2.2, Table R606.3.4.1, R608.5.2.3, R804.2.2, R804.2.3, Table R905.10.3(1), Table R905.10.3(2), M1601.1.1

A706/A706M—09B

Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement

R402.3.1, R403.1.3.5.1, R404.1.3.3.7.1, R608.5.2.1

A755/A755M—2011

Specification for Steel Sheet, Metallic Coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products

Table R905.10.3(2)

A778—01 (2009e1)

Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products

Table P2905.4, Table P2905.5, Table P2905.6

A792/A792M—10

Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process

R505.2.2, R603.2.2, R608.5.2.3, R804.2.2, Table 905.10.3(2)

A875/A875M—13

Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the Hot-dip Process

R608.5.2.3, Table R905.10.3(2)

A888—13A

Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Application

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, Table P3302.1

A924/A924M—13

Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-Dip Process

Table R905.10.3(1)

A996/A996M—2009b

Specifications for Rail-steel and Axle-steel Deformed Bars for Concrete Reinforcement

Table R404.1.2(9), R402.3, R403.1.3.5.1, R404.1.3.3.7.1, R608.5.2.1, Table R608.5.4(2)

A1003/A1003M—13A

Standard Specification for Steel Sheet, Carbon, Metallic and Nonmetallic-coated for Cold-formed Framing Members

R505.2.1, R505.2.2, R603.2.1, R603.2.2, R804.2.1

B32—08

Specification for Solder Metal

P3003.6.3

B42—10

Specification for Seamless Copper Pipe, Standard Sizes

Table M2101.1, Table P2906.4, Table P2906.5, Table P3002.1(1)

B43—09

Specification for Seamless Red Brass Pipe, Standard Sizes

Table M2101.1, Table P2906.4, Table P2906.5, Table P3002.1(1)

B75—11

Specification for Seamless Copper Tube

Table M2101.1, Table P2905.4, Table P2906.5, Table P3002.1(1), Table P3002.1(2), Table P3002.2

B88—09

Specification for Seamless Copper Water Tube

Table M2101.1, G2414.5.2, Table, P2906.4, Table P2905.6, Table P3002.1(1), Table P3002.1(2), Table P3002.2

B101—12

Specification for Lead-coated Copper Sheet and Strip for Building Construction

Table R905.2.8.2, Table R905.10.3(1)

B135—10

Specification for Seamless Brass Tube

Table M2101.1

B209—10

Specification for Aluminum and Aluminum-alloy Sheet and Plate

Table 905.10.3(1)

B227—10

Specification for Hard-drawn Copper-clad Steel Wire

R606.15

B251—10

Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube

Table M2101.1, Table P2906.4, Table P2906.5, Table P3002.1(1), Table P3002.1(2), Table P3002.2

B302—12

Specification for Threadless Copper Pipe, Standard Sizes

Table M2101.1, Table P2906.4, Table P2906.5, Table P3002.1(1)

B306—09

Specification for Copper Drainage Tube (DWV)

Table M2101.1, Table P3002.1(1), Table P3002.1(2)

B370—12

Specification for Copper Sheet and Strip for Building Construction

Table R905.2.8.2, Table R905.10.3(1), Table P2701.1

B447—12a

Specification for Welded Copper Tube

Table P2906.4, Table P2906.5

B695—04 (2009)

Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel

R317.3.1, R317.3.3

B813—10

Specification for Liquid and Paste Fluxes for Soldering Applications of Copper and Copper Alloy Tube

Table M2101.1, M2103.3, P2906.14, P3003.6.3

B828—02 (2010)

Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings

M2103.3, P2906.14, P3003.6.3

C4—2009

Specification for Clay Drain Tile and Perforated Clay Drain Tile

Table P3302.1

C5—10

Specification for Quicklime for Structural Purposes

R702.2.1

C14—11

Specification for Non-reinforced Concrete Sewer, Storm Drain and Culvert Pipe

Table P3002.2

C22/C22M—00 (2010)

Specification for Gypsum

R702.2.1, R702.3.1

C27—98 (2008)

Specification for Standard Classification of Fireclay and High-alumina Refractory Brick

R1001.5

C28/C28M—10

Specification for Gypsum Plasters

R702.2.1

C33/C33M—13

Specification for Concrete Aggregates

R403.4.1

C34—12

Specification for Structural Clay Load-bearing Wall Tile

Table R301.2(1), R606.2.2

C35/C35M—1995 (2009)

Specification for Inorganic Aggregates for Use in Gypsum Plaster

R702.2.1

C55—2011

Specification for Concrete Building Brick

R202, Table R301.2(1), R606.2.1

C56—12

Standard Specification for Structural Clay Nonloadbearing Tile

R606.2.2

C59/C59M—00 (2011)

Specification for Gypsum Casting Plaster and Molding Plaster

R702.2.1

C61/C61M—00 (2011)

Specification for Gypsum Keene's Cement

R702.2.1

C62—13

Standard Specification for Building Brick (Solid Masonry Units Made from Clay or Shale)

R202, Table R301.2(1), R606.2.2

C73—10

Specification for Calcium Silicate Face Brick (Sand Lime Brick)

R202, Table R301.2(1), R606.2.1

C76—13A

Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe

Table P3002.2

C90—13

Specification for Load-bearing Concrete Masonry Units

Table R301.2(1), 606.2.1

C91—12

Specification for Masonry Cement

R702.2.2

C94/C94M—13

Standard Specification for Ready-mixed Concrete

R404.1.3.3.2, R608.5.1.2

C126—13

Standard Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units

R606.2.2

C129—11

Specification for Nonload-bearing Concrete Masonry Units

Table R301.2(1)

C143/C143M—12

Test Method for Slump of Hydraulic Cement Concrete

R404.1.3.3.4, R608.5.1.9

C145—85

Specification for Solid Load-bearing Concrete Masonry Units

R202, Table R301.2(1)

C150—12

Specification for Portland Cement

R608.5.1.1, R702.2.2

C199—84 (2011)

Test Method for Pier Test for Refractory Mortar

R1001.5, R1001.8, R1003.12

C203—05a (2012)

Standard Test Methods for Breaking Load and Flexural Properties of Block-type Thermal Insulation

Table R610.3.1

C207—06 (2011)

Specification for Hydrated Lime for Masonry Purposes

Table R606.2.7

C208—12

Specification for Cellulosic Fiber Insulating Board

R602.1.10, Table R602.3(1), Table R906.2

C212-10

Standard Specification for Structural Clay Facing Tile

R602.2.2

C216—13

Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)

R202, Table R301.2(1), R606.2.2

C270—12a

Specification for Mortar for Unit Masonry

R606.2.7, R606.2.10

C272/C272M—12

Standard Test Method for Water Absorption of Core Materials for Sandwich Constructions

Table R610.3.1

C273/C273M—11

Standard Test Method for Shear Properties of Sandwich Core Materials

Table R610.3.1

C315—07 (2011)

Specification for Clay Flue Liners and Chimney Pots

R1001.8, R1003.11.1, Table R1003.14(1), G2425.12

C406/C406M—2010

Specifications for Roofing Slate

R905.6.4

C411—11

Test Method for Hot-surface Performance of High-temperature Thermal Insulation

M1601.3

C425—04 (2009)

Specification for Compression Joints for Vitrified Clay Pipe and Fittings

Table P3002.2, P3003.10, P3003.13

C443—12

Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets

P3003.5, P3003.13

C475/C475M—12

Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard

R702.3.1

C476—10

Specification for Grout for Masonry

R606.2.11

C503—10

Standard Specification for Marble Dimension Stone

R606.2.4

C514—04 (2009)el

Specification for Nails for the Application of Gypsum Wallboard

R702.3.1

C552—12b

Standard Specification for Cellular Glass Thermal Insulation

Table R906.2

C557—03 (2009)e01

Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing

R702.3.1

C564—12

Specification for Rubber Gaskets for Cast Iron Soil Pipe and Fittings

P3003.4.2, P3003.4.3, P3003.13

C568—10

Standard Specification for Limestone Dimension Stone

R606.2.4

C578—12b

Specification for Rigid, Cellular Polystyrene Thermal Insulation

R316.8, R403.3, R610.3.1, R703.11.2.1, Table R703.15.1, Table R703.15.2, Table R703.16.1, Table R703.16.2, Table R906.2

C587—04 (2009)

Specification for Gypsum Veneer Plaster

R702.2.1

C595/C595M—13

Specification for Blended Hydraulic Cements

R608.5.1.1, R702.2.2

C615/C615M—11

Standard Specification for Granite Dimension Stone

R606.2.4

C616/C615M—10

Standard Specification for Quartz Dimension Stone

R606.2.4

C629—10

Standard Specification for Slate Dimension Stone

R606.2.4

C631—09

Specification for Bonding Compounds for Interior Gypsum Plastering

R702.2.1

C645—13

Specification for Nonstructural Steel Framing Members

R702.3.3

C652—13

Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale)

R202, Table R301.2(1), R606.2.2

C685/C685M—11

Specification for Concrete Made by Volumetric Batching and Continuous Mixing

R404.1.3.3.2, R608.5.1.2

C700—13

Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength and Perforated

Table P3002.2, Table P3002.3, Table P3302.1

C728—05 (2013)

Standard Specification for Perlite Thermal Insulation Board

Table R906.2

C744—11

Standard Specification for Prefaced Concrete and Calcium Silicate Masonry Units

R606.2.1

C836/C836M—12

Specification for High Solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course

R905.15.2

C843—99 (2012)

Specification for Application of Gypsum Veneer Plaster

R702.2.1

C844—04 (2010)

Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster

R702.2.1

C847—12

Specification for Metal Lath

R702.2.1, R702.2.2

C887—05 (2010)

Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar

R406.1, R606.2.8

C897—05 (2009)

Specification for Aggregate for Job-mixed Portland Cement-based Plasters

R702.2.2

C920—11

Standard Specification for Elastomeric Joint Sealants

R406.4.1

C926—13

Specification for Application of Portland Cement-based Plaster

R702.2.2, R702.2.2.1, R703.7, R703.7.2.1, R703.7.4

C933—13

Specification for Welded Wire Lath

R702.2.1, R702.2.2

C946—10

Standard Practice for Construction of Dry-Stacked, Surface-Bonded Walls

R606.2.8

C954—11

Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 in (0.84 mm) or to 0.112 in. (2.84 mm) in Thickness

R505.2.5, R603.2.5, R702.3.5.1, R804.2.5

C955—11C

Specification for Load-bearing (Transverse and Axial) Steel Studs, Runners (Tracks), and Bracing or Bridging for Screw Application of Gypsum Panel Products and Metal Plaster Bases

R702.3.3

C957—10

Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Integral Wearing Surface

R905.15.2

C1002—07

Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases

R702.3.1, R702.3.5.1

C1029—13

Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation

R905.14.2

C1032—06 (2011)

Specification for Woven Wire Plaster Base

R702.2.1, R702.2.2

C1047—10a

Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base

R702.2.1, R702.2.2, R702.3.1

C1063—12D

Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster

R702.2.2, R703.7

C1088—13

Standard Specification for Thin Veneer Brick Units Made from Clay or Shale

R606.2.2

C1107/C1107M—13

Standard Specification for Packaged Dry, Hydraulic-cement Grout (Nonshrink)

R402.3.1

C1116/C116M—10A

Standard Specification for Fiber-reinforced Concrete and Shotcrete

R402.3.1

C1157—11/C1157M—11

Standard Performance Specification for Hydraulic Cement

R608.5.1.1

C1167—11

Specification for Clay Roof Tiles

R905.3.4

C1173—10e1

Specification for Flexible Transition Couplings for Underground Piping Systems

P3003.3.1, P3003.5, P3003.6.1, P3003.10.1, P3003.12.1, P3003.12.2, P3003.13

C1177/C1177M—08

Specification for Glass Mat Gypsum Substrate for Use as Sheathing

R702.3.1, Table 906.2

C1178/C1178M—11

Specification for Glass Mat Water-resistant Gypsum Backing Panel

R702.3.1, R702.3.7, Table R702.4.2

C1186—08 (2012)

Specification for Flat Nonasbestos Fiber Cement Sheets

R703.10.1, R703.10.2

C1261—10

Specification for Firebox Brick for Residential Fireplaces

R1001.5, R1001.8

C1277—12

Specification for Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings

P3003.4.3

C1278/C1278M—07a (2011)

Specification for Fiber-reinforced Gypsum Panels

R702.3.1, R702.3.7, Table R702.4.2, Table R906.2

C1283—11

Practice for Installing Clay Flue Lining

R1003.9.1, R1003.12

C1288—99 (2010)

Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets

Table R503.2.1.1(1), Table R503.2.1.1(2), Table 602.3(2), Table R702.4.2

C1289—13e1

Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board

R316.8, R703.11.2.1, Table R703.15.1, Table R703.15.2, Table R703.16.1, Table R703.16.2, Table R906.2

C1325—08b

Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Interior Substrate Sheets Backer Units

Table R702.4.2

C1328/C1328M—12

Specification for Plastic (Stucco) Cement

R702.2.2

C1363—11

The Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus

N1101.10.4.1

C1364—10B

Standard Specification for Architectural Cast Stone

R606.2.5

C1386—07

Standard Specification for Precast Autoclaved Aerated Concrete (AAC) Wall Construction Units

R606.2.3

C1396/C1396M—2013

Specification for Gypsum Board

Table R602.3(1), R702.2.1, R702.2.2, R702.3.1, R702.3.7

C1405—12

Standard Specification for Glazed Brick (Single Fired, Brick Units)

R606.2.2

C1440—08

Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems

P3003.13

C1460—08

Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground

P3003.18

C1461—08

Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use

P3003.13

C1492—03 (2009)

Specification for Concrete Roof Tile

R905.3.5

C1513—2013

Standard Specification for Steel Tapping Screws for Cold-formed Steel Framing Connections

R505.2.5, R603.2.5, R702.3.8.1, Table R703.3(2), R804.2.5 Table R703.16.1, Table R703.16.2

C1540—11

Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings

P3003.4.3

C1634—11

Standard Specification for Concrete Facing Brick

R606.2.1

C1658/C1658M—12

Standard Specification for Glass Mat Gypsum Panels

R702.3.1

C1668—12

Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating, Ventilation, and Air Conditioning (HVAC) Systems

M1601.3

D41—05

Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing

Table R905.9.2, Table R905.11.2

D43—00 (2006)

Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing

Table R905.9.2

D226/D226M—09

Specification for Asphalt-saturated (Organic Felt) Used in Roofing and Waterproofing

R703.2, R905.1.1, Table R905.1.1(1), R905.8.4, Table R905.9.2

D227/D 227M—03 (2011)e1

Specification for Coal Tar Saturated (Organic Felt) Used in Roofing and Waterproofing

Table R905.9.2

D312—00 (2006)

Specification for Asphalt Used in Roofing

Table R905.9.2

D422—63 (2007)

Test Method for Particle-size Analysis of Soils

R403.1.8.1

D449—03 (2008)

Specification for Asphalt Used in Dampproofing and Waterproofing

R406.2

D450—07

Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing

Table R905.9.2

D1227—95 (2007)

Specification for Emulsified Asphalt Used as a Protective Coating for Roofing

Table R905.9.2, Table R905.11.2, R905.15.2

D1248—12

Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable

M1601.1.2

D1527—99 (2005)

Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe, Schedules 40 and 80

Table P2906.4

D1621—10

Standard Test Method for Compressive Properties of Rigid Cellular Plastics

Table R610.3.1

D1622—08

Standard Test Method for Apparent Density of Rigid Cellular Plastics

Table R610.3.1

D1623—09

Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

Table R610.3.1

D1693—2013

Test Method for Environmental Stress-cracking of Ethylene Plastics

Table M2101.1

D1784—11

Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds

M1601.1.2

D1785—12

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120

Table P2906.4, Table AG101.1

D1863/D1863M—05 (2011)e1

Specification for Mineral Aggregate Used in Built-up Roofs

Table R905.9.2

D1869—95 (2010)

Specification for Rubber Rings for Asbestos-cement Pipe

P2906.17, P3003.13

D1970/D1970M—2013

Specification for Self-adhering Polymer Modified Bitumen Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection

R905.1.1, R905.2.8.2, R905.16.4

D2104—03

Specification for Polyethylene (PE) Plastic Pipe, Schedule 40

Table P2905.4

D2126—09

Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging

Table R610.3.1

D2178—04

Specification for Asphalt Glass Felt Used in Roofing and Waterproofing

Table R905.9.2

D2235—04 (2011)

Specification for Solvent Cement for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe and Fittings

P2906.9.1.1, P3003.3.2

D2239—12A

Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter

Table P2906.4, Table AG101.1

D2241—09

Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series)

Table P2905.4, Table AG101.1

D2282—99 (2005)

Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe (SDR-PR)

Table P2905.4

D2412—11

Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-plate Loading

M1601.1.2

D2447—03

Specification for Polyethylene (PE) Plastic Pipe Schedules 40 and 80, Based on Outside Diameter

Table M2101.1

D2464—06

Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

Table P2906.6

D2466—06

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40

Table P2906.6

D2467—06

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

Table P2906.6

D2468—96a

Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe Fittings, Schedule 40

Table P2906.6

D2513—2013e1

Specification for Thermoplastic Gas Pressure Pipe, Tubing and Fittings

Table M2101.1, G2414.6, G2414.6.1, G2414.11, G2415.17.2

D2559—12A

Standard Specification for Adhesives for Bonded Structural Wood Products for Use Under Exterior (West Use) Exposure Conditions

R610.3.3

D2564—12

Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems

P2906.9.1.4, P3003.8.2, P3003.9.2

D2609—02 (2008)

Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe

Table P2906.6

D2626/D2626M—04 (2012)e1

Specification for Asphalt-saturated and Coated Organic Felt Base Sheet Used in Roofing

R905.3.3, Table R905.9.2

D2657—07

Standard Practice for Heat Fusion-joining of Polyolefin Pipe Fittings

M2105.11.1, P2906.3.1, P3003.12.1

D2661—11

Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, P3003.3.2

D2665—12

Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste and Vent Pipe and Fittings

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, Table AG101.1

D2672—96a (2009)

Specification for Joints for IPS PVC Pipe Using Solvent Cement

Table P2906.4

D2683—2010e1

Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing

Table M2105.5, M2105.11.1, P3010.5

D2729—11

Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings

P3009.11, Table P3302.1, Table AG101.1

D2737—2012A

Specification for Polyethylene (PE) Plastic Tubing

Table P2906.4, Table AG101.1

D2751—05

Specification for Acrylonitrile-butadiene-styrene (ABS) Sewer Pipe and Fittings

Table P3002.2, Table P3002.3

D2822/D2822M—05 (2011)e1

Specification for Asphalt Roof Cement, Asbestos Containing

Table R905.9.2

D2823/D2823M—05 (2011)e1

Specification for Asphalt Roof Coatings, Asbestos Containing

Table R905.9.2

D2824—06 (2012)e1

Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered, Asbestos Fibered and Fibered without Asbestos

Table R905.9.2, Table R905.11.2

D2846/D2846M—09BE1

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-water Distribution Systems

Table M2101.1, Table P2906.4, Table P2906.5, Table P2906.6, P2906.9.1.2, P2906.9.1.3, Table AG101.1

D2855—96 (2010)

Standard Practice for Making Solvent-cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings

P3003.9.2

D2898—10

Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing

R802.1.5.4, R802.1.5.8

D2949—10

Specification for 3.25-in. Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste and Vent Pipe and Fittings

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, Table AG101.1

D3019—08

Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered

Table R905.9.2, Table R905.11.2

D3034—08

Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings

Table P3002.2, Table P3002.3, Table P3202.1, Table AG101.1

D3035—2012e1

Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter

Table M2105.4, Table AG101.1

D3161/D3161M—2013

Test Method for Wind Resistance of Asphalt Shingles (Fan Induced Method)

R905.2.4.1, Table R905.2.4.1, R905.16.7

D3201—2013

Test Method for Hygroscopic Properties of Fire-retardant Wood and Wood-base Products

R802.1.5.9

D3212—07

Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals

P3003.3.1, P3003.9.1, P3003.12.2

D3261—12

Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing

Table M2105.5, M2105.11.1

D3309—96a (2002)

Specification for Polybutylene (PB) Plastic Hot- and Cold-water Distribution System

Table M2101.1

D3311—11

Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns

P3002.3

D3350—2012e1

Specification for Polyethylene Plastic Pipe and Fitting Materials

Table M2101.1

D3462/D3462M—10A

Specification for Asphalt Shingles Made From Glass Felt and Surfaced with Mineral Granules

R905.2.4

D3468—99 (2006)e01

Specification for Liquid-applied Neoprene and Chlorosulfanated Polyethylene Used in Roofing and Waterproofing

R905.15.2

D3679—11

Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding

R703.11

D3737—2012

Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam)

R502.1.3, R602.1.3, R802.1.2

D3747—79 (2007)

Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation

Table R905.9.2, Table R905.11.2

D3909/D3909M—97b (2012)e1

Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules

R905.2.8.2, R905.5.4, Table R905.9.2, R337.5.2, R337.5.3

D4022/D4022M—2007 (2012)e1

Specification for Coal Tar Roof Cement, Asbestos Containing

Table R905.9.2

D4068—09

Specification for Chlorinated Polyethylene (CPE) Sheeting for Concealed Water Containment Membrane

P2709.2, P2709.2.2

D4318—10

Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils

R403.1.8.1

D4434/D4434M—12

Specification for Poly (Vinyl Chloride) Sheet Roofing

R905.13.2

D4479/D4479M—07 (2012)e1

Specification for Asphalt Roof Coatings-asbestos-free

Table R905.9.2

D4551—12

Specification for Poly (Vinyl) Chloride (PVC) Plastic Flexible Concealed Water-containment Membrane

P2709.2, P2709.2.1

D4586/D4586M—07 (2012)e1

Specification for Asphalt Roof Cement-asbestos-free

Table R905.9.2

D4601/D4601M—04 (2012)e1

Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing

Table R905.9.2

D4637/D4637M—2013

Specification for EPDM Sheet Used in Single-ply Roof Membrane

R905.12.2

D4829—11

Test Method for Expansion Index of Soils

R403.1.8.1

D4869/D4869M—05 (2011)e01

Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing

R905.1.1, Table R905.1.1(1), R905.16.3, R905.16.4.2

D4897/D4897M—01 (2009)

Specification for Asphalt Coated Glass-fiber Venting Base Sheet Used in Roofing

Table R905.9.2

D4990—97a (2005)e01

Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing

Table R905.9.2

D5019—07a

Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane

R905.12.2

D5055—2013

Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists

R502.1.2

D5456—2013

Standard Specification for Evaluation of Structural Composite Lumber Products

R502.1.5, R602.1.5, R802.1.7

D5516—09

Test Method for Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures

R802.1.5.7

D5643/D5643M—06 (2012)e1

Specification for Coal Tar Roof Cement Asbestos-free

Table R905.9.2

D5664—10

Test Methods For Evaluating the Effects of Fire-retardant Treatments and Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber

R802.1.5.7

D5665—99a (2006)

Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing

Table R905.9.2

D5726—98 (2005)

Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing

Table R905.9.2

D6083—05e01

Specification for Liquid-applied Acrylic Coating Used in Roofing

Table R905.9.2, Table R905.11.2, Table R905.14.3, R905.15.2

D6162—2000a (2008)

Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements

Table R905.11.2

D6163—00 (2008)

Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements

Table R905.11.2

D6164/D6164M—11

Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Polyester Reinforcements

Table R905.11.2

D6222/D6222M—11

Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements

Table R905.11.2

D6223/D6223M—02 (2011)e1

Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcement

Table R905.11.2

D6298—05e1

Specification for Fiberglass-reinforced Styrene Butadiene Styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface

Table R905.11.2

D6305—08

Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing

R802.1.5.6

D6380—03 (2009)

Standard Specification for Asphalt Roll Roofing (Organic Felt)

Table R905.1.1(1), R905.2.8.2, R905.5.4

D6694—08

Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing Systems

Table R905.14.3, R905.15.2

D6754/D6745M—10

Standard Specification for Ketone-ethylene-ester-based Sheet Roofing

R905.13.2

D6757—2013

Standard Specification for Inorganic Underlayment for Use with Steep Slope Roofing Products

Table R905.1.1(1), R905.1.1, R905.16.3, R905.16.4.2

D6841—08

Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber

R802.1.5.7

D6878/D6878—11a

Standard Specification for Thermoplastic-polyolefin-based Sheet Roofing

R905.13.2

D6947—07

Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System

Table R905.14.3, R905.15.2

D7032—10a

Standard Specification for Establishing Performance Ratings for Wood-plastic Composite Deck Boards and Guardrail Systems (Guards or Handrails)

R507.3, R507.3.1, 507.3.4, 507.3.4

D7158—D7158M—2011

Standard Test Method for Wind Resistance of Sealed Asphalt Shingles (Uplift Force/Uplift Resistance Method)

R905.2.4.1, Table R905.2.4.1

D7254—07

Standard Specification for Polypropylene (PP) siding

Table R703.3(1), R703.14

D7425/D7425M—11

Standard Specification for Spray Polyurethane Foam Used for Roofing Application

R905.14.2

D7672—2012

Standard Specification for Evaluating Structural Capacities of Rim Board Products and Assemblies

R502.1.7, R602.1.7, R802.1.7

D7793—13

Standard Specification for Insulated Vinyl Siding

R703.13, Table R703.3(1)

E84—2016

Standard Test Method for Surface Burning Characteristics of Building Materials

R202, R302.9.3, R302.9.4, R302.10.1, R302.10.2, R316.3, R316.5.9, R316.5.11, R337.9.3, R507.3.2, R802.1.5, M1601.3, M1601.5.2

E96/E96M—2013

Test Method for Water Vapor Transmission of Materials

R202, Table R610.3.1, M1411.6 M1601.4.6

E108—2011

Test Methods for Fire Tests of Roof Coverings

R302.2.2, R902.1

E119—2012a

Test Methods for Fire Tests of Building Construction and Materials

Table R302.1(1), Table R302.1(2), R302.2, R302.2.2, R302.3, R302.4.1, R302.11.1

E136—2012

Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C

R202, R302.11

E283—04

Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen

N1102.4.5

E330—02

Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference

R609.4, R609.5, R612.4, R703.1.2

E331—00 (2009)

Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference

R703.1.1

E779—10

Standard Test Method for Determining Air Leakage Rate by Fan Pressurization

N1102.4.1.2

E814—2013

Test Method for Fire Tests of Through-penetration Firestops

R302.4.1.2

E970—2010

Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source

R302.10.5

E1509—12

Standard Specification for Room Heaters, Pellet Fuel-burning Type

M1410.1

E1602—03 (2010)e1

Guide for Construction of Solid Fuel Burning Masonry Heaters

R1002.2

E1827—11

Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door

N1102.4.1.2

E1886—05

Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials

R301.2.1.2, R609.6.1

E1996—2012a

Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes

R301.2.1.2, R301.2.1.2.1, R609.6.1

E2178—2013

Standard Test Method for Air Permeance of Building Materials

R202

E2231—09

Standard Practice for Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surface Burning Characteristics

M1601.3

E2273—03 (2011)

Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies

R703.9.2

E2568—09e1

Standard Specification for PB Exterior Insulation and Finish Systems

R703.9.1, R703.9.2

E2570—07

Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings Used Under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage

R703.9.2

E2632/E2632M—2013e1

Standard Test Method for Evaluating the Under-Deck Fire Test Response of Deck Materials

R337.9.3, R337.9.4, R337.9.4.1, R337.9.5

E2634—11

Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems

R404.1.3.3.6.1, R608.4.4

E2707—2015

Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure

R337.7.3, R337.7.3.1, R337.8.3

E2726/E2726M—2012a

Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands

R337.9.3, R337.9.4, R337.9.4.2

E2886/E2886M—2014

Standard Test Method for Evaluating the Ability of Exterior Vents to Resist the Entry of Embers and Direct Flame Impingent

*ASTM E2886, Amended Sections as follows:
Revise Sections 10.1.8.3, 10.1.8.4, and 10.1.8.5 as follows:
10.1.8.3 Report the temperatures of the unexposed temperatures on the unexposed side of the vent during the entire optional Insulation Test of the Flame Intrusion.
10.1.8.4 The maximum temperature reached during the test by any one of the unexposed surface thermocouples during the entire optional Insulation Test of the Flame Intrusion Test.
10.1.8.5 The maximum average temperature reached during the test by all of the unexposed surface thermocouples during the entire optional Insulation Test of the Flame Intrusion Test.

R337.6.2, R337.6.3

E2957—2015

Standard Test Method for Resistance to Wildfire Penetration of Eaves, Soffits and Other Projections


*ASTM E2957, Amended Sections as follows: Add new Section 12.5 as follows:
12.5 Conditions of Acceptance: Should one of the three replicates fail to meet the Conditions of Acceptance, three additional tests may be run. All of the additional tests must meet the Conditions of Acceptance. 1. Absence of flame penetration of the eaves or horizontal projection assembly at any time.
2. Absence of structural failure of the eaves or horizontal projection subassembly at any time.
3. Absence of sustained combustion of any kind at the conclusion of the 40-minute test.

R337.7.5, R337.7.6, R337.7.8, R337.7.10

F405—05

Specification for Corrugated Polyethylene (PE) Pipe and Fittings

Table P3009.11, Table P3302.1, Table AG101.1

F409—12

Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings

Table P2701.1, P2702.2, P2702.3

F437—09

Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table P2906.6

F438—09

Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40

Table P2906.6

F439—12

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table P2906.6

F441/F441M—13

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80

Table P2906.4, Table P2906.5, Table AG101.1

F442/F442M—13

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)

Table P2906.4, Table P2906.5, Table AG101.1

F477—10

Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe

P2906.17, P3003.13

F493—10

Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings

P2906.9.1.2, P2906.9.1.3

F628—08

Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic Drain, Waste and Vent Pipe with a Cellular Core

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, P3003.3.2, Table AG101.1

F656—10

Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings

P2906.9.1.4, P3003.9.2

F714—13

Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter

Table P3002.2, P3010.4

F876—13

Specification for Cross-linked Polyethylene (PEX) Tubing

Table M2101.1, Table P2906.4, Table P2906.5, Table AG101.1

F877—11A

Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and Cold-water Distribution Systems

Table M2101.1, Table P2906.4, Table P2906.5, Table P2906.6

F891—10

Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3302.1, Table AG101.1

F1055—13

Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene Pipe and Tubing

Table M2105.5, M2105.11.2

F1281—11

Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Pressure Pipe

Table M2101.1, Table P2906.4, Table P2906.5, Table P2906.6, P2506.11.1, Table AG101.1

F1282—10

Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe

Table M2101.1, Table P2906.4, Table P2906.5, Table P2906.6, P2906.11.1, Table AG101.1

F1412—09

Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage

Table P3002.1(2), Table P3002.2, Table P3002.3, P3003.11.1

F1488—09e1

Specification for Coextruded Composite Pipe

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3009.11

F1554—07a

Specification for Anchor Bolts, Steel, 36, 55 and 105-ksi Yield Strength

R608.5.2.2

F1667—11A e1

Specification for Driven Fasteners, Nails, Spikes and Staples

R317.3, R703.3.2, R703.6.3, Table R703.15.1, Table R703.15.2, R905.2.5

F1807—13

Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing

Table M2101.1, Table P2906.6

F1866—07

Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings

Table P3002.3

F1924—12

Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing

M2105.11.1

F1960—12

Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing

Table M2101.1, Table P2906.6

F1970—12

Standard Specification for Special Engineered Fittings, Appurtenances or Valves for Use in Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Systems

M2105.5, Table 2903.9.4

F1973—08

Standard Specification for Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA 11) Fuel Gas Distribution Systems

G2415.15.2

F1974—09

Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe

P2506.11.1, Table P2906.6

F1986—01 (2011)

Multilayer Pipe Type 2, Compression Joints for Hot and Cold Drinking Water Systems

Table P2906.4, Table P2906.5, Table P2906.6

F2080—12

Specification for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe

P2906.6

F2090—10

Specification for Window Fall Prevention Devices—with Emergency Escape (Egress) Release Mechanisms

R310.1.1, R312.2.1, R312.2.2, R612.2, R612.3

F2098—08

Standard Specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert Fittings

Table M2101.1, Table P2906.6

F2159—11

Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing

Table P2906.6

F2262—09

Standard Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Tubing OD Controlled SDR9

Table P2906.4, Table P2906.5

F2389—10

Standard for Pressure-rated Polypropylene (PP) Piping Systems

Table M2105.12.1, Table P2906.4, Table P2906.5, Table P2906.6, P2906.10.1, Table AG101.1

F2434—09

Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Tubing

Table P2906.6

F2623—08

Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDRG Tubing

Table M2101.1, Table AG101.1

F2735—09

Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing

Table M2101.1, Table P2906.6

F2769—10

Polyethylene or Raised Temperature (PE-RT) Plastic Hot and Cold-Water Tubing and Distribution Systems

Table M2101.1, Table P2906.4, Table P2906.5, Table P2906.6, Table AG101.1

F2806—10

Standard Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe (Metric SDR-PR)

Table M2101.1

F2855—12

Standard Specification for Chlorinated Poly (Vinyl Chloride)/Aluminum/Chlorinated Poly (Vinyl Chloride) (CPVC AL CPVC) Composite Pressure Tubing

Table P2906.4, Table P2906.5, Table AG101.1

F2969—12

Standard Specification for Acrylonitrile-butadiene-styrene (ABS) IPS Dimensioned Pressure Pipe

Table M2101.1

AWC

American Wood Council
222 Catocin Circle, Suite 201
Leesburg VA 20175
Standard
reference
number
TitleReferenced
in code
section number

AWC STJR—2015

Span Tables for Joists and Rafters

R502.3, R802.4, R802.5

AWC WFCM—2015

Wood Frame Construction Manual for One- and Two-family Dwellings

R301.1.1, R301.2.1.1, R602.10.8.2, R608.9.2, Figure R608.9(9), R608.10

ANSI AWC NDS—2015

National Design Specification (NDS) for Wood Construction—with 2015 NDS Supplement

R404.2.2, R502.2, Table R503.1, R602.3, R608.9.2, Table R703.15.1, Table R703.15.2, R802.2

ANSI AWC PWF—2015

Permanent Wood Foundation Design Specification

R317.3.2, R401.1, R404.2.3

AWPA

American Wood Protection Association
P.O. Box 361784
Birmingham AL 35236-1784
Standard
reference
number
TitleReferenced
in code
section number

C1—03

All Timber Products—Preservative Treatment by Pressure Processes

R902.2

M4—11

Standard for the Care of Preservative-treated Wood Products

R317.1.1, R318.1.2

U1—14

USE CATEGORY SYSTEM: User Specification for Treated Wood Except Section 6 Commodity Specification H

R317.1, R402.1.2, R504.3, R703.6.3, R905.7.5, Table R905.8.5, R905.8.6

AWS

American Welding Society
550 N. W. LeJeune Road
Miami FL 33126
Standard
reference
number
TitleReferenced
in code
section number

A5.8M/A5.8—2011

Specifications for Filler Metals for Brazing and Braze Welding

P3003.6.1

ANSI/AWS A5.31M/A5.31—2012

Specification for Fluxes for Brazing and Braze Welding Edition: 2nd

M2103.3, M2202.2, P2906.14, M2103.3

AWWA

American Water Works Association
6666 West Quincy Avenue
Denver CO 80235
Standard
reference
number
TitleReferenced
in code
section number

C104/A21.4—08

Cement-mortar Lining for Ductile-iron Pipe and Fittings for Water

P2906.4

C110/A21.10—12

Ductile-iron and Gray-iron Fittings

Table P2906.6,

C115/A21.15—11

Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges

Table P2906.4

C151/A21.51—09

Ductile-iron Pipe, Centrifugally Cast, for Water

Table P2906.4

C153/A21.53—11

Ductile-iron Compact Fittings for Water Service

Table P2906.6

C500—09

Standard for Metal-seated Gate Valves for Water Supply Service

Table P2903.9.4

C504—10

Standard for Rubber-seated Butterfly Valves

Table P2903.9.4

C507—11

Standard for Ball Valves, 6 In. Through 60 In

Table P2903.9.4

C510—07

Double Check Valve Backflow Prevention Assembly

Table P2902.3, P2902.3.6

C511—07

Reduced-pressure Principle Backflow Prevention Assembly

Table P2902.3, P2902.3.5, P2902.5.1

C901—08

Polyethylene (PE) Pressure Pipe and Tubing 1/2 in. (13 mm) through 3 in. (76 mm) for Water Service

P2906.4, Table AG101.1

C903—05

Polyethylene-aluminum-polyethylene & Crosslinked Polyethylene Composite Pressure Pipe,1/2 in. (12 mm) through 2 in. (50 mm), for Water Service

Table M2101

C904—06

Cross-linked Polyethylene (PEX) Pressure Pipe, 1/2 in. (12 mm) through 3 in. (76 mm) for Water Service

P2906.4, Table AG101.1

CEN

European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
Standard
reference
number
TitleReferenced
in code
section number

EN 15250-2007

Slow Heat Release Appliances Fired by Solid Fuel Requirements and Test Methods

R1002.5

CGSB

Canadian General Standards Board
Place du Portage 111, 6B1 11 Laurier Street
Gatineau Quebec Canada KIA 1G6
Standard
reference
number
TitleReferenced
in code
section number

CAN/CGSB-37.54—95

Polyvinyl Chloride Roofing and Waterproofing Membrane

R905.13.2

37-GP-52M—(1984)

Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric

R905.12.2

37-GP-56M—(1980)

Membrane, Modified Bituminous, Prefabricated and Reinforced for Roofing—with December 1985 Amendment

Table R905.11.2

CISPI

Cast Iron Soil Pipe Institute
5959 Shallowford Road, Suite 419
Chattanooga TN 37421
Standard
reference
number
TitleReferenced
in code
section number

301—04a

Standard Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, Table P3302.1

310—04

Standard Specification for Coupling for Use in Connection with Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications

P3003.4.3

CPA

Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg VA 20176
Standard
reference
number
TitleReferenced
in code
section number

ANSI A135.4—2012

Basic Hardboard

Table R602.3(2)

ANSI A135.5—2012

Prefinished Hardboard Paneling

R702.5

ANSI A135.6—2012

Engineered Wood Siding

R703.5

ANSI A135.7—2012

Engineered Wood Trim

R703.5

A208.1—2009

Particleboard

R503.3.1, R602.1.9, R605.1

CPSC

Consumer Product Safety Commission
4330 East West Highway
Bethesda MD 20814-4408
Standard
reference
number
TitleReferenced
in code
section number

16 CFR, Part 1201—(2002)

Safety Standard for Architectural Glazing

R308.1.1, R308.3.1, Table R308.3.1(1)

16 CFR, Part 1209—(2002)

Interim Safety Standard for Cellulose Insulation

R302.10.3

16 CFR, Part 1404—(2002)

Cellulose Insulation

R302.10.3

CSA

CSA Group
8501 East Pleasant Valley Road
Cleveland OH 44131-5516
Standard
reference
number
TitleReferenced
in code
section number

AAMA/WDMA/CSA 101/I.S.2/A440—11

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R308.6.9, R609.3, N1102.4.3

ANSI/CSA America FCI—2012

Stationary Fuel Cell Power Systems

M1903.1

ASME A112.3.4—2013/CSA B45.9—13

Macerating Toilet Systems and Related Components

Table P2701.1, P3007.5

ASME A112.18.1—2012/CSA B125.1—2012

Plumbing Supply Fittings

Table P2701.1, P2708.4, P2708.5, P2722.1, P2722.2, P2722.3, P2902.2, Table P2903.9.4

ASME A112.18.2—2011/CSA B125.2—2011

Plumbing Waste Fittings

Table P2701.1, P2702.2

A112.18.6/CSA B125.6—2009

Flexible Water Connectors

P2906.7

ASME A112.19.1—2013/CSA B45.2—13

Enameled Cast-iron and Enameled Steel Plumbing Fixtures

Table 2701.1, P2711.1

ASME A112.19.2—2013/CSA B45.1—13

Ceramic Plumbing Fixtures

Table P2701.1, P2705.1, P2711.1, P2712.1, P2712.2, P2712.9

ASME A112.19.3—2008/CSA B45.4—08 (R2013)

Stainless Steel Plumbing Fixtures

Table P2701.1, P2705.1, P2711.1, P2712.1

ASSE 1016/ASME 112.1016/CSA B125.16—2011

Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations

Table P2701.1, P2708.4, P2722.2

A112.19.5—2011/CSA B45.15—2011

Flush Valves and Spuds for Water-closets, Urinals and Tanks

Table P2701.1

A112.19.7—2012/CSA B45.10—2012

Hydromassage Bathtub Systems

Table P2701.1

ASME A17.1/CSA B44—2013

Safety Code for Elevators and Escalators

R321.1

CSA 8—93

Requirements for Gas Fired Log Lighters for Wood Burning Fireplaces—with Revisions through January 1999

G2433.1

A257.1M—2009

Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings

Table P3002.2

A257.2M—2009

Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings

Table P3002.2, P3003.13

A257.3M—2009

Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and Fittings Using Rubber Gaskets

P3003.5, P3003.18

B64.1.1—11

Vacuum Breakers, Atmospheric Type (AVB)

Table P2902.3, P2902.3.2

B64.1.2—11

Pressure Vacuum Breakers (PVB)

Table P2902.3, P2902.3.4

B64.1.3—11

Spill Resistant Pressure Vacuum Breakers (SRPVB)

P2902.3.2

B64.2—11

Vacuum Breakers, Hose Connection Type (HCVP)

Table P2902.3, P2902.3.2

B64.2.1—11

Hose Connection Vacuum Breakers (HCVB) with Manual Draining Feature

Table P2902.3, P2902.3.2

B64.2.1.1—11

Hose Connection Dual Check Vacuum Breakers (HCDVB)

Table P2902.3, P2902.3.2

B64.2.2—11

Vacuum Breakers, Hose Connection Type (HCVP) with Automatic Draining Feature

Table P2902.3, P2902.3.2

B64.3—11

Dual Check Backflow Preventers with Atmospheric Port (DCAP)

, Table P2902.3, P2902.5.1

B64.4—11

Backflow Preventers, Reduced Pressure Principle Type (RP)

Table P2902.3, P2902.3.5, P2903.5.1

B64.4.1—11

Reduced Pressure Principle for Fire Sprinklers (RPF)

Table P2902.3, P2902.3.5

B64.5—11

Double Check Backflow Preventers (DCVA)

Table P2902.3, P2902.3.6

B64.5.1—11

Double Check Valve Backflow Preventers, Type for Fire Systems (DCVAF)

Table P2902.3, P2902.3.6

B64.6—11

Dual Check Valve Backflow Preventers (DuC)

Table P2902.3, P2902.3.7

B64.7—11

Laboratory Faucet Vacuum Breakers (LFVB)

Table P2902.3, P2902.3.2

B125.3—12

Plumbing Fittings

Table 2701.1, P2713.3, P2721.2, Table P2902.3, P2902.4.1, Table P2903.9.4

B137.1—13

Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services

Table P2906.4, Table P2906.6

B137.2—13

Polyvinylchloride PVC Injection-moulded Gasketed Fittings for Pressure Applications

Table P2906.6

B137.3—13

Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications

Table P2906.4, Table 2906.6, P3003.9.2, Table AG101.1

B137.5—13

Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications

Table P2906.4, Table P2906.5, Table P2906.6, Table AG101.1

B137.6—13

Chlorinated polyvinylchloride CPVC Pipe, Tubing and Fittings for Hot- and Cold-water Distribution Systems

Table P2906.4, Table P2906.5, Table 2906.6, Table AG101.1

B137.9—13

Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe Systems

Table M2101.1, P2506.11.1, Table P2906.4

B137.10—13

Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PE-AL-PE) Composite Pressure Pipe Systems

Table M2101.1, Table P2906.4, Table P2906.5, Table P2906.6, P2906.11.1

B137.11—13

Polypropylene (PP-R) Pipe and Fittings for Pressure Applications

Table P2906.4, Table 2906.5, Table P2906.6, Table AG101.1

B181.1—11

Acrylonitrile-butadiene-styrene (ABS) Drain, Waste and Vent Pipe and Pipe Fittings

Table P3002.1(1), Table P3002.1(2), Table P3002.3, P3003.3.2, P3003.8.2

B181.2—11

Polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC) Drain, Waste and Vent Pipe and Pipe Fittings

Table P3002.1(1), Table P3002.1(2), P3003.9.2, P3003.14.2, P3008.2, Table P3302.1

B181.3—11

Polyolefin and polyvinylidene (PVDF) Laboratory Drainage Systems

Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, P3003.11.1

B182.2—11

PSM Type polyvinylchloride (PVC) Sewer Pipe and Fittings

Table P3002.2, Table P3002.3, Table P3302.1

B182.4—11

Profile polyvinylchloride (PVC) Sewer Pipe & Fittings

Table P3002.2, Table P3002.3, Table P3302.1

B182.6—11

Profile Polyethylene (PE) Sewer Pipe and Fittings for leak-proof Sewer Applications

Table P3302.1

B182.8—11

Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and Fittings

Table P3302.1

B356—10

Water Pressure Reducing Valves for Domestic Water Supply Systems

P2903.3.1

B483.1—14

Drinking Water Treatment Systems

P2909.1, P2909.2

B602—10

Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe

P3003.3.1, P3003.4.3, P3003.5, P3003.9.1, P3003.10.1, P3003.12.2, P3003.13

CSA B45.5—11/IAPMO Z124—11

Plastic Plumbing Fixtures

Table P2701.1, P2711.1, P2711.2, P2712.1

CSA C448 Series-02-CAN/CSA—2002

Design and Installation of Earth Energy Systems—First Edition; Update 2: October 2009; Consolidated Reprint 10/2009

Table M2105.4, Table M2105.5

O325—07

Construction Sheathing

R503.2.1, R602.1.8, R604.1, R803.2.1

O437-Series—93

Standards on OSB and Waferboard (Reaffirmed 2006)

R503.2.1, R602.1.8, R604.1, R803.2.1

UL/CSA/ANCE 60335-2-40—2012

Standard for Household and Similar Electrical Appliances, Part 2: Particular Requirements for Motor-compressors

M1403.1, M1412.1, M1413.1 P2902.3.5, P2902.5.1

CSSB

Cedar Shake & Shingle Bureau
P. O. Box 1178
Sumas WA 98295-1178
Standard
reference
number
TitleReferenced
in code
section number

CSSB—97

Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau

R702.6, R703.5, Table R905.7.4, Table R905.8.5

DASMA

Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland OH 44115-2851
Standard
reference
number
TitleReferenced
in code
section number

108—12

Standard Method for Testing Garage Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference

R609.14

115—12

Standard Method for Testing Garage Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure

R301.2.1.2

DOC

United States Department of Commerce
1401 Constitution Avenue, NW
Washington DC 20230
Standard
reference
number
TitleReferenced
in code
section number

PS 2—10

Performance Standard for Wood-based Structural-use Panels

R404.2.1, Table R404.2.3, R503.2.1, R602.1.8, R604.1, R610.3.2, Table 610.3.2, R803.2.1

PS 20—05

American Softwood Lumber Standard

R404.2.1, R502.1.1, R602.1.1, R802.1.1

DOTn

Department of Transportation
1200 New Jersey Avenue SE
East Building, 2nd floor
Washington DC 20590
Standard
reference
number
TitleReferenced
in code
section number

49 CFR, Parts 192.281(e) & 192.283 (b) (2009)

Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards

G2414.6.1

FEMA

Federal Emergency Management Agency
500 C Street, SW
Washington DC 20472
Standard
reference
number
TitleReferenced
in code
section number

FEMA TB-2—08

Flood Damage-resistant Materials Requirements

R322.1.8

FEMA TB-11—01

Crawlspace Construction for Buildings Located in Special Flood Hazard Area

R408.7

FM

Factory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P. O. Box 7500
Johnson RI 02919
Standard
reference
number
TitleReferenced
in code
section number

4450—(1989)

Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 1992

R906.1

4880—(2010)

American National Standard for Evaluating Insulated Wall or Wall and Roof/Ceiling Assemblies, Plastic Interior Finish Materials, Plastic Exterior Building Panels, Wall/Ceiling Coating Systems, Interior and Exterior Finish Systems

R316.6

GA

Gypsum Association
6525 Belcrest Road, Suite 480
Hyattsville MD 20782
Standard
reference
number
TitleReferenced
in code
section number

GA-253—12

Application of Gypsum Sheathing

Table R602.3(1)

HPVA

Hardwood Plywood & Veneer Association
1825 Michael Faraday Drive
Reston Virginia 20190-5350
Standard
reference
number
TitleReferenced
in code
section number

ANSI/HP-1—2013

Standard for Hardwood and Decorative Plywood

R702.5

IAPMO

IAPMO
4755 E. Philadelphia Street
Ontario CA 91761-USA
Standard
reference
number
TitleReferenced
in code
section number

CSA B45.5—11/IAPMO Z124—11

Plastic Plumbing Fixtures

Table P2701.1, P2711.1, P2711.2, P2712.1

ICC

International Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington DC 20001
Standard
reference
number
TitleReferenced
in code
section number

ICC/ANSI A117.1—09

Accessible and Usable Buildings and Facilities

R321.3

ICC—ES EG107

Evaluation guideline for determination of Volatile Organic Compound (voc) content

R902

ICC 400—12

Standard on the Design and Construction of Log Structures

R301.1.1

ICC 500—14

ICC/NSSA Standard on the Design and Construction of Storm Shelters

R323.1

ICC 600—14

Standard for Residential Construction in High-wind Regions

R301.2.1.1

IFC—15

International Fire Code®

R102.7, M2201.7, G2402.3, G2412.2, G2423.1

IFGC—15

International Fuel Gas Code®

G2401.1, G2423.1

IMC—15

International Mechanical Code®

N1103.2.2, N1103.5, G2402.3

IPC—15

International Plumbing Code®

G2402.3

IPMC—15

International Property Maintenance Code®

R102.7

IPSDC—15

International Private Sewage Disposal Code®

ISPSC—15

International Swimming Pool and Spa Code

R326.1

ISO

International Organization for Standardization
1, ch. de la Voie - Creuse
Case postale 56
CH-1211 Geneva 20
Switzerland
Standard
reference
number
TitleReferenced
in code
section number

8336—2009

Fibre-cement Flat Sheets-product Specification and Test Methods

Table R503.2.1.1(1), Table R503.2.1.1(2), Table R602.3(2), Table R702.4.2, R703.10.1, R703.10.2

15874—2002

Polypropylene Plastic Piping Systems for Hot and Cold Water Installations

Table M2101.1

MSS

Manufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, Northeast
Vienna VA 22180
Standard
reference
number
TitleReferenced
in code
section number

SP-42—09

Corrosion Resistant Gate, Globe, Angle and Check Valves with Flanged and Butt Weld Ends (Glasses 150, 300 & 600)

Table P2903.9.4

SP-58—09

Pipe Hangers and Supports—Materials, Design, Manufacture, Selection, Application and Installation

G2418.2

SP-67—11

Butterfly Valves

Table P2903.9.4

SP-70—11

Gray Iron Gate Valves, Flanged and Threaded Ends

Table P2903.9.4

SP-71—11

Gray Iron Swing Check Valves, Flanged and Threaded Ends

Table P2903.9.4

SP-72—10

Ball Valves with Flanged or Butt-Welding Ends for General Service

P2903.9.4

SP-78—11

Cast Iron Plug Valves, Flanged and Threaded Ends

Table P2903.9.4

SP-80—08

Bronze Gate, Globe, Angle and Check Valves

Table P2903.9.4

SP-110—10

Ball Valves, Threaded, Socket Welded, Solder Joint, Grooved and Flared Ends

Table P2903.9.4

NAIMA

North American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria VA 22314
Standard
reference
number
TitleReferenced
in code
section number

AH 116—09

Fibrous Glass Duct Construction Standards, Fifth Edition

M1601.1.1

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02269
Standard
reference
number
TitleReferenced
in code
section number

13—16

Installation of Sprinkler Systemsas amended*

R302.3

See CCR, Title 24 Part 2 California Building Code, Chapter 35 or CCR, Title 24, Part 9 California Fire Code, Chapter 80 for amendments to NFPA 13.

13D—16

Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homesas amended*

R313.1.1, R313.2.1, R313.3.1, R313.3.2, R313.3.2.3.1, R313.3.2.4.2, R313.3.6.1

*NFPA 13D, Amended Sections as follows:
Revise Section 6.2.2 to read as follows:
6.2.2 Where a well, pump, tank or combination thereof is the source of supply for a fire sprinkler system, the configuration for the system shall be one of the following:
(1) The water supply shall serve both domestic and fire sprinkler systems,
(a) A test connection shall be provided downstream of the pump that creates a flow of water equal to the smallest sprinkler on the system. The connection shall return water to the tank.
(b) Any disconnecting means for the pump shall be approved.
(c) A method for refilling the tank shall be piped to the tank.
(d) A method of seeing the water level in the tank shall be provided without having to open the tank.
(e) The pump shall not be permitted to sit directly on the floor.
(2) A stand-alone tank is permitted if the following conditions are met:
(a) The pump shall be connected to a 220-volt circuit breaker shared with a common household appliance (e.g., range, oven, dryer),
(b) The pump shall be a stainless steel 240-volt pump,
(c) A valve shall be provided to exercise the pump. The discharge of the exercise valve shall drain to the tank, and
(d) A sign shall be provided stating "Valve must be opened monthly for 5 minutes."
(e) A means for automatically refilling the tank level, so that the tank capacity will meet the required water supply duration in minutes, shall be provided.
(f) A test connection shall be provided downstream of the pump that creates a flow of water equal to the smallest sprinkler on the system. The connection may return water to the tank.
(g) Any disconnecting means for the pump shall be approved.
(h) A method for refilling the tank shall be piped to the tank.
(i) A method of seeing the water level in the tank shall be provided without having to open the tank.
(j) The pump shall not be permitted to sit directly on the floor.

Add new Section 6.2.2.1 to read as follows:
6.2.2.1 Where a fire sprinkler system is supplied by a stored water source with an automatically operated means of pressurizing the system other than an electric pump, the water supply may serve the sprinkler system only.
Add new Section 6.2.4 to read as follows:
6.2.4 Where a water supply serves both domestic and fire sprinkler systems, 5 gpm (19 L/min) shall be added to the sprinkler system demand at the point where the systems are connected, to determine the size of common piping and the size of the total water supply requirements where no provision is made to prevent flow into the domestic water system upon operation of a sprinkler. For multipurpose piping systems, the 5 gpm (19 L/min) demand shall be added at the domestic connection nearest the design area. This demand may be split between two domestic connections at 2.5 gpm (10 L/min) each.
Revise Section 8.3.4 to read as follows:
8.3.4* Sprinklers shall not be required in detached garages, open attached porches, carports with no habitable space above, and similar structures.
Revise Section 8.3.4 to read as follows:
8.3.4* Sprinklers shall not be required in detached garages, open attached porches, carports with no habitable space above, and similar structures.
Add new Section 8.3.10 and 8.3.10.1 as follows:
8.3.10 Solar photovoltaic panel structures
8.3.10.1 Sprinklers shall be permitted to be omitted from the following structures: (1) Solar photovoltaic panel structures with no use underneath. Signs may be provided, as determined by the enforcing agency prohibiting any use underneath including storage. (2) Solar photovoltaic (PV) panels supported by framing that have sufficient uniformly distributed and unobstructed openings throughout the top of the array (horizontal plane) to allow heat and gases to escape, as determined by the enforcing agency.

13R—16

See CCR, Title 24 Part 2 California Building Code, Chapter 35 or CCR, Title 24, Part 9 California Fire Code, Chapter 80 for amendments to NFPA 13.

31—11

Standard for the Installation of Oil-burning Equipment

M1701.1, M1801.3.1, M1805.3

58—14

Liquefied Petroleum Gas Code

G2412.2, G2414.6.2

70—14

National Electrical Code

E3401.1, E3401.2, E4301.1, Table E4303.2, E4304.3, E4304.4, R324.3

72—16

National Fire Alarm and Signaling Code as amended*

R314.1, R314.2, R314.3.4, R325.5.2.1, R235.5.2.4

*NFPA 72, Amended Sections as follows:
Revise Section 10.3.1 to read as follows:
10.3.1 Equipment constructed and installed in conformity with this code shall be listed for the purpose for which it is used. Fire alarm systems and components shall be California State Fire Marshal approved and listed in accordance with California Code of Regulations, Title 19, Division 1.
Revise Section 10.3.3 to read as follows:
10.3.3 All devices and appliances that receive their power from the initiating device circuit or signaling line circuit of a control unit shall be California State Fire Marshal listed for use with the control unit.
Revise Section 10.7.1 to read as follows:
10.7.1 Where approved by the authority having jurisdiction, ECS priority signals when evaluated by stakeholders through risk analysis in accordance with 24.3.11 shall be permitted to take precedence over all other signals.
Revise Section 12.3.8.1 to read as follows:
12.3.8.1 The outgoing and return (redundant) circuit conductors shall be permitted in the same cable assembly (i.e., multiconductor cable), enclosure, or raceway only under the following conditions:
(1) For a distance not to exceed 10 ft (3.0 m) where the outgoing and return conductors enter or exit the initiating device, notification appliance, or control unit enclosures
(2) Single drops installed in the raceway to individual devices or appliances
(3) *In a single room not exceeding 1000 ft2 (93 m2) in area, a drop installed in the raceway to multiple devices or appliances that does not include any emergency control function devices
(4) Where the vertically run conductors are contained in a 2-hour rated cable assembly, or enclosed (installed) in a 2-hour rated enclosure or a listed circuit integrity (C.I.) cable, which meets or exceeds a 2-hour fire resistive rating.
Revise Section 14.4.6.1 to read as follows:
14.4.6.1 Testing. Household fire alarm systems shall be tested in accordance with the manufacturer's published instructions according to the methods of Table 14.4.3.2.
Revise Section 17.15 to read as follows:
17.15 Fire Extinguisher Electronic Monitoring Device. A fire extinguisher electronic monitoring device shall indicate those conditions for a specific fire extinguisher required by California Code of Regulations, Title 19, Division 1, Chapter 1, Section 574.2 (c) and California Fire Code to a fire alarm control unit.
Revise Section 21.3.6 to read as follows:
21.3.6 Smoke detectors shall not be installed in unsprinklered elevator hoistways unless they are installed to activate the elevator hoistway smoke relief equipment or where required by Chapter 30 of the California Building Code.
Revise Section 23.8.5.1.2 to read as follows:
23.8.5.1.2 Where connected to a supervising station, fire alarm systems employing automatic fire detectors or waterflow detection devices shall include a manual fire alarm box to initiate a signal to the supervising station.
Exception: Fire alarm systems dedicated to elevator recall control, and supervisory service and fire sprinkler monitoring as permitted in Section 21.3 of NFPA 72.
Revise Section 23.8.5.4.1 to read as follows:
23.8.5.4.1 Systems equipped with alarm verification features shall be permitted under the following conditions:
(1) The alarm verification feature is not initially enabled unless conditions or occupant activities that are expected to cause nuisance alarms are anticipated in the area that is protected by the smoke detectors. Enabling of the alarm verification feature shall be protected by password or limited access.
(2) A smoke detector that is continuously subjected to a smoke concentration above alarm threshold does not delay the system functions of Sections 10.7 through 10.16, 23.8.1.1, or 21.2.1 by more than 30 seconds.
(3) Actuation of an alarm-initiating device other than a smoke detector causes the system functions of Sections 10.7 through 10.16, 23.8.1.1, or 21.2.1 without additional delay.
(4) The current status of the alarm verification feature is shown on the record of completion (see Figure 7.8.2(a), item 4.3).
(5) Operation of a patient room smoke detector in I-2 and R-2.1 Occupancies shall not include an alarm verification feature.
Revise Section 29.3.1 to read as follows:
29.3.1 All devices, combinations of devices, and equipment to be installed in conformity with this chapter shall be approved and listed by the California State Fire Marshal for the purposes for which they are intended.
Revise Section 29.5.2.1.1 to read as follows:
29.5.2.1.1* Smoke and Heat Alarms. Unless exempted by applicable laws, codes, or standards, smoke or heat alarms used to provide a fire-warning function, and when two or more alarms are installed within a dwelling unit, suite of rooms, or similar area, shall be arranged so that the operation of any smoke or heat alarm causes all alarms within these locations to sound.
Note: Exception to 29.5.2.1.1 not adopted by the SFM
Add Section 29.7.2.1 to read as follows:
29.7.2.1 The alarm verification feature shall not be used for household fire warning equipment.
Add Section 29.7.6.7.1 to read as follows:
29.7.6.7.1 The alarm verification feature shall not be used for household fire warning equipment.
Revise Section 23.8.3.4 to read as follows:
29.8.3.4 Specific location requirements. The installation of smoke alarms and smoke detectors shall comply with the following requirements:
(1) Smoke alarms and smoke detectors shall not be located where ambient conditions, including humidity and temperature, are outside the limits specified by the manufacturer's published instructions.
(2) Smoke alarms and smoke detectors shall not be located within unfinished attics or garages or in other spaces where temperatures can fall below 40°F (4°C) or exceed 100°F (38°C).
(3) Where the mounting surface could become considerably warmer or cooler than the room, such as a poorly insulated ceiling below an unfinished attic or an exterior wall, smoke alarms and smoke detectors shall be mounted on an inside wall.
(4) Smoke alarms or smoke detectors shall be installed a minimum of 20 feet horizontal distance from a permanently installed cooking appliance.
Exceptions: Ionization smoke alarms with an alarm silencing switch or photoelectric smoke alarms shall be permitted to be installed 10 feet (3 m) or greater from a permanently installed cooking appliance.
Photoelectric smoke alarms shall be permitted to be installed greater than 6 feet (1.8 m) from a permanently installed cooking appliance where the kitchen or cooking area and adjacent spaces have no clear interior partitions and the 10 ft distances would prohibit the placement of a smoke alarm or smoke detector required by other sections of the code.
Smoke alarms listed for use in close proximity to a permanently installed cooking appliance.
(5)Effective January 1, 2016, smoke alarms and smoke detectors used in household fire alarm systems installed between 6 ft (1.8 m) and 20 ft (6.1 m) along a horizontal flow path from a stationary or fixed cooking appliance shall be listed for resistance to common nuisance sources from cooking.
(6) Installation near bathrooms. Smoke alarms shall be installed not less than a 3-foot (0.91 m) horizontal distance from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a smoke alarm required by other sections of the code.
(7) Smoke alarms and smoke detectors shall not be installed within a 36 in. (910 mm) horizontal path from the supply registers of a forced air heating or cooling system and shall be installed outside of the direct airflow from those registers.
(8) Smoke alarms and smoke detectors shall not be installed within a 36 in. (910 mm) horizontal path from the tip of the blade of a ceiling-suspended (paddle) fan.
(9) Where stairs lead to other occupied levels, a smoke alarm or smoke detector shall be located so that smoke rising in the stairway cannot be prevented from reaching the smoke alarm or smoke detector by an intervening door or obstruction.
(10) For stairways leading up from a basement, smoke alarms or smoke detectors shall be located on the basement ceiling near the entry to the stairs.
(11) For tray-shaped ceilings (coffered ceilings), smoke alarms and smoke detectors shall be installed on the highest portion of the ceiling or on the sloped portion of the ceiling within 12 in. (300 mm) vertically down from the highest point.
(12) Smoke alarms and detectors installed in rooms with joists or beams shall comply with the requirements of 17.7.3.2.4 of NFPA 72.
(13) Heat alarms and detectors installed in rooms with joists or beams shall comply with the requirements of 17.6.3 of NFPA 72.

85—15

Boiler and Combustion Systems Hazards Code

G2452.1

211—13

Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances

R1002.5, G2427.5.5.1

252—03

Standard Methods of Fire Tests of Door Assemblies

R337.8.3

257—13

Standard for Fire Test for Window and Glass Block Assemblies

R337.8.2.1

259—13

Test Method for Potential Heat of Building Materials

R316.5.7, R316.5.8

275—13

Standard Method of Fire Tests for the Evaluation of Thermal Barriers

R316.4

286—15

Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth

R302.9.4, R316.6

501—13

Standard on Manufactured Housing

R202

720—15

Standard for the Installation of Carbon Monoxide (CO) Detectors and Warning Equipment

R315.6.1, R315.6.2

853—15

Standard on the Installation of Stationary Fuel Cell Power Systems

M1903.1

NSF

NSF International
789 N. Dixboro
Ann Arbor MI 48105
Standard
reference
number
TitleReferenced
in code
section number

14—2011

Plastics Piping System Components and Related Materials

M1301.4, P2609.3, P2908.3

41—2011

Nonliquid Saturated Treatment Systems (Composting Toilets)

P2725.1

42—2011

Drinking Water Treatment Units—Anesthetic Effects

P2909.1, P2909.3

44—2012

Residential Cation Exchange Water Softeners

P2909.1, P2909.3

50—2012

Equipment for Swimming Pools, Hot Tubs and Other Recreational Water Facilities

P2911.8.1

53—2011A

Drinking Water Treatment Units—Health Effects

P2909.1, P2909.3

58—2012

Reverse Osmosis Drinking Water Treatment Systems

P2909.2, P2909.3

61—2012

Drinking Water System Components—Health Effects

P2609.5, P2722.1, P2903.9.4, P2906.4, P2906.5, P2906.6, P2908.3

350—2011

Onsite Residential and Commercial Water Reuse Treatment Systems

P2910.6.1

358-1—2011

Polyethylene Pipe and Fittings for Water-based Ground Source "Geothermal" Heat Pump Systems

M2105.4, M2105.5, Table AG101.1

358-2—2012

Polypropylene Pipe and Fittings for Water-based Ground Source "Geothermal" Heat Pump Systems

M2105.5

359—2012

Valves for Crosslinked Polyethylene (PEX) Water Distribution Tubing Systems

Table P2903.9.4

372—2010

Drinking Water Systems Components—Lead Content

P2906.2.1

PCA

Portland Cement Association
5420 Old Orchard Road
Skokie IL 60077
Standard
reference
number
TitleReferenced
in code
section number

100—12

Prescriptive Design of Exterior Concrete Walls for One- and Two-family Dwellings (Pub. No. EB241)

R301.2.2.2.4, R301.2.2.3.4, R404.1.3, R404.1.3.2.1, R404.1.3.2.2, R404.1.3.4, R404.1.4.2, R608.1, R608.2, R608.5.1, R608.9.2, R608.9.3

SBCA

Structural Building Components Association
6300 Enterprise Lane
Madison WI 53719
Standard
reference
number
TitleReferenced
in code
section number

BCSI—2013

Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses

502.11.2, 802.10.3

CFS-BCSI—2008

Cold-formed Steel Building Component Safety Information (CFSBCSI) Guide to Good Practice for Handling, Installing & Bracing of Cold-formed Steel Trusses

505.1.3, 804.3.6

FS100—12

Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing Used in Exterior Wall Covering Assemblies

R316.8

SFM

State of California
Department of Forestry and Fire Protection
Office of the State Fire Marshal
P.O. Box 944246
Sacramento CA 944246-2460
Standard
reference
number
TitleReferenced
in code
section number

SFM 12-3

Releasing Systems for Security Bars in Dwellings

R310

SFM 12-7A-1

Exterior Wall Siding and Sheathing

R327.5.3, R327.6.3.1, R327.6.3.2.3

SFM 12-7A-2

Exterior Window

R327.5.3, R327.6.3.2.2

SFM 12-7A-3

Horizontal Protection Underside

R327.5.3, R327.6.2.3

SFM 12-7A-4

Decking

R327.5.3, R327.6.4.1.1

SFM 12-7A-4A

Decking Alternate Method A

R327.3.7, R327.9.3.4

SFM 12-7A-5

Ignition Resistant Building Material

R327.2, R327.3.7, R327.4.2, R327.6.3.2, R327.9.3.1

(The Office of the State Fire Marshal standards referred to above are found in the California Code of Regulations, Title 24, Part 12.)

SMACNA

Sheet Metal & Air Conditioning Contractors National Assoc. Inc.
4021 Lafayette Center Road
Chantilly VA 22021
Standard
reference
number
TitleReferenced
in code
section number

SMACNA—10

Fibrous Glass Duct Construction Standards (2003)

M1601.1.1, M1601.4.1

SMACNA—15

HVAC Duct Construction Standards, Metal and Flexible (2005)

M1601.4.1

SRCC

Solar Rating & Certification Corporation
400 High Point Drive, Suite 400
Cocoa FL 32926
Standard
reference
number
TitleReferenced
in code
section number

SRCC 100—13

Standard 100 for Solar Collectors

M2301.3.1

SRCC 300—13

Standard 300 for Solar Water Heating Systems

M2301.2.3, M2301.4, M2301.2.6, M2301.2.8

SRCC 600—13

Standard 600 for Solar Concentrating Collectors

M2301.3.1

TMS

The Masonry Society
3970 Broadway, Suite 201-D
Boulder CO 80304
Standard
reference
number
TitleReferenced
in code
section number

402—2013

Building Code Requirements for Masonry Structures

R404.1.2, R606.1, R606.1.1, R606.2.3.2, R606.12.1, R606.12.2.3.1, R606.12.3.1, Table R703.4, 703.12

403—2013

Direct Design Handbook for Masonry Structures

R606.1, R606.1.1, R606.12.1, R606.12.3.1

602—2013

Specification for Masonry Structures

R404.1.2, R606.2.9, R606.2.12, R606.12.3.1, R703.12

TPI

Truss Plate Institute
218 N. Lee Street, Suite 312
Alexandria VA 22314
Standard
reference
number
TitleReferenced
in code
section number

TPI 1—2014

National Design Standard for Metal-plate-connected Wood Truss Construction

R502.11.1, R802.10.2

UBC

International Code Council, Inc.
500 New Jersey Avenue, NW 6th Floor
Washington DC 20001
Standard
reference
number
TitleReferenced
in code
section number

UBC Standard 15-2

Test Standard for determining the Fire Retardancy of Roof-covering Materials

R902

UBC Standard 15-3

Wood Shakes

R902

UBC Standard 15-4

Wood Shingles

R902

UL

UL LLC
333 Pfingsten Road
Northbrook IL 60062
Standard
reference
number
TitleReferenced
in code
section number

17—2008

Vent or Chimney Connector Dampers for Oil-fired Appliances—with revisions through January 2010

M1802.2.2

55A—04

Materials for Built-up Roof Coverings

R905.9.2

58—14

Liquefied Petroleum Gas Code

M2201.1

80—2007

Steel Tanks for Oil-burner Fuel—with revisions August 2009

M2201.1

103—2010

Factory-built Chimneys for Residential Type and Building Heating Appliances—with revisions through July 2012

R202, R1005.3, G2430.1

174—04

Household Electric Storage Tank Water Heaters—with revisions through September 2012

M2005.1

180—2012

Liquid-level Indicating Gauges for Oil Burner Fuels and Other Combustible Liquids

M2201.5

181—05

Factory-made Air Ducts and Air Connectors—with revisions through May 2003

M1601.1.1, M1601.4.1

181A—2013

Closure Systems for Use with Rigid Air Ducts and Air Connectors—with revisions through December 1998

M1601.2, M1601.4.1

181B—2013

Closure Systems for Use with Flexible Air Ducts and Air Connectors—with revisions through August 2003

M1601.4.1

217—06

Single- and Multiple-station Smoke Alarms—with revisions through April 2012

R314.1.1, R315.1.1

263—2011

Standards for Fire Test of Building Construction and Materials

Table 302.1(1), Table R302.1(2), R302.2, R302.3, R302.4.1, R302.11.1, Table R312.1(1), R606.2.2

268—2009

Smoke Detectors for Fire Alarm Systems

R314.7.1, R314.7.4, R315.6.4

325—02

Door, Drapery, Gate, Louver and Window Operations and Systems—with revisions through June 2013

R309.4

343—2008

Pumps for Oil-burning Appliances—with revisions through June 2013

M2204.1

378—06

Draft Equipment—with revisions through January 2010

M1804.2.6

441—10

Gas Vents

G2426.1

508—99

Industrial Control Equipment—with revisions through March 2013

M1411.3.1

536—97

Flexible Metallic Hose—with revisions through June 2003

M2202.3

641—2010

Type L, Low-temperature Venting Systems—with revisions through May 2013

R202, R1003.11.5, M1804.2.4, G2426.1

651—2011

Schedule 40 and Schedule 80 Rigid PVC Conduit and Fittings—with revisions through March 2012

G2414.6.3

705—04

Standard for Power Ventilators—with revisions through March 2012

M1502.4.4

723—08

Standard for Test for Surface Burning Characteristics of Building Materials—with revisions through September 2010

R202, R302.9.3, R302.9.4, R302.10.1, R302.10.2, R316.3, R316.5.9, R316.5.11, R507.3.2, R802.1.5, M1601.3, M1601.5.2

726—95

Oil-fired Boiler Assemblies—with revisions through April 2011

M2001.1.1, M2006.1

727—06

Oil-fired Central Furnaces—with revisions through April 2010

M1402.1

729—03

Oil-fired Floor Furnaces—with revisions through August 2012

M1408.1

730—03

Oil-fired Wall Furnaces—with revisions through August 2012

M1409.1

732—95

Oil-fired Storage Tank Water Heaters—with revisions through April 2010

M2005.1

737—2011

Fireplaces Stoves

M1414.1, M1901.2

790—04

Standard Test Methods for Fire Tests of Roof Coverings—with revisions through October 2008

R302.2.2, R902.1

795—2011

Commercial-industrial Gas Heating Equipment—with revisions through September 2012

G2442.1, G2452.1

834—04

Heating, Water Supply and Power Boilers—Electric—with revisions through January 2013

M2001.1.1

842—07

Valves for Flammable Fluids—with revisions through October 2012

M2204.2

858—05

Household Electric Ranges—with revisions through April 2012

M1901.2

875—09

Electric Dry-bath Heaters with revisions through November 2011

M1902.2

896—93

Oil-burning Stoves—with revisions through August 2012

M1410.1

923—2013

Microwave Cooking Appliances

M1504.1

959—2010

Medium Heat Appliance Factory-built Chimneys

R1005.6

1026—2012

Electric Household Cooking and Food Serving Appliances

M1901.2

1040—96

Fire Test of Insulated Wall Construction—with revisions through October 2012

R316.6

1042—2009

Electric Baseboard Heating Equipment—with revisions through June 2013

M1405.1

1256—02

Fire Test of Roof Deck Construction—with revisions through January 2007

R906.1

1261—01

Electric Water Heaters for Pools and Tubs—with revisions through July 2012

M2006.1

1479—03

Fire Tests of Through-Penetration Firestops—with revisions through October 2012

R302.4.1.2

1482—2011

Solid-Fuel-type Room Heaters

R1002.2, R1002.5, M1410.1

1618—09

Wall Protectors, Floor Protectors, and Hearth Extensions—with revisions through May 2013

R1004.2, M1410.2

1693—2010

Electric Radiant Heating Panels and Heating Panel Sets—with revisions through October 2011

M1406.1

1703—02

Flat-plate Photovoltaic Modules and Panels—with revisions through November 2014

R324.3.1, R902.4, R905.16.5, R907.5

1715—97

Fire Test of Interior Finish Material—with revisions through January 2013

R316.6

1738—2010

Venting Systems for Gas-burning Appliances, Categories II, III and IV—with revisions Through May 2011

G2426.1

1741—2010

Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources

R324.3

1777—07

Chimney Liners—with revisions through July 2009

R1003.11.1, R1003.18, G2425.12, G2425.15.4, M1801.3.4

1995—2011

Heating and Cooling Equipment

M1402.1, M1403.1, M1407.1, M1412.1, M1413.1

1996—2009

Electric Duct Heaters—with revisions through November 2011

M1402.1, M1407.1

2034—08

Standard for Single- and Multiple-station Carbon Monoxide Alarms—with revisions through February 2009

R314.1.1, R315.1.1

2075—2013

Standard for Gas and Vapor Detectors and Sensors

R314.7.4, R315.6.1, R315.6.4

2158A—2010

Outline of Investigation for Clothes Dryer Transition Duct

M1502.4.3

2523—09

Standard for Solid Fuel-fired Hydronic Heating Appliances, Water Heaters and Boilers—with revisions through February 2013

M2005.1, M2001.1.1

UL/CSA/ANCE 60335-2-40—2012

Standard for Household and Similar Electrical Appliances, Part 2: Particular Requirements for Motor-compressors

M1403.1, M1412.1, M1413.1

ULC

Underwriters' Laboratories of Canada
7 Underwriters Road
Toronto Ontario Canada M1R 3B4
Standard
reference
number
TitleReferenced
in code
section number

CAN/ULC S 102.2—2010

Standard Methods for Test for Surface Burning Characteristics of Building Materials and Assemblies

R302.10.1, R302.10.2

WDMA

Window & Door Manufacturers Association
2025 M Street, NW Suite 800
Washington DC 20036-3309
Standard
reference
number
TitleReferenced
in code
section number

AAMA/WDMA/CSA 101/I.S2/A440—11

North American Fenestration Standard/Specifications for Windows, Doors and Skylights

R308.6.9, R609.3, N1102.4.3

I.S. 11—13

Industry Standard Analytical Method for Design Pressure (DP) Ratings of Fenestration Products

R308.6.9.1, R609.3.1