CALIFORNIA PLUMBING CODE - MATRIX ADOPTION TABLE
CHAPTER 17 - REFERENCED STANDARDS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
Adopting Agency BSC BSC-CG SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
1 2 1-AC AC SS SS/C 1 2 3 4
Adopt Entire Chapter X X X X X X
Adopt Entire Chapter as amended (amended sections listed below) X X X
Adopt only those sections that are listed below
Chapter/Section
Table 1701.1 X
This state agency does not adopt sections identified with the following symbol:
The Office of the State Fire Marshal's adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.
The standards listed in Table 1701.1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment regulated by this code.These standards are mandatory where required by sections in this code.
     Organization abbreviations referred to in Table 1701.1 are defined in a list found at the end of the table.
TABLE 1701.1
REFERENCED STANDARDS
STANDARD NUMBER STANDARD TITLE
APPLICATION REFERENCED
SECTIONS
AHAM FWD-1-2009
Food Waste Disposers
Appliances 301.2.2, 301.3
APSP 1-2003* Public Swimming Pools
Swimming Pools
Spas, and Hot Tubs
301.2.2, 301.3
ARCSA/ASPE 63-2013*
Rainwater Catchment Systems
Miscellaneous 1602.1, K 104.9.1,
L 504.9.1
ASCE 25-2006*
Earthquake-Actuated Automatic Gas Shutoff Devices
Fuel Gas
301.2.2, 301.3
ASHRAE 90,1-2013*
Energy Standard For Buildings Except Low-Rise Residential
Buildings
Miscellaneous L603.2.1,
Table L 603.3.2
ASHRAE 90.2-2007* Energy-Efficient Design of Low-Rise Residential Buildings Miscellaneous 301.2.2, 301.3
ASME A13.1-2007
(R2013)*
Scheme for the Identification of Piping Systems Piping 301.2.2, 301.3
ASME A 112.1.2-2012* Air Gaps in Plumbing Systems (For Plumbing Fixtures and
Water-Connected Receptors)
Fittings Table 603.2
ASME A112.1.3-2000
(R2010)*
Air Gap Fittings for Use with Plumbing Fixtures, Appliances,and Appurtenances Fittings Table 603.2
ASME A112.3.1-2007
(R2012)*
Stainless Steel Drainage Systems for Sanitary DWV, Storm,
and Vacuum Applications, Above-and Below-Ground (Notes
1 and 7)
Piping, Ferrous 418.1, 705.6.2,
1102.1, Table 701.2
ASME A112.3.4-2013/CSA
B45.9-2013*
Plumbing Fixtures with Pumped Waste and Macerating Toilet
Systems
Fixtures 701.13
ASME A112.4.1-2009* Water Heater Relief Valve Drain Tubes Appliances 301.2.2, 301.3
ASME A112.4.1-2009* Water Closet Personal Hygiene Devices Fixtures 301.2.2, 301.3
ASME A12.4.3-1999
(R2010)*
Plastic Fittings for Connecting Water Closets to the Sanitary
Drainage System
Fittings 301.2.2, 301.3
ASME A112.4.3-2004
(R2010)*
Manually Operated, Quarter-Turn Shutoff Valves for Use in
Plumbing Systems
Valves 606.1
ASME A112.6.1M -1997
(R2012)*
Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures
for Public Use
Fixtures 301.2.2, 301.3
ASME A112.6.2-2000
(R2010)*
Framing-Affixed Supports for Off-the-Floor Water Closets
with Concealed Tanks
Fixtures 301.2.2, 301.3
ASME A112.6.3-2001
(R2007)*
Floor and Trench Drains DWV Components 418.1
ASME A112.6.4-2003
(R2012)*
Roof, Deck, and Balcony Drains DWV Components 1102.1
ASME A112.6.7-2010* Sanitary Floor Sinks Fixtures 421.1
ASME A112.6.9-2005
(R2010)*
Siphonic Roof Drains DWV Components 301.2.2, 301.3
ASME A112.14.1-2003
(R2012)*
Backwater Valves Valves 710.6
ASME A112. 14.3-2000
(R2004)*
Grease Interceptors Fixtures 1014.1
ASME A 112. 14.4-2001
(R2012)*
Grease Removal Devices Fixtures 1014.1
ASME A 112.14.6-2010* FOG (Fats, Oils, and Greases) Disposal Systems Fixtures 1015.2, 1015.4
ASME A112.18.1-
2012/CSA B125.1-2012*
Plumbing Supply Fittings Fittings 402.9,407.2.1,
4.7.2.2, 408.2, 408.3,
417.1, 417.2, 417.3,
417.4, 420.2, 420.3,
603.5.19, L402.5.1,
L402.5.2.1, L402.6,
L402.6.2, L402.6.3
ASME A112.18.2-
2011/CSA B125.2-2011*
Plumbing Waste Fittings Fittings 301.2.2, 301.3
ASME A112.18.3-2002
(R2012)*
Performance Requirements for Backflow Protection Devices
and Systems in Plumbing Fixture Fittings
Backflow Protection 417.3, 417.4
ASME A112. 18.6-
2009/CSA B125.6-2009*
Flexible Water Connectors Piping 604.5, 604.13
ASME A112.18.9-2011* Protectors/Insulators for Exposed Waste and Supplies on
Accessible Fixtures
Miscellaneous 403.3
ASME A112.19.1-
2013/CSA B45.2-2013*
Enamelled Cast Iron and Enamelled Steel Plumbing Fixtures Fixtures 407.1, 408.1, 409.1,
415.1, 420.1
ASME A112.19.2-
2013/CSA B45.1-2013*
Ceramic Plumbing Fixtures Fixtures 407.1 , 408.1, 409.1,
410.1, 411.1, 411.2,
411.2.3, 412.1, 415.1,
420.1, L402.2.1,
L 402.2.2, L 402.3
ASME A112.19.3-
2008/CSA B45.4-2008*
Stainless Steel Plumbing Fixtures Fixtures 407.1, 408.1, 409.1,
410.1, 411.1, 415.1,
420.1, L 402.3.1
ASME A112.19.5-
2011/CSA 845.15-2011*
Flush Valves and Spuds for Water Closets, Urinals, and Tanks Fixtures 413.3
ASME A112.19.7-
2012/CSA B45.10-2012*
Hydromassage Bathtub Systems Fixtures 409.1, 409.6, 413.3
ASME A112.19.10-2003
(R2008)*
Dual Flush Devices for Water Closets Fixtures 301.2.2, 301.3
ASME A 112.19.12-2006
(R2011)*
Wall Mounted, Pedestal Mounted, Adjustable, Elevating,
Tilting, and Pivoting Lavatory, Sink, and Shampoo Bowl
Carrier Systems and Drain Waste Systems
Fixtures 407.1, 420.1
ASME A112.19.14-2013* Six-Liter Water Closets Equipped with a Dual Flushing
Device
Fixtures 411.2.1, L402.2.1
ASME A112.19.15-2012* Bathtubs/Whirlpool Bathtubs with Pressure Sealed Doors Fixtures 409.1
ASME A112.19.19-2006
(R2011)*
Vitreous China Nonwater Urinals Fixtures 412.1, L402.3.1
ASME A112.21.3M-1985
(R2007)*
Hydrants for Utility and Maintenance Use (Note 1) Valves 301.2.2, 301.3
ASME A112.36.2M-1991
(R2012)*
Cleanouts (Note 1) DWV Components 301.2.2, 301.3
ASME B1.20.1-2013* Pipe Threads, General Purpose, Inch Joints 605.1.5, 605.2.3,
605.5.2, 605.12.3,
705.1.3, 705.3.4,
705.4.2, 705.5.3,
1208.5.7, 1309.4.3(2)
ASME B1.20.3-1976
(R2013)*
Dryseal Pipe Threads, (Inch)
Joints 301.2.2, 301.3
ASME B16.1-2010* Gray Iron Pipe Flanges and Flanged Fittings: Classes 25,
125, and 250
Fittings 1208.5.10
ASME B16.3-2011* Malleable Iron Threaded Fittings: Classes 150 and 300 Fittings Table 604.1,
Table 701.2
ASME B16.4-2011* Malleable Iron Threaded Fittings: Classes 150 and 300 Fittings Table 604.1
ASME B16.5-2013* Pipe Flanges and Flanged Fittings: NPS 1/2 through NPS 24
Metric/Inch
Fittings 301.2.2, 301.3
ASME B16.12-2009* Cast Iron Threaded Drainage Fittings (Note 1) Fittings Table 701.2
ASME B16.15-2013* Cast Copper Alloy Threaded Fittings: Classes 125 and 250 Fittings Table 604.1
ASME B16.18-2012* Cast Copper Alloy Solder Joint Pressure Fittings (Note 1) Fittings Table 604.1
ASME B16.20-2012* Metallic Gaskets For Pipe Flanges: Ring-Joint, Spiral-
Wound, and Jacketed
Joints 1208.5.10
ASME B16.21-2011* Nonmetallic Flat Gaskets for Pipe Flanges Joints 301.2.2, 301.3
ASME B16.22-2013* Wrought Copper and Copper Alloy Solder-Joint Pressure
Fittings
Fittings 1309.3, Table 604.1
ASME B16.23-2011* Cast Copper Alloy Solder Joint Drainage Fittings: DWV Fittings Table 701.2
ASME BI6.24-2011 * Cast Copper Alloy Pipe Flanges and Flanged Fittings:
Classes 150,300,600,900, 1500, and 2500
Fittings 301.2.2, 301.3
ASME B16.26-2013* Cast Copper Alloy Fittings for Flared Copper Tubes Fittings 1309.2, Table 604.1
ASME B16.29-2012* Wrought Copper and Wrought Copper Alloy Solder-Joint
Drainage Fittings - DWV (Note 1)
Fittings Table 701.2
ASME B16.33-2012* Manually Operated Metallic Gas Valves for Use in Gas
Piping Systems Up to 175 psi (Sizes NPS 1/2 ,through NPS 2)
Valves 301.2.2, 301.3
ASME B16.34-2013* Valves - Flanged, Threaded, and Welding End Valves 606.1
ASME B16.39-2009* Malleable Iron Threaded Pipe Unions: Classes 150,250 and
300 (Includes Revision Services)
Fittings 301.2.2, 301.3
ASME B16.40-2013* Manually Operated Thermoplastic Gas Shutoffs and Valves
in Gas Distribution Systems
Valves 301.2.2, 301.3
ASME B16.47-2011* Large Diameter Steel Flanges: NPS 26 through NPS 60
Metric/Inch
Fittings 301.2.2, 301.3
ASME B16.50-2013* Wrought Copper and Copper Alloy Braze-Joint Pressure
Fittings
Fittings 1309.3, 1309.3.9
ASME B16.51-2013* Copper and Copper Alloy Press-Connect Pressure Fittings Fittings Table 604.1
ASME B31.1-2012* Power Piping Piping 301.2.2, 301.3
ASME B31.3-2012* Process Piping Piping F1201.1
ASME B36.10M-2004
(R2010)*
Welded and Seamless Wrought Steel Pipe Piping,Ferrous 1208.5.2.1(1)
ASME B36.19-2004
(R2010)*
Stainless Steel Pipe Piping,Ferrous 301.2.2, 301.3
ASME BPVC Section IV-
2013*
Rules for Construction of Heating Boilers Miscellaneous 301.2.2, 301.3
ASME BPVC Section
V111-2013*
Rules for Construction of Pressure Vessels Division 1 Miscellaneous 1314.2(2), 1315.4(2),
E 413.6.2
ASME BPVC Section IX-
2013*
Welding, Brazing, and Fusing Qualifications Certification 225.0, 1307.1,
1309.5.1, 1309.5.2
ASSE 1001-2008* Atmospheric Type Vacuum Breakers Backflow Protection Table 603.2
ASSE 1002-2008* Anti-Siphon Fill Valves for Water Closet Tanks Backflow Protection 413.3, Table 603.2
ASSE 1003-2009* Water Pressure Reducing Valves for Domestic Water
Distribution Systems
Valves 301.2.2,303
ASSE 1004-2008* Backflow Prevention Requirements for Commercial
Dishwashing Machines
Backflow Protection 414.2
ASSE 1008-2006* Plumbing Aspects of Residential Food Waste Disposer Units Appliances 419.1
ASSE 1010-2004* Water Hammer Arresters Water Supply Component
609.10
ASSE 1011-2004* Hose Connection Vacuum Breakers Backflow Protection Table 603.2
ASSE 1012-2009* Backflow Preventers with an Intermediate Atmospheric Vent Backflow Protection 301.2.2, 301.3
ASSE 1013-2011* Reduced Pressure Principle Backflow Preventers and
Reduced Pressure Principle Fire Protection Backflow Preventers
Backflow Protection Table 603.2
ASSE 1014-2005* Backflow Prevention Devices for Hand-Held Shower Backflow Protection 417.3
ASSE 1015-2011* Double Check Backflow Prevention Assemblies and Double
Check Fire Protection Backflow Prevention Assemblies
Backflow Protection Table 603.2
ASSE 1016-2011/
ASME A112.1 016-201/
CSA B125.16-2011*
Automatic Compensating Valves for Individual Showers and
Tub/Shower Combinations
Valves 408.3, L 402.6.3
ASSE 1017-2009* Temperature Actuated Mixing Valves for Hot Water Distribution
Systems
Valves 301.2.2, 301.3
ASSE 1018-2001* Trap Seal Primer Valves - Potable Water Supplied Valves 301.2.2, 301.3
ASSE 1019-2011* Wall Hydrant with Backflow Protection and Freeze Resistance Backflow Protection Table 603.2
ASSE 1020-2004* Pressure Vacuum Breaker Assembly
Backflow Protection Table 603.2
ASSE 1022-2003* Backflow Preventer for Beverage Dispensing Equipment Backflow Protection 603.5.12, Table 603.2
ASSE 1023-1979 Hot Water Dispensers Household Storage Type - Electrical Appliances 301.2.2,301.3
ASSE 1024-2004* Dual Check Backflow Preventers Backflow Protection 301.2.2,301.3
ASSE-1032-2004 (R2011)* Dual Check Valve Type Backflow Preventers for carbonated
Beverage Dispensers, Post Mix Type
Backflow Protection 301.2.2,301.3
ASSE 1035-2008* Laboratory Faucet Backflow Preventers Backflow Protection 301.2.2,301.3
ASSE 1037-1990 Pressurized Flushing Devices (Flushometers) for Plumbing
Fixtures
Backflow Protection 413.2
ASSE 1044-2001* Trap Seal Primer Devices - Drainage Types and Electronic
Design Types
DWV Components
301.2.2,301.3
ASSE 1047-2011* Reduced Pressure Detector Fire Protection Backflow Prevention
Assemblies
Backflow Protection Table 603.2
ASSE 1048-2011* Double Check Detector Fire Protection Backflow Prevention
Assemblies
Backflow Protection Table 603.2
ASSE 1052-2004* Hose Connection Backflow Preventers Backflow Protection Table 603.2
ASSE 1053-2004 Dual Check Backflow Preventer Wall Hydrants - Freeze
Resistant Type
Backflow Protection Table 603.2
ASSE 1055-2009* Chemical Dispensing Systems Backflow Protection 301.2.2, 301.3
ASSE 1056-2013* Spill Resistant Vacuum Breaker Assemblies Backflow Protection Table 603.2
ASSE 1057-2012 Freeze Resistant Sanitary Yard Hydrants with Backflow
Protection
Backflow Protection Table 603.2
ASSE 1060-2006* Outdoor Enclosures for Fluid Conveying Components Miscellaneous 603.4.7
ASSE 1061-2011* Push-Fit Fittings Fittings 605.1.3.3, 605.2.1,
Table 604.1
ASSE 1062-2006* Temperature Actuated, Flow, Reduction (TAFR) Valves for
Individual Fixture Fittings
Valves 301.2.2,301.3
ASSE 1066-1997 Individual Pressure Balancing In-Line Valves for Individual
Fixture Fittings (Note 6)
Valves 301.2.2,301.3
ASSE 1069-2005* Automatic Temperature Control Mixing Valves Valves 408.3
ASSE 1070-2004* Water Temperature Limiting Devices Valves 407.3,409.4, 410.3
ASSE 1071-2012 Temperature Actuated Mixing Valves for Plumbed
Emergency Equipment
Valves 301.2.2,301.3
ASSE 1079-2012 Dielectric Pipe Unions Joints 605.15,605.16.1,
605.16.3
ASSE Series 5000-2009* Cross-Connection Control Professional Qualifications Certification 603.2
ASSE Series 6000-2012* Professional Qualifications Standard for Medical Gas
Systems Personnel
Certification 1306.1,1319.12.2
ASSE Series 7000-2013* Residential Potable Water Fire Protection System Installers &
Inspectors for One and Two Family Dwellings
Miscellaneous 612.1
ASTMA47/A47M-1999
(R2009)
Ferritic Malleable Iron Castings Piping, Ferrous 301.2.2,301.3
ASTM A48/A48M-2003
(R2012)
Gray Iron Castings Piping, Ferrous 301.2.2,301.3
ASTM A53/A53M-2012 Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and
Seamless
Piping, Ferrous 1208.5.2.1(2), Table
604.1, Table 701.2
ASTM A74-2013a Cast Iron Soil Pipe and Fittings (Notes 1 and 7) Piping, Ferrous Table 701.2
ASTM A106/A106M-2013 Seamless Carbon Steel Pipe for High-Temperature Service Piping, Ferrous 1208.5.2.1(3)
ASTM A126-2004 (R2009) Gray Iron Castings for Valves, Flanges, and Pipe Fittings Piping, Ferrous 301.2.2,301.3
ASTM A197/A197M-2000
(R2011)
Cupola Malleable Iron Piping, Ferrous 301.2.2,301.3
ASTM A254/A254M-2012 Copper-Brazed Steel Tubing Piping, Ferrous 1208.5.3.1, E 409.1
ASTM A269-2013 Seamless and Welded Austenitic Stainless Steel Tubing for
General Service
Piping, Ferrous F 801.2, Table 604.1
ASTM A312/A312M
Seamless, Welded, and Heavily Cold Worked Austenitic
Stainless Steel Pipes
Piping, Ferrous Table 604.1
ASTM A377 -2003
(R2008)e1
Ductile-Iron Pressure Pipe Piping, Ferrous 301.2.2, 301.3
ASTM A4791 A479M-
2013b
Stainless Steel Bars and Shapes for Use in Boilers and Other
Pressure Vessels
Piping, Ferrous F 801.3
ASTM A518/A518M-1999
(R2012)
Corrosion-Resistant High-Silicon Iron Castings Piping, Ferrous 301.2.2, 301.3
ASTM A536-1984 (R2009) Ductile Iron Castings Piping, Ferrous 301.2.2, 301.3
ASTM A653/A653M-2013 Steel Sheet,Zinc-Coated (Galvanized) or Zinc-Iron Alloy-
Coated (Galvannealed) by the Hot-Dip Process_
Piping, Ferrous 301.2.2, 301.3
ASTM A733-2013 Welded and Seamless Carbon Steel and Austenitic Stainless
Steel Pipe Nipples
Piping, Ferrous 301.2.2, 301.3
ASTM A861-2004 (R2013)
High-Silicon Iron Pipe and Fittings (Note 1) Piping, Ferrous 811.2
ASTM A888-2013a Hubless Cast Iron Soil Pipe and Fittings for Sanitary and
Storm Drain, Waste, and Vent Piping Applications (Note 7)
Piping, Ferrous Table 701.2
ASTM A1045-2010 Flexible Poly (Vinyl Chloride) (PVC) Gaskets used in
Connection of Vitreous China Plumbing Fixtures to Sanitary
Drainage Systems
Piping, Ferrous 301.2.2, 301.3
ASTM A1056-2012 Cast Iron Couplings used for Joining Hubless Cast Iron Soil
Pipe and Fittings
Piping, Ferrous 705.2.2
ASTM B29-2003 (R2009) Refined Lead Joints 301.2.2, 301.3
ASTM B32-2008 Solder Metal (Note 2) Joints 60S. 1.4, 705.3.3,
1309.2
ASTM B42-2010 Seamless Copper Pipe, Standard Sizes Piping, Copper Alloy Table 604.1
ASTM B43-2009 Seamless Red Brass Pipe, Standard Sizes Piping, Copper Alloy Table 604.1,
Table 701.2
ASTM B75/B75M-2011 Seamless Copper Tube (Note 7) Piping, Copper Alloy Table 604.1,
Table 701.2
ASTM B88-2009 Seamless Copper Water Tube Piping, Copper Alloy 604.4, 903.2.3,
1208.5.3.2,
1308.5(1)(a), E 409.1,
Table 604.1
ASTM B135-2010 Seamless Brass Tube Piping, Copper Alloy Table 604.1
ASTM B152/B152M-2013 Copper Sheet, Strip, Plate, and Rolled Bar Miscellaneous 408.7.4
ASTM B187/B187M-2011
Copper, Bus Bar, Rod, and Shapes and General Purpose Rod,
Bar, and Shapes
Miscellaneous 301.2.2,301.3
ASTM B210-2012 Aluminum and Aluminum-Alloy Drawn Seamless Tubes Piping, Ferrous 1208.5.3.3
ASTM B241M-
2012e1
Aluminum and Aluminum-Alloy Seamless Pipe and Seamless Extruded Tube Piping, Ferrous 1208.5.2.3, 1208.5.3.3
ASTM B251-2010 General Requirements for Wrought Seamless Copper and Copper-Alloy Tube (Note 7) Piping, Copper Alloy Table 604.1,
Table 701.2
ASTM B280-2013 Seamless Copper Tube for Air Conditioning and Refrigeration
Field Service
Piping, Copper Alloy 1208.5.3.2,
1308.5(1)(b), E409.1
ASTM B302-2012 Threadless Copper Pipe, Standard Sizes (Note 7) Piping, Copper Alloy Table 604.1,
Table 701.2
ASTM B306-2013 Copper Drainage Tube(DWV) (Note 7)
Piping, Copper Alloy 9020102, Table 701.2
ASTM B370-2012 Copper Sheet and Strip for Building Construction Miscellaneous 301.2.2, 301.3
ASTM B447-2012a Welded Copper Tube Piping, Copper Alloy Table 604.1
ASTM B584-20 13 copper Alloy Sand Castings for General Applications (Note 3) Piping, Copper Alloy 301.2.2, 301.3
ASTM B587-2012 Welded Brass Tube Piping, Copper Alloy 301.2.2, 301.3
ASTM B687-19999 (R2011) Brass, Copper, and Chromium-Plated Pipe Nipples
Piping, Copper Alloy 301.2.2, 301.3
ASTM B813-2010 Liquid and Paste Fluxes for Soldering of Copper and Copper
Alloy Tube
Joints 605.1.4, 705.3.3
ASTM B819-2000 (R2011)
Seamless Copper Tube for Medical Gas Systems Piping, Copper Alloy 1308.4,
1308.5(1)(c)
ASTM B828-2002 (R2010) Making Capillary Joints by Soldering of Copper and Copper
Alloy Tube and Fittings
Joints 605.1.4.705.3.3,
1309.2
ASTM C4-2004 (R2009) Clay Drain Tile and Perforated Clay Drain Tile Piping, Non-Metallic Table 1101.4.6
ASTM C14-2011 Nonreinforced Concrete Sewer, Storm Drain, and Culvert
Pipe (Note 7)
Piping, Non-Metallic 301.2.2, 301.3
ASTM C412-2011
Concrete Drain Title
Piping, Non-Metallic 301.2.2, 301.3
ASTM C425-2004 (R2013) Compression joints for Vitrified Clay Pipe and Fittings Joints 705.7.1
ASTM C443-2012 Joints for Concrete Pipe• and Manholes, Using Rubber
Gaskets
Joints 301.2.2, 301.3
ASTM C444-2003 (R2009) Perforated Concrete Pipe Piping, Non-Metallic 301.2.2, 301.3
ASTM C478-2013
Precast Reinforced Concrete Manhole Sections
Miscellaneous 301.2.2, 301.3
ASTM C564-2012 Rubber Gaskets for Cast Iron Soil Pipe and Fittings Joints 705.7.2
ASTM C700-2013 Vitrified Clay Pipe, Extra Strength, Standard Strength, and
Perforated (Note 7)
Piping, Non-Metallic Table 701.2,
Table 1101.4.6,
ASTM C1053-2000
(R20J 0)
Borosilicate Glass Pipe and Fittings for Drain, Waste and
vent (DWV) Applications (Note 1)
Piping, Non-Metallic 811.2
ASTM C1173-2010e1 Flexible Transition Couplings for Underground Piping
Systems
Joints 705.9
ASTM C1227=2013 Precast Concrete Septic Tanks DWV Components 301.2.2, 301.3
ASTM C1277-20J2 Shielded Couplings Joining Hubless Cast Iron Soil Pipe and
Fittings
DWV Components 301.2.4, 705.2.2
ASTM C1440-2008
(R2013)e1
Thermoplastic Elastomeric (TPE) Gasket Materials for Drain,
Wast, and Vent (DWV), Sewer, Sanitary and Storm
Plumbing Systems
Joints 301.2.2, 301.3
AS1N1 C1460-2012 Shielded Transition Couplings for Use With Dissimilar DWV
Pipe and Fittings Above Ground
Joints 705.9
AS1N1 C1461-2008
(R2013)
Mechanical Couplings Using Thermoplastic Elastomeric
(TPE) Gaskets for Joining Drain, Waste, and Vent (DWV),
Sewer, Sanitary, and Storm Plumbing Systems for Above and
Below Ground Use
Joints 705.9
ASTM C1540-2011
Heavy Duty Shielded Couplings Joining Hubless Cast Iron
Soil Pipe and Fittings
Joints 705.2.2
ASTM C1563-2004 Gaskets for Use in Connection with Hub & Spigot Cast Iron
Soil Pipe and Fittings for Sanitary Drain, Waste, Vent, and Storm Piping Applications
Joints 705.2.2
ASTM D1253-2014 Standard Test Method for Residual Chlorine in Water Miscellaneous 1504.10.6, 1602.9.4.1
ASTM D1784-2011 Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated
Poly (Vinyl Chloride) (CPVC) Compounds
Piping, Plastic 301.2.2, 301.3
ASTM D1785-2012* Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80,
and 120 (Note 7)
Piping, Plastic 1308.5, Table 604.1,
Table 701.2
ASTM D2235-2004
(R2011)*
Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS)
Plastic Pipe and Fittings
Joints 705.1.2
ASTM D2239-2012a*
Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on
Controlled Inside Diameter
Piping, Plastic Table 604.1
ASTM D2241-2009* Poly (Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR
Series)
Piping, Plastic Table 604.1
ASTM D2321-2011* Underground Installation Of Thermoplastic Pipe for Sewers
and Other Gravity-Flow Applications (Note 7)
Piping, Plastic 301.2.2, 301.3
ASTM D2464-2013* Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings,
Schedule 80 (Note 1)
Fittings Table 604.1
ASTM D2466-2013* Poly-(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule
40 (Note 1)
Fittings 1309.2, Table 604.1
ASTM D2467-2013a* Poly-(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule
80 (Note 1)
Fittings 1309.2, Table 604.1
ASTM D2513-2013* Polyethylene (PE) Gas Pressure Pipe, Tubing, and Fittings
(Note 1)
Piping, Plastic 1208.5.4,
1208.5.4.2.2,
1208.5.9.2,
1210.1.7.1(1), E 409.3
ASTM D2517-2006
(R2011)*
Polyethylene (PE) Gas Pressure Pipe, Tubing, and Fittings Piping, Plastic E 409.3
ASTM D2564-2012* Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic
Piping Systems
Joints 605.12.2, 705.5.2
ASTM D2609-2002
(R2008)*
Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe
(Note 1)
Fittings Table 604.1
ASTM D2657-2007* Heat Fusion Joining of Polyolefin Pipe and Fittings (Note 1) Joints 301.2.2, 301.3
ASTM D2661-2011* Acrylonitrile-Butadiene-Styrene (Abs) Scedule 40 Plastic
Drain, Waste, and Vent Pipe and Fittings (Notes 1 and 7)
Piping, Plastic Table 701.2
ASTM D2665-2012* Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent
Pipe and Fittings (Note 7)
Piping, Plastic Table 701.2
ASTM D2672 1996a
(R2009)*
Joints for IPS PVC Pipe Using Solvent Cement Joints 1309.2
ASTM D2680-2001
(R2009)*
Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl
Chloride) (PVC) Composite Sewer Piping (Note 7)
Piping, Plastic Table 701.2
ASTM D2683-2010e1* Socket-Type Polyethylene Fittings for Outside Diameter-
Controlled Polyethylene Pipe and Tubing
Fittings Table 604.1
ASTM D2729-2011* Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings (Notes
1 and 7)
Piping, Plastic Table 1101.4.6
ASTM D2737-2012a* Polyethylene (PE) Plastic Tubing Piping, Plastic Table 604.1
ASTM D2751-2005* Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and
Fittings (Notes 1 and 7)
Piping, Plastic 301.2.2, 301.3
ASTM D2774-2012* Underground Installation of Thermoplastic Pressure Piping Piping, Plastic 301.2.2, 301.3
ASTM D2846/D2846M-
2009be1*
Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and
Cold-Water Distribution Systems
Piping, Plastic 605.2.2, 605.3.1,
1308.5, 1309.2,
Table 604.1
ASTM D2855-1996
(R2010)*
Making Solvent-Cemented Joints with Poly (Vinyl Chloride)
(PVC) Pipe and Fittings
Joints 301.2.2, 301.3
ASTM D2996-2001
(R2007)e1*
Filament-Wound "Fiberglass" (Glass-Fiber-Reinforced Ther-
mosetting-Resin) Pipe
Piping, Plastic 301.2.2, 301.3
ASTM D3034-2008* Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and
Fittings (Note 7)
Piping, Plastic 301.2.2, 301.3
ASTM D3035-2012e2* Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled
Outside Diameter
Piping, Plastic Table 604.1
ASTM D3122-1995
(R2009)*
Solvent Cements for Styrene-Rubber (SR) Plastic Pipe and
Fittings
Joints 301.2.2, 301.3
ASTM D3138-2004
(R2011)*
Solvent Cements for Transition Joints Between Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC)
Non-Pressure Piping Components
Joints 705.8.4
ASTM D3139-1998
(R2011)*
Joints for Plastic Pressure Pipes Using Flexible Elastomeric
Seals
Joints 605.12.1
ASTM D3212-2007
(R2013)*
Joints for Drain and Sewer Plastic Pipes Using Flexible
Elastomeric Seals
Joints 705.1.1, 705.5.1
ASTM D3261-2012e1* Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene
(PE) Plastic Pipe and Tubing
Fittings Table 604.1
ASTM D3311-2011* Drain, Waste, and Vent (DWV) Plastic Fittings Patterns (Note 1) Fittings 301.2.2, 301.3
ASTM D3965-2011 Rigid Acrylonitrile-Butadiene-Styrene (ABS) Materials for Pipe and Fittings Piping, Plastic 301.2.2, 301.3
ASTM D4068-2009* Chlorinated Polyethylene (CPE) Sheeting for Concealed
Water-Containment Membrane
Miscellaneous 408.7.2
ASTM D4101-2011 Polypropylene Injection and Extrusion Materials Miscellaneous 301.2.2, 301.3
ASTM D4551-2012* Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed
Water-Containment Membrane
Miscellaneous 408.7.1
ASTM D6104-1997
(R2011)
Determining the Performance of Oil/Water Separators
Subjected to Surface Run-Off
Miscellaneous 301.2.2, 301.3
ASTM E84-2013a* Surface Burning Characteristics of Building Materials Miscellaneous 701.2(2), 903.1(2),
1101.4
ASTM E119-2012a* Fire Tests of Building Construction and Materials Miscellaneous 1404.3, 1405.3
ASTM E814-2013a* Fire-Tests of Penetration Firestop Systems Miscellaneous 208.0. 222.0. 1404.3.
1405.3
ASTM F40.2.-2005
(R2012)*
Safe Handling of Solvent Cements, Primers, and Cleaners Used for Joining Thermoplastic Pipe and Fittings Joints 301.2.2, 301.3
ASTM F405-2013* Corrugated Polyethylene (PE) Pipe and Fittings Piping, Plastic Table 1101.4.6
ASTM F409-2012* Thermoplastic Accessible and Replaceable Plastic Tube and
Tubular Fittings (Note 1)
Piping, Plastic 301.2.2, 301.3
ASTM F437-2009* Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic
Pipe Fittings, Schedule 80
Fittings Table 604.1
ASTM F438-2009* Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 40
Fittings 1309.2, Table 604.1
ASTM F439-2013* Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe
Fittings, Schedule 80
Fittings 1309.2, Table 604.1
ASTM F441/F441M-
2013e1*
Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe
Schedules 40 and 80
Piping, Plastic 1308.5, Table 604.1
ASTM F442/F442M-
2013e1*
Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe
(SDR-PR)
Piping, Plastic 605.2.2, Table 604.1
ASTM F446-1985 (R2009) Grab Bars and Accessories Installed in the Bathing Area Miscellaneous 301.2.2, 301.3
ASTM F480-2012*
Thermoplastic Well Casing Pipe and Couplings Made in
Standard Dimension Ratios (SDR), SCH 40 and SCH SO
Piping, Plastic 301.2.2, 301.3
ASTM F493-2010* Solvent Cements for Chlorinated Poly (Vinyl Chloride)
(CPVC) Plastic Pipe and Fittings
Joints 605.2.2, 605.3.1,
1309.2
ASTM F628-2012e1* Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core (Notes 1 and 7) Piping, Plastic Table 701.2
ASTM F656-2010* Primers for Use in Solvent Cement Joints of Poly (Vinyl
Chloride) (PVC) Plastic Pipe and Fittings
Joints 605.2.2, 605.3.1,1,
605.12.2,70S.5.2
ASTM F667-2012* 3 through 24 in. Corrugated Polyethylene Pipe and Fittings Piping, Plastic 301.2.2, 301.3
ASTM F714-2013*
Polyethylene (PE) Plastic Pipe ()DR-PR) Based on Outside
Diameter
Piping, Plastic Table 701.2
ASTM F794-2003
(R2009)*
Poly (Vinyl Chloride) (PVC)Profile Gravity Sewer Pipe and
Fittings Based on Controlled Inside Diameter (Note 7)
Piping, Plastic Table 701.2
ASTM F81O~2012* Smoothwall Polyethylene (PE) Pipe for Use in Drainage and
Waste Disposal Absorption Fields
Piping, Plastic 301.2.2, 301.3
ASTM F876-2013a* Crosslinked Polyethylene (PEX) Tubing Piping, Plastic 605.9.1, Table 604.1
ASTM F877-2011a* Crosslinked Polyethylene (PEX) Hot- and Cold-Water Distribution
systems
Piping, Plastic Table 604.1
ASTM F891-2010* Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a
Cellular Core (Note 7)
Piping, Plastic Table 701.2
ASTM F894-2013* Polyethylene (PE) Large Diameter Profile Wall Sewer and
Drain Pipe (Note 7)
Piping, Plastic 301.2.2, 301.3
ASTM F949-2010* Poly (Vinyl Chloride) (PVC) Corrugated Sewer Pipe with a
Smooth Interior and Fittings (Note 7)
Piping, Plastic 301.2.2, 301.3
ASTM F1055-2013* Electrofusion Type Polyethylene Fittings for Outside Diameter
Controlled Polyethylene and Crosslinked Polyethylene
(PEX) Pipe and Tubing
Fittings Table 604.1
ASTM F1216~2009* Rehabilitation of Existing Pipelines and Conduits, by the
Inversion and Curing of a Resin-Impregnated Tube
Piping, Plastic 715.3
ASTM F1281-2011* Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene
(PEX-AL-PEX) Pressure Pipe
Piping, Plastic Table 604.1
ASTM F1282-2010* Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe
Piping, Plastic Table 604.1
ASTM F1336-2007* Poly (Vinyl Chloride) (PVC) Gasketed Sewer Fittings
Fittings 301.2.2, 301.3
ASTM F1412-2009* Polyolefin Pipe and Fittings for Corrosive Waste Drainage
Systems
Piping, Plastic 811.2
ASTM F1476-2007
(R2013)*
Performance of Gasketed Mechanical Couplings for Use in
Piping Applications
Joints 301.2.2, 301.3
ASTM F1488-2009e1* Coextruded Composite Pipe (Note 7) Piping, Plastic Table 701.2
ASTM F1499-2012* Coextruded Composite Drain, Waste, and Vent Pipe (DWV) Piping, Plastic 301.2.2, 301.3
ASTM F1673-2010* Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage
Systems
Piping, Plastic 811.2
ASTM F1743-2008* Rehabilitation of Existing Pipelines and Conduits by Pulled-
in-Place Installation of Cured-in-Place Thermosetting Resin
Pipe (CIPP)
Piping, Plastic 301.2.2, 301.3
ASTM F1807-2013a* Metal Insert Fittings Utilizing a Copper Crimp Ring for
SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9
Polyethylene of Raised Temperature (PE-RT) Tubing
Fittings Table 604.1
ASTM F1866-2007* Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage
and DWV Fabricated Fittings
Fittings Table 701.2
ASTM F1924-2012* Plastic Mechanical Fittings for Use on Outside Diameter
Controlled Polyethylene Gas Distribution Pipe and Tubing
Fittings 301.2.2, 301.3
ASTM F1948-2012* Metallic Mechanical Fittings for Use on Outside Diameter
Controlled Thermoplastic Gas Distribution Pipe and Tubing
Fittings 301.2.2, 301.3
ASTM F1960-2012 * Cold Expansion Fittings with PEX Reinforcing Rings for Use
with Cross-linked Polyethylene (PEX) Tubing
Fittings Table 604.1
ASTM F1961-2009* Metal Mechanical Cold Flare Compression Fittings with Disc
Spring for Crosslinked Polyethylene (PEX) Tubing
Fittings Table 604.1
ASTM F1970-2012e1* Special Engineered Fittings, Appurtenances or Valves for Use
in Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl
Chloride) (CPVC) Systems
Piping, Plastic 606.1, Table 604.1
ASTM F1973-2013e1* Factory Assembled Anodeless Risers and Transition Fittings
in Polyethylene (PE) and Polyamide II (PA11) and
Polyamide 12 (PA12) Fuel Gas Distribution Systems
Fuel Gas 1210.1.7.1(2)
ASTM F1974-2009* Metal Insert Fittings for Polyethylene/ Aluminum/Polyethylene
and Crosslinked Polyethylene/Aluminum/Crosslinked
Polyethylene Composite Pressure Pipe
Fittings 605.7.1, 605.10.1,
Table 604.1
ASTM F1986-2001
(R2011)*
Multilayer Pipe Type 2, Compression Fittings, and Compression
Joints for Hot and Cold Drinking-Water Systems
Fittings 301.2.2, 301.3
ASTM F2080-2012* Cold-Expansion Fittings with Metal Compression-Sleeves for
Cross-linked Polyethylene (PEX) Pipe
Fittings Table 604.1
ASTM F2098-2008* Stainless Steel Clamps for Securing SDR9 Cross-linked
Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert
Fittings
Joints Table 604.1
ASTM F2159-2011* Plastic Insert Fittings Utilizing a Copper Crimp Ring for
SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9
Polyethylene of Raised Temperature (PE-RT) Tubing
Joints Table 604.1
ASTM F2165-2013* Flexible Pre-Insulated Piping Piping, Plastic 301.2.2, 301.3
ASTM F2206-2011*
Fabricated Fittings of Butt-Fused Polyethylene (PE) Plastic
Pipe, Fittings, Sheet Stock, Plate Stock, or Block Stock
DWV Components 301.2.2, 301.3
ASTM F2262-2009* Crosslinked Polyethylene/Aluminum! Crosslinked Polyethylene
Tubing OD Controlled SDR9
Piping, Plastic Table 604.1
ASTM F2306/F2306M-
2013*
Specification for 12 to 60 in. [300 to 1500 mm] Annular
Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings
for Gravity-Flow Storm Sewer and Subsurface Drainage
Applications
Piping, Plastic 301.2.2, 301.3
ASTM F2389-2010* Pressure-Rated Polypropylene (PP) Piping Systems Piping, Plastic 605.11.1,606.1,
Table 604.1
ASTM F2434-2009* Metal Insert Fittings Utilizing a Copper Crimp Ring for
SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene
(PEX-AL-PEX) Tubing
Fittings 605.10.1, Table 604.1
ASTM F2509-2012*
Field-Assembled Anodeless Riser Kits for Use on Outside
Diameter Controlled Polyethylene Gas Distribution Pipe and
Tubing
Fuel Gas 1210.1.7.1(3)
ASTM F2620-2012* Standard Practice for Heat Fusion Joining of Polyethylene
Pipe and Fittings
Joints 605.6.1.1, 605.6.1.3
ASTM F2735-2009* [Plastic Insert Fittings for SDR9 Cross-linked Polyethylene
(PEX) and Polyethylene of Raised Temperature (PE-RT)
Tubing
Fittings Table 604.1
ASTM F2769-2010* Polyethylene of Raised Temperature (PE-RT) Plastic Hot and
Cold-water Tubing and Distribution Systems
Piping and Fittings,
Plastic
Table 604.1
ASTM F2831-2012* Internal Non Structural Epoxy Barrier Coating Material Used
in Rehabilitation of Metallic Pressurized Piping Systems
Miscellaneous 320.1
ASTM F2855-2012* Chlorinated Poly (Vinyl Chloride)/Aluminum/Chlorinated
Poly (Vinyl Chloride) (CPVC/ALlCPVC) Composite
Pressure Tubing
Piping, Plastic 605.3.1, Table 604.1
AWS A5.8-2011*
Filler Metals for Brazing and Braze Welding
Joints 605.1.1, 705.3.1,
1309.3.2
AWS A5.9-2012* Bare Stainless Steel Welding Electrodes and Rods
Joints 605.13.2
AWS B2.2/B2.2M-2010* Brazing Procedure and Performance Qualification
Certification 1307.1
AWS B2.4-2012* Welding Procedure and Performance Qualification for
Thermoplastics
Joints Certification 301.2.2, 301.3
AWWA C110-2012* Ductile-Iron and Gray-iron Fittings Fittings Table 604.1
AWWA C111-2012* Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and
Fittings
Joints 605.4.1, 605.4.2
AWWA C151-2009* Ductile-Iron Pipe, Centrifugally Cast Piping, Ferrous Table 604.1
AWWA C153-2011* Ductile-Iron Compact Fittings
Fittings Table 604.1
AWWA C203-2008*
Coal-Tar Protective Coatings and Linings for Steel Water
Pipelines - Enamel and Tape ~ Hot Applied
Miscellaneous 301.2.2, 301.3
AWWA C210-2007*
Liquid-Epoxy Coating Systems for the Interior and Exterior
of Steel Water Pipelines
Miscellaneous 604.9
AWWA C213-2007* Fusion-Bonded Epoxy Coating for the Interior and Exterior
of Steel Water Pipelines
Miscellaneous 301.2.2, 301.3
AWWA C215-2010* Extruded Polyolefin Coatings for the Exterior of Steel Water
Pipelines
Miscellaneous 301.2.2, 301.3
AWWA C500-2009* Metal-seated Gate Valves for Water Supply Service
Valves 606.1
AWWA C504-2010* Rubber Seated Butterfly Valves, 3 in. (75 mm) through 72 in.
(1800 mm)
Valves 606.1
AWWA C507-2011* Ball Valves, 6 in. through 60 in. (150 mm through 1,500 mm) Valves 606.1
AWWA C510-2007* Double Check Valve Backflow Prevention Assembly Backflow Protection Table 603.2
AWWA C511-2007 Reduced-Pressure Principle Backflow Prevention Assembly
Backflow Protection Table 603.2
AWWA C606-2011* Grooved and Shouldered Joints
Joints 301.2.2, 301.3
AWWA C900-2007* Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated
Fittings, 4 in. through 12 in. (100 mm through 300 mm), for
Water Transmission and Distribution
Piping, Plastic
Table 604.1
AWWA C901-2008* Polyethylene (PE) Pressure pipe and Tubing, 1/2 in. (13 mm)
through 3 in. (76 mm), for Water Service
Piping, Plastic Table 604.1
AWWA C904-2006* Cross-Linked Polyethylene (PEX) Pressure Pipe, 112 in. (12
mm) through 3 in. (76 mm), for Water Service
Piping, Plastic Table 604.1
AWWA C907-2012* Injection-Molded Polyvinyl Chloride(PVC) Pressure
Fittings,4in, Through 12 in, (100 mm through 300 mm), for
Water, Wastewater, and Reclaimed Water Service
Fittings 301.2.2, 301.3
CGA C-9-2013 Standard Color Marking of Compressed Gas Containers for
Medical Use
Miscellaneous 301.2.2, 301.3
CGA G-4.1-2009
Cleaning Equipment for Oxygen Service Miscellaneous 1308.2, 1311.1
CGA S-1.3-2008 Pressure Relief Device Standards-Part 3-Stationary Storage
Containers for Compressed Gases
Fuel Gas F 501.8
CGA V-1-2013 Compressed Gas Cylinder Valve Outlet and Inlet Connections Valves F 601.6, F 701.4
C1SP1 301-2012 Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm
Drain, Waste, and Vent Piping Applications (Notes 1 and 7)
Piping, Ferrous
Table 701.2
C1SP1 310-2012 Couplings for Use in Connection with Hubless Cast Iron Soil
Pipe and Fittings for Sanitary and Storm Drain, Waste, and
Vent Piping Applications
Joints 301.2.4, 705.2.2
CSA A257-2009 Concrete Pipe and Manhole Sections Piping 301.2.2, 301.3
CSAB45,0-2002 (R2008)
General Requirements for Plumbing Fixtures Fixtures 301.2.2, 301.3
CSA B45.5-2011/IAPMO Plastic Plumbing Fixtures Fixtures 407.1, 408.1, 409.1,
411.1, 412.1, 420.1,
L 402.3, L 402.3.1
CSA B45.8-2013/IAPMO
Z403-2013*
Terrazzo, Concrete, and Natural Stone Plumbing Fixtures
Fixtures 301.2.2, 301.3
CSA B45.11-2011/L4PMO
Z401-2011*
Glass Plumbing Fixtures Fixtures 407.1
CSA B45.12-2013/IAPMO
Z402-2013*
Aluminum and Copper Plumbing Fixtures Fixtures 301.2.2, 301.3
CSA B64-2011
Backflow Preventers and Vacuum Breakers Backflow Protection 301.2.2, 301.3
CSA B64.1.1-2011 Atmospheric Vacuum Breakers (AVB) Backflow Protection Table 603.2
CSA B64.1.2-2011 Pressure Vacuum Breakers (PVB) Backflow Protection Table 603.2
CSA B64.2-2011 Hose Connection Vacuum Breakers (HCVB)
Backflow Protection 301.2.2, 301.3
CSA B64.2.1.1-2011 Hose Connection Dual Check Vacuum Breakers (HCDVB) Backflow Protection Table 603.2
CSA B64.4-2011 Reduced Pressure Principle (RP) Backt10w Preventers Backflow Protection Table 603.2
CSA B64.4.1-2011 Reduced Principle Backflow Preventers for Fire
Protection Systems (RPF)
Backflow Protection Table 603.2
CSA B64.5-2011 Double Check Valve (DVCA) Backflow Preventers
Backflow Protection Table 603.2
CSA B64.5.1-2011 Double Check Valve Backflow Preventers for Fire Protection
Systems (DVCAF)
Backflow Protection Table 603.2
CSA B64.7-2011 Laboratory Faucet Vacuum Breakers (LFVB) Backflow Protection 301.2.2, 301.3
CSA B66-2010 Design, Material, and Manufacturing Requirements for
Prefabricated Septic Tanks and Sewage Holding Tanks
DWV Components 301.2.2, 301.3
CSA B79-2008 (R2013)
Commercial and Residential Drains and Cleanouts DWV Components 418.1
CSA B125.3-2012 Plumbing Fittings Fittings 407.3,409.4,410.3,
413.2,413.3,606.1,
Table 603.2
CSA B128.1-2006/B 128.2-
2006 (R2011)
Design and Installation of Non-Potable Water Systems/Main-
tenance and Field Testing of Non-Potable Water Systems
(Note 1)
Miscellaneous 301.2.2, 301.3
CSA B137.1-2013 Polyethylene (PE) Pipe, Tubing, and Fittings for Cold-Water
Pressure Services
Piping, Plastic Table 604.1
CSA B137.5-2013 Crosslinked Polyethylene (PEX) Tubing Systems for
Pressure Applications
Piping, Plastic Table 604.1
CSA B137.6-2013 Chlorinated Polyvinyl chloride (CPVC) Pipe, Tubing, and
Fittings for Hot- and Cold-Water Distribution Systems
Piping, Plastic Table 604.1
CSA B137.9-2013 Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure-Pipe Systems
Piping, Plastic Table 604.1
CSA B137.10-2013 Cross linked Polyethylene/Aluminum/Crosslinked Polyethylene
(PEX-AL-PEX) Composite Pressure-Pipe Systems
Piping, Plastic Table 604.1
CSA B137.11-2013 Polypropylene (PP-R) Pipe and Fittings for Pressure Applications Piping, Plastic 605.11.1, Table 604.1
CSA B1B1.3-2011 Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory
Drainage Systems
Piping, Plastic 811.2
CSA B242-2005 (R2011)
Groove and Shoulder-Type Mechanical Pipe Couplings
Fittings 301.2.2, 301.3
CSA B356-2010 Water Pressure Reducing Valves for Domestic Water Supply
Systems
Valves 301.2.2, 301.3
CSA B481-2012 Grease Interceptors
DWV Components 1014.1
CSA G401-2007 (R2013)
Corrugated Steel Pipe Products Piping, Ferrous 301.2.2, 301.3
CSALC 1b-2011* Fuel Gas Piping Systems Using Corrugated Stainless Steel
Tubing (CSST) (same as CSA 6.26b)
Fuel Gas
1208.5.3.4
CSA LC 3-2000 (R2005)* Appliance Stands and Drain Pans Miscellaneous 301.2.2, 301.3
CSA LC 4a-2013* Pres-Connect Metallic Fittings for Use in Fuel Gas
Distribution Systems (same as CSA 6.32a)
Fuel Gas 1208.5.8.1, 1208.5.8.2
CSA Z21.10.1-2013* Gas Water Heaters - Volume I, Storage Water Heaters with
Input Ratings of 75 000 Btu Per Hour or Less (same as CSA
4.1)
Fuel Gas, Appliances Table 501.1(2)
CSA Z21.10.3-2013* Gas-Fired Water Heaters - Volume III, Storage Water Heaters
with Input Ratings Above 75 000 Btu Per Hour, Circulating
and Instantaneous (same as CSA 4.3)
Fuel Gas, Appliances Table 501.1(2),
Table L 603.3.2
CSA Z21.12b-1994
(R2010)*
Draft Hoods Fuel Gas, Appliances 301.2.2, 301.3
CSA Z21.13b-2013* Gas-Fired Low Pressure Steam and Hot Water Boilers (same
as CSA4.9)
Fuel Gas, Appliances 301.2.2, 301.3
CSA Z21.13b-2013* Manually Operated Gas Valves for Appliances, Appliance
Connector Valves, and Hose End Valves (same as CSA 9.1b)
Fuel Gas 301.2.2, 301.3
CSA Z21.22b-2001(R2008)* Relief Valves for Hot Water Supply Systems (same as CSA
4.4b
Valves 607.5, 608.7
CSA Z21.24a-2009(R2011)* Connectors for Gas Appliances (same as CSA 6.10a) Fuel Gas 1212.1(3), 1212.2
CSA Z21A0.1a-1997
(R2012*)
Gas-Fired, Heat Activated Air-Conditioning and Heat Pump
Appliances (same as CGA 2.91a)
Fuel Gas, Appliances 301.2.2, 301.3
CSA Z21.41-2011* Quick-Disconnect Devices for Use with Gas Fuel Appliances
(same as CSA 6.9)
Fuel Gas 1212.6
CSA Z21.47-2012* Gas-Fired Central Furnaces (same as CSA 2.3) Fuel Gas, Appliances 301.2.2, 301.3
CSA Z21.54b-2009* Gas Hose Connectors for Portable Outdoor Gas-Fired
Appliances (same as CSA 8.4b)
Fuel Gas 1212.3.2
CSAZ21.56-2013* Gas-fired Pool Heaters (same as CSA 4.7)
Fuel Gas, Swimming
Pools, Spas, and Hot
Tubs
301.2.2, 301.3
CSA Z21.69a-2012* Connectors for Movable Gas Appliances (same as CSA 6.16a)
Fuel Gas 1212.1.1
CSA Z21.75a-2009* Connectors for Outdoor Gas Appliances and Manufactured
Homes (same as CSA 6.27a)
Appliances 1212.1.1(4)
CSA Z21.80a-2012* Line Pressure Regulators (same as CSA 6.22a) Fuel Gas 1208.7.2, 1208.7.5(1)
CSA Z21.81a-2007
(R2010)*
Cylinder Connection Devices (same as CSA 6.25a) Fuel Gas 301.2.2, 301.3
CSA Z21.86-2008* Vented Gas-Fired Space Heating Appliances (same as CSA
2.32)
Fuel Gas Appliances
301.2.2, 301.3
CSA Z21.90b-2006
(R2011)*
Gas Convenience Outlets and Optional Enclosures (same as
CSA6.24b)
Fuel Gas 1212.7
CSA Z21.93-20 13* Excess Flow Valves for Natural and LP Gas with Pressures
up to 5 psig (same as CSA 6.30)
Fuel Gas 301.2.2, 301.3
CSA Z83.11 b-2009
(R2011)*
Gas Food Service Equipment (same as CSA 18b) Fuel Gas, Appliances 301.2.2, 301.3
CSA Z317.1-2009
Special Requirements for Plumbing Installations in Health
Care Facilities
Miscellaneous 301.2.2, 301.3
Energy Star-2007
(version 2.0)
Specification for Commercial Dishwashers Appliances L 403.1
Energy Star-2011
(version 6.0)
Specification for Clothes Washers
Appliances L 403.2
Energy Star-2012
(version 5.0)
Specification for Residential Dishwashers Appliances L 403.1
EPA WaterSense-2007 High-Efflciency Lavatory Faucet Specification
Fixtures L 402.5.1
EPA WaterSense-2009 Specification for Flushing Urinals
Fixtures L402.3, Table L402.1
EPA WaterSense-2011 Specification for Tank-Type Toilets
Fixtures L 402.2.1
Table L 402.1
IAPMO IGC 154-2013 Shower-and TUb/shower Enclosures and Shower Panels Fixtures 301.2.2, 301.3
IAPMO IGC 157-2013e1 Ball Valves
Valves 301.2.2, 301.3
IAPMO IGC 193-2010 Safety plates, Plate Straps, Notched Plates and Safety Collars
Miscellaneous
301.2.2, 301.3
IAPMO IGC 226-2006a Drinking Water Fountains With or Without Chiller or Heater
Fixtures 301.2.2, 301.3
IAPMO IGC 276-2011
Bundled Expanded Polystyrene Synthetic Aggregate Units
DWV Components
H 301.1(5)
IAPMO PS 23-2006a Dishwasher Drain Airgaps Backflow Protection 301.2.2, 301.3
IAPMO PS 25-2002 Metallic Fittings for Joining Polyethylene Pipe for Water
Service and Yard Piping
Joints 301.2.2, 301.3
IAPMO PS 34-2003 Encasement Sleeve for Potable Water Pipe and Tubing
Piping 301.2.2, 301.3
IAPMO PS 36-1990 Lead Free Sealing Compounds for Threaded Joints Joints 301.2.2, 301.3
IAPMO PS 37-1990 Black Plastic PVC or PE Pressure-SensItive Corrosion
Preventive Tape
Miscellaneous 301.2.2, 301.3
IAPMO PS 42-2013e1 Pipe Alignment and Secondary Secondary Support System
Miscellaneous 301.2.2, 301.3
IAPMO PS 50-2010 Flush Valves with Dual Flush Device For Water Closets or
Water Closet Tank with an Integral Flush Valves with a Dual
Flush Device
Fixtures 301.2.2, 301.3
IAPMO PS 51-2013 Expansion Joints for DWV Piping Systems Joints 301.2.2, 301.3
IAPMO PS 52-2009 Pump/Dose, Sumps and Sewage Ejector Tanks with or
without a Pump
DWV Components 301.2.2, 301.3
IAPMO PS 53-2013 Grooved Mechanical Couplings and Grooved Fittings Joints 301.2.2, 301.3
IAPMO PS 54-2011a
Metallic and Plastic Utility Boxes Miscellaneous 301.2.2, 301.3
lAPMO PS 57-2002 PVC Hydraulically Actuated Diaphragm Type Water Control
Valves
Valves 301.2.2, 301.3
IAPMO PS 59-2013
Wastewater Diverter Valves and Diversion Systems
DWV Components 301.2.2, 301.3
IAPMO PS 60-1996 Sewage Holding Tank Containing Sewage Ejector Pump for
Direct Mounted Water Closet
DWV Components 301.2.2, 301.3
IAPMO PS 63-2013 Plastic Leaching Chambers DWV Components H 301.1(5)
IAPMO PS 64-2012ae1 Roof Pipe Flashings Miscellaneous 301.2.2, 301.3
IAPMO PS 65-2002 Airgap Units for Water Conditioning Equipment Installation Baekflow Protection 611.2
IAPMO PS 66-2000 Dielectric Waterway Fittings Fittings 301.2.2, 301.3
IAPMO PS 67-2010 Early-Closure Replacement Flappers or Early-Closure
Replacement Flapper with Mechanical Assemblies
Fixtures 301.2.2, 301.3
IAPMO PS 69-2006 Bathwaste and Overflow Assemblies with Tub Filler Spout DWV Components 301.2.2, 301.3
IAPMO PS 72-2007e1 Valves with Atmospheric Vacuum Breakers Valves 301.2.2, 301.3
IAPMO PS 73-1993 Dental Vacuum Pumps
Miscellaneous 301.2.2, 301.3
lAPMO PS 76-2012a Trap Primers for Fill Valves and FIushometer Valves
DWV Components L 412.1
IAPMO PS 79-2005 Multiport Electronic Trap Primer DWV Components 301.2.2, 301.3
IAPMO PS 80-2008 Clarifiers DWV Components 301.2.2, 301.3
IAPMO PS 81-2006 Precast Concrete Seepage Pit Liners and Covers
DWV Components 301.2.2, 301.3
lAPMO PS 82-1995 Fiberglass (Glass Fiber Reinforced Thermosetting Resin)
Fittings
Fittings 301.2.2, 301.3
IAPMO PS 85-1995 Tools for Mechanically Formed Tee Connections in Copper
Tubing
Miscellaneous
301.2.2, 301.3
IAPMO PS 86-1995 Rainwater Diverter Valve for Non-Roofed Area Slabs DWV Components 301.2.2, 301.3
IAPMO PS 87-1995 Diverter and Shutoff Valves for Pool/spas Swimming Pools,
Spas, and Hot Tubs
301.2.2, 301.3
IAPMO PS 89-1995 Soaking and Hydrotherapy (Whirlpool) Bathtubs with
Hydraulic Seatlift
Fixtures 301.2.2, 301.3
IAPMO PS 90-2012e1 Elastomeric Test Caps, Cleanout Caps, and Combination Test
Caps/Shielded Couplings
DWV Components 301.2.2, 301.3
IAPMO PS 91-2005a Plastic Stabilizers for Use with Plastic Closet Bends DWV Components 301.2.2, 301.3
IAPMO PS 92-2013 Heat Exchangers and Indirect Water Heaters Miscellaneous L 606.1
IAPMO PS 94-2012 Insulated Protectors for P-Traps, Supply Stops and Risers Miscellaneous 301.2.2, 301.3
IAPMO PS 94-2001 Drain, Waste, and Vent Hangers and Plastic Pipe Support
Hooks
DWV Components 301.2.2, 301.3
IAPMO PS 96-2002 Passive Direct Solar Water Heaters Appliances 301.2.2, 301.3
IAPMO PS 98-1996 Prefabricated Fiberglass Church Baptisteries Fixtures 301.2.2, 301.3
IAPMO PS 100-1996 Porous Filter Protector for Sub-Drain Weep Holes DWV Components
301.2.2, 301.3
IAPMO PS 101-1997 Porous Filter Protector for Sub-Drain Weep Holes Valves 301.2.2, 301.3
IAPMO PS 104-1997 Pressure Relief Connection for Dispensing Equipment Valves 301.2.2, 301.3
IAPMO PS 105-1997 Polyethylene Distribution Boxes DWV Components 301.2.2, 301.3
IAPMO PS 106-2013b Tileable Shower Receptors and Shower Kits
Fixtures 301.2.2, 301.3
IAPMO PS 107-1998 Aramid Reinforced Rubber Hose for Use in Non-Potable
Water Radiant Heating and Snowmelting
Miscellaneous 301.2.2, 301.3
IAPMO PS 108-1998 Restaurant Fire Suppression Systems Miscellaneous 301.2.2, 301.3
IAPMO PS 110-2006a PVC Cold Water Compression Fittings Fittings 301.2.2, 301.3
IAPMO PS 111-1999
PVC Cold Water Gripper Fittings Fittings 301.2.2, 301.3
IAPMO PS 112-1999 PVC Plastic Valves for Cold Water Distribution Systems
Outside a Building and CPVC Plastic Valves for Hot and
Cold Water Distribution Systems
Valves 301.2.2, 301.3
IAPMO PS 113-2010 Hydraulically Powered Household Food Waste Disposers
Appliances 301.2.2, 301.3
IAPMO PS 114-1999e1 Remote Floor Box Industrial Water Supply, Air Supply,
Drainage
Miscellaneous 301.2.2, 301.3
IAPMO PS 115-2007 Hot Water On-Demand or Automatic Activated Hot Water
Pumping Systems
Miscellaneous 301.2.2, 301.3
IAPMO PS 116-1999 Hot Water Circulating Devices Which Do Not Use a Pump Miscellaneous 301.2.2, 301.3
IAPMO PS 117-2012ae1 Press and Nail Connections Fittings 301.2.2, 301.3
IAPMO PS 119-2012ae1 Water-Powered Sump Pumps Miscellaneous 301.2.2, 301.3
IAPMO Z124,5-2013e1* Plastic Toilet Seats
Fixtures 411.3
IAPMO Z124,7-2013* Prefabricated Plastic Spa Shells
Fixtures, Swimming
Pools, Spas, and Hot
Tubs
301.2.2, 301.3
IAPMO Z124.8-2013e1 Plastic Liners for Bathtubs and Shower Receptors
Fixtures 301.2.2, 301.3
IAPMO Z1000-2013* Prefabricated Septic Tanks
DWV Components 301.2.2, 301.3
IAPMO Z1001-2013* Prefabricated Gravity Grease Interceptors DWV Components 1014.3.4
IAPMO Z1001-2013e1* Flexible PVC Hoses and Tubing for Pools, Hot Tubs, Spas,
and Jetted Bathtubs
Fixtures, Swimming
Pools, Spas, and Hot
Tubs
409.6.1
IAPMO Z1088-2013* Pre--Pressurized Water Expansion Tanks Miscellaneous 301.2.2, 301.3
ICC A117.1-2009*
Accessible and Usable Buildings and Facilities
Miscellaneous 403.2, 408.6
ICC Z358.1-2009* Emergency Eyewash and Shower Equipment
Miscellaneous 416.1, 416.2
ISO/IEC Guide 65-1996 General Requirements for Bodies Operating Product Certification
Systems
Certification 301.2.2, 301.3
MSS SP-6-2012 Finishes For Contact Faces of Pipe Flanges and Connecting-End Flanges of Valves and Fittings
Fuel Gas
1208.5.10
MSS SP-25-2013* Marking System for Valves, Fittings, Flanges, and Unions
Miscellaneous 301.2.2, 301.3
MSS SP-42-2013 Corrosion-Resistant Gate, Globe, Angle, and Check Valves
with Flanged and Butt Weld Ends (Classes 150, 300, & 600)
Piping, Ferrous 301.2.2, 301.3
MSS SP-44-2010
Steel Pipeline Flanges
Fittings 301.2.2, 301.3
MSS SP-58-2009* Pipe Hangers and Supports - Materials, Design, Manufacture
Selection, Application, and Installation
Miscellaneous 1210.2.4, 1310.5.1
MSS SP-67-2011* Butterfly Valves
Valves 606.1
MSS SP-70-2011* Gray from Gate Valves, Flanged and Threaded Ends
Valves 606.1
MSS SP-71-2011* Gray Iron Swing Check Valves, Flanged and Threaded Ends Valves 606.1
MSS SP-72-2010a Ball Valves with Flanged or butt-Welding Ends for General
Service
Valves 606.1
MSS SP-78-2011 Gray Iron Plug Valves, Flanged and Threaded Ends Valves 606.1
MSS SP-80-2013 Bronze Gate, Globe, Angle, and Check Valves Valves 606.1
MSS SP-83-2006 Class 3000 Steel Pipe Unions Socket Welding and Threaded
Joints 301.2.2, 301.3
MSS SP-104-2012 Wrought Copper Solder-Joint Pressure Fittings
Fittings 301.2.2, 301.3
MSS SP-106-2012 Cast Copper Allow Flanges and Flanged Fittings: Class 125,
150, and 300
Fittings 301.2.2, 301.3
MSS SP-109-2012 Weld-Fabricated Copper Solder-Joint Pressure Fittings
Fittings 301.2.2, 301.3
MSS SP-110-2010 Ball Valves Threaded, Socket-Welding, Solder-Welding,Solder Joint,
Grooved and Flared Ends
Valves 606.1
MSS SP-122-2012 Plastic Industrial Ball Valves Valves 606.1
MSS SP-123-2013 Non-Ferrous Threaded and Solder-Joint Unions for Use with
Copper Water Tube
Joints 301.2.2, 301.3
NFPA 13D-2013* Installation of Sprinkler Systems in One- and Two-Family
Dwellings and Manufactured Homes
Miscellaneous 612.1, 612.5.3.1
NFPA 13R-2013* Installation of Sprinkler Systems in Low-Rise Residential
Occupancies
Miscellaneous 301.2.2, 301.3
NFPA 30A-2012
Motor Fuel Dispensing Facilities and Repair Garages
Miscellaneous 507.14.2
NFPA 31-2011* Installation of Oil-Burning Equipment Fuel Gas, Appliances 505.3, 1201.1, E 401.1,
E412.1, E413.6,
E413.6.1, E414.1,
E415.2, E415.3
NFPA 51-2013* Design and Installation of Oxygen-Fuel Gas Systems for
Welding, Cutting, and Allied Processes
Fuel Gas 507.9
NFPA 54/7223.1-2012* National Fuel Gas Code Fuel Gas 121014, E 401 . 1,
E 408.1, E 414.1,
E 415.1
NFPA 58-2014* Liquefied Petroleum Gas Code Fuel Gas 1208.5.4.2.3,
1208.5.9.4, 1210.5(6),
1212.10, E 401.1,
E 401.2, E 406.1,
E 411.1 , E 414.1,
E 415.1
NFPA 70-2014* National Electrical Code Miscellaneous 1211.6,1310.4.1,
1318.1(11), F 701.1
NFPA 80-2013* Fire Doors and Other Opening Protectives Miscellaneous 301.2.2, 301.3
NFPA 85-2011* Boiler and Combustion Systems Hazards Code Appliances 301.2.2, 301.3
NFPA 88A-2011* Parking Structures Miscellaneous 507.14.1
NFPA 99-2012* HeaIth Care Facilities Code Piping 1301.3,1318.1(9)
NFPA 130-2014* Fixed Guideway Transit and Passenger Rail Systems Miscellaneous 301.2.2, 301.3
NFPA 211-2013* Chimneys, Fireplaces, Vents, and Solid Fuel-Burning
Appliances
Fuel Gas, Appliances 509.5.2, 509.5.3,
509.5.6.1, 509.5.6.3
NFPA-220-2012* Types of Building Construction Miscellaneous 301.2.2, 301.3
NFPA 409-2011* Aircraft Hangars Miscellaneous 507.15
NFPA 501A-2013* Fire Safety Criteria for Manufactured Home Installations,
Sites, and Communities
Miscellaneous 301.2.2, 301.3
NFPA 502-2014* Road Tunnels, Bridges, and Other Limited Access Highways Miscellaneous 301.2.2, 301.3
NFPA 780-2014* Installation of Lightning Protection Systems Fuel Gas 1211.4
NFPA 1981-2013* Open-Circuit Self-Contained Breathing Apparatus (SCBA)
for Emergency Services
Miscellaneous 301.2.2, 301.3
NFPA 1989-2013* Breathing Air Quality for Emergency Services Respiratory
Protection
Miscellaneous F 1201.7
NFPA 5000-2012* Building Construction and Safety Code Miscellaneous 301.2.2, 301.3
NSF 2-2012* Food Equipment Appliances 301.2.2, 301.3
NSF 3-2010* Commercial Warewashing Equipment Appliances 414.1
NSF 4-2009* Commercial Cooking, Rethermalization, and Powered Hot
Food Holding and Transport Equipment
Appliances 301.2.2, 301.3
NSF 5-2012* Water Heaters, Hot Water Supply Boilers, and Heat Recovery
Equipment
Appliances 301.2.2, 301.3
NSF 12-2012* Automatic Ice Making Equipment
Appliances 301.2.2, 301.3
NSF 14-2012* Plastics Piping System Components and Related Materials Piping, Plastic 301.2.3, 604.1, 611.3
NSF 18-2012* Manual Food and Beverage Dispensing Equipment Appliances 301.2.2, 301.3
NSF 29-2009* Detergent and Chemical Feeders for Commercial Spray-Type
Dishwashing Machines
Appliances 301.2.2, 301.3
NSF 40-2013* Residential Wastewater Treatment Systems DWV Components 301.2.2, 301.3
NSF 41-2011* Non-Liquid Saturated Treatment Systems DWV Components 301.2.2, 301.3
NSF 42-2013* Drinking Water Treatment Units - Aesthetic Effects Appliances 611.1, 611.3
NSF 44-2013* Residential Cation Exchange Water Softeners Appliances 611.1, 611.3, L 410.1
NSF 46-2012* Evaluation of Components and Devices Used in wastewater
Treatment Systems
DWV Components 301.2.2, 301.3
NSF 53-2013* Drinking Water Treatment units - Health Effects
Appliances 611.1, 611.3,
K 104.2.1, LS04.2.1
NSF 55-2013* Ultraviolet Microbiological Water Treatment Systems Appliances 611.1, 611.3
NSF 58-2013* Reverse Osmosis Drinking Water Treatment Systems Appliances 611.1, 611.2, 611.3,
L 410.3
NSF 61-2012* Drinking Water System Components - Health Effects Water Supply Components 415.1, 417.1, 604.1,
604.9, 606.1, 607.2,
608.2
NSF 62-2013* Drinking Water Distillation Systems Appliances 611.1, 61 .3
NSF 169-2012* Special Purpose Food Equipment and Devices Appliances 301.2.2, 301.3
NSF 350-2012* Onsite Residential and Commercial Water Reuse Treatment
Systems
Note: NSF/ANSI 350. amended sections follow:
5.6 Electrical Components. Electrical components ... The California
Electrical Code shall be followed for all electrical components. system
installation, and system operation
Miscellaneous
1501.7, 1504.10.2
NSF 359-2011* Valves for Crosslinked Polyethylene (PEX) Water
Distribution Tubing Systems
Valves 606.1
PDI G-101-2012 Testing and Rating Procedure for Hydro Mechanical Grease
Interceptors with Appendix of Installation and Maintenance
DWV Components 1014.1
PDI G-102-2010 Testing and Certification for Grease Interceptors with FOG
Sensing and Alarm Devices
Certification 1014.1
PDI-WH 201-1010 Water Hammer Arresters Water Supply Components 609.10
PSAI Z4.1-2005* For Sanitation - In Places of Employment - Minimum
Requirements
Miscellaneous 301.2.2, 301.3
SAE J512-1997 Automotive tube Fittings
Fittings 301.2.2, 301.3
SAE 11670-2008 Type "F" Clamps for Plumbing Applications Joints 301.2.2, 301.3
TCNA A118.10-2011* Load Bearing, Bonded, Waterproof Membranes for Thin-Set
Ceramic Tile and Dimension Stone Installation
Miscellaneous 301.2.2, 301.3
TCNAA137.1-2012* Specifications for Ceramic Tile Miscellaneous 301.2.2, 301.3
UL 17-2008 Vent or Chimney Connector Dampers for Oil-Fired
Appliances (with revisions through September 25,2013)
Vent Dampers 509.13.1
UL 70-2001 Septic Tanks, Bituminous-Coated Metal
DWV Components H 501.14(1)
UL 80-2007* Steel Tanks for Oil-Burner Fuels and Other Combustible
Liquids (with revisions through January 16, 2014)
Fuel Gas E 413.6.2
UL 103-2010* Factory-Built Chimneys for Residential Type and Building
Heating Appliances (with revisions through July 27, 2012)
Fuel Gas Appliances 509.5.1.1, 509.5.1.2
UL 125-2009* Flow Control Valves for Anhydrous Ammonia and LP-Gas
(with revisions through November 10, 20 11)
Fuel Gas 301.2.2, 301.3
UL 132-2007* Safety Relief Valves for Anhydrous Ammonia and LP-Gas
(with revisions through July 23,2010)
Fuel Gas 301.2.2, 301.3
UL 144-2012* LP-Gas Regulators Fuel Gas 301.2.2, 301.3
UL 174-2004* Household Electric Storage Tank Water Heater (with revisions
through September 21, 2012)
Appliances
Table 501.1(2)
UL 252-2010* Compressed Gas Regulators (with revisions through
September 4,2013)
Fuel Gas 301.2.2, 301.3
UL 263-2011* Fire Tests of Building Construction and Materials Miscellaneous 1404.3, 1405.3
UL 296-2003*
Oil Burners (with revisions through September 17, 2013)
Fuel Gas, Appliances 301.2.2, 301.3
UL 343-2008 Pumps for Oil-Burning Appliances (with revisions through
June 12,2013)
Fuel Gas, Appliances 301.2.2, 301.3
UL 378-2006 Draft Equipment (with revisions through September 17,
2013)
Fuel Gas, Appliances 509.13.1
UL 399-2008* Drinking Water Coolers (with revisions through October 18,
2013)
Appliances 415.1
UL 404-2010* Gauges, Indicating Pressure, for Compressed Gas Service
Fuel Gas
301.2.2, 301.3
UL 429-2013 Electrically Operated Valves Valves 301.2.2, 301.3
UL 430-2009* Waste Disposers (with revisions through October 3,2013) Appliances 419.1
UL 441-2010* Gas Vents (with revisions through May 18,2010) Fuel Gas 509.1
UL 443-2006* Steel Auxiliary Tanks for Oil-Burner Fuel (with revisions
through March 8, 2013)
Fuel Gas 301.2.2, 301.3
UL 499-2005* Electric Heating Appliances (with revisions through February
11, 2013)
Appliances 301.2.2, 301.3
UL 536-1997 Flexible Metallic Hose (with revisions through June 9,2003)
Fuel Gas 301.2.2, 301.3
UL 563-2009* Ice Makers (with revisions through November 29,2013) Appliances 301.2.2, 301.3
UL 565-2013 Liquid-Level Gauges for Anhydrous Ammonia and LP-Gas
Fuel Gas 301.2.2, 301.3
UL 569-2013* Pigtails and Flexible Hose Connectors for LP-Gas Fuel Gas 301.2.2, 301.3
UL 641-2010* Type L Low-Temperature Venting Systems (with revisions
through June 12, 2013)
Fuel Gas 509.1
UL 651-2011* Schedule 40, 80, Type EB and A Rigid PVC Conduit and Fittings (with revisions through March 30, 2012)
Piping, Plastic
1208.5.4.1
UL 723-2008* Test for Surface Burning Characteristics of Building Materials
(with revisions through August 12, 2013)
Miscellaneous 701.2(2), 903.1 (2),
1101.4
UL 726-1995 Oil-Fired Boiler Assemblies (with revisions through October
9,2013)
Fuel Gas, Appliances 301.2.2, 301.3
UL 732-1995* Oil-Fired Storage Tank Water Heaters (with revisions through
October 9, 2013)
Fuel Gas, Appliances Table 501.1(2)
UL 749-2013* Household Dishwashers (with revisions through May 24, 2013) Appliances 414.1
UL 778-2010* Motor-Operated Water Pumps (with revisions through May
25,2012)
Appliances 1101.14
UL 834-2004*
Heating Water Supply, and Power Boilers-Electric (with
revisions through December 9, 2013)
Appliances 301.2.2, 301.3
UL 921-2006* Commercial Dishwashers (with revisions through July 6,
2012)
Appliances 414.1
UL 959-2010* Medium Heat Appliance Factory-Built Chimneys Fuel Gas, Appliances 509.5.1.2
UL 1081-2008* Swimming Pool Pumps, Filters, and Chlorinators (with revisions
through May 31, 2013)
Swimming Pools,
Spas, and Hot Tubs
301.2.2, 301.3
UL 1206-2003* Electric Commercial Clothes-Washing Equipment (with revisions through November 30, 2012) Appliances 301.2.2, 301.3
UL 1261-2001* Electric Water Heaters for Pools and Tubs (with revisions
through July 31,2012)
Appliances, Swimming
Pools, Spas, and
Hot Tubs
301.2.2, 301.3
UL 1331-2005 Station Inlets and Outlets (with revisions through August 18,
2010)
Medical Gas 301.2.2, 301.3
UL 1453-2004* Electric Booster and Commercial Storage Tank Water
Appliances Heaters (with revisions through July 15,2011)
Appliances Table 501.1 (2)
UL 1469-2006 Strength of Body and Hydraulic Pressure Loss Testing of
Backflow Special Check Valves (with revisions through
March 19,2010)
Backflow Protection 301.2.2, 301.3
UL 1479-2003* Fire Tests of Through-Penetration Firestops (with revisions
through October 19, 2012)
Miscellaneous 208.0,222.0, 1404.3,
1405.3
UL 1795-2009 Hydromassage Bathtubs (with revisions through January 13, 2012) Fixtures 301.2.2, 301.3
UL 1951-2011* Electric Plumbing Accessories Miscellaneous 301.2.2, 301.3
UL 2157-1997* Electric Clothes Washing Machines and Extractors (with
revisions through February 16, 20 10)
Appliances 301.2.2, 301.3
UL 2523-2009* Solid Fuel-Fired Hydronic Heating Appliances, Water
Heaters, and Boilers (with revisions through February 8,
2013)
Fuel Gas, Appliances Table 501.1(2)
WQA S-300-2000
Point-of-Use Low Pressure Reverse Osmosis Drinking Water
Systems
Appliances 301.2.2, 301.3
*ANSI designated as an American National Standard.
Italic/Bold referenced standards indicate where such standards are located in the narrative of the code.

Notes:

1   Although this standard is referenced in Table 1701.1, some of the pipe, tubing, fittings, valves, or fixtures included in the standard are not acceptable for use under the provisions of the Uniform Plumbing Code.
2   See Section 605.1.4 and Section 705.3.3 for restrictions.
3   Alloy C85200 for cleanout plugs.
4   Limited to domestic sewage
5   Type II only.
6   ASSE 1066 is not intended to limit the maximum outlet temperature at point of use.
7   See Section 314.0 for trenching, excavation, and backfilling requirements where installing building drains and sewers. Engineers shall be permitted to consult ASTM D2321, for thermoplastic pipe, where preparing construction documents for sewer mains or specific projects.


ABBREVIATIONS IN TABLE 1701.1
AHAM Association of Home Appliance Manufacturers, 1111 19th Street, NW, Suite 402, Washington, DC 20036.
ANSI American National Standards Institute, Inc., 25 W. 43rd Street, 4th Floor, New York, NY 10036.
APSP Association of Pool and Spa Professionals, 2111 Eisenhower Avenue, Suite 500, Alexandria, VA 22314-4679.
ASCE American Society of Civil Engineers, 1801 Alexander Bell Drive, Reston, VA 20191-4400.
ASHRAE American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc. , 1791 Tullie Circle,
NE,Atlanta,GA 30329-2305.
ASME American Society of Mechanical Engineering, Two Park Avenue, New York, NY 10016-5990
ASPE American Society of Plumbing Engineers, 6400 Schafer Court, Suite 350, Rosemont, IL 60018.
ASSE American Society of Sanitary Engineering, 18927 Hickory Creek Drive, Suite 220, Mokena, IL 60448.
ASTM ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959
AWS American Welding Society, 8669 NW 36 Street, #130 Miami, FL 33166-6672.
AWWA American Water Works Association, 6666 W Quincy Avenue, Denver, CO 80235.
CGA Compressed Gas Association, 14501 George Carter Way, Suite 103, Chantilly, VA 20151.
CISPI Cast-Iron Soil Pipe Institute, 2401 Fieldcrest Drive, Mundelein, IL 60060.
CSA Canadian Standards Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada, L4W 5N6.
e1 An editorial change since the last revision or reapproval.
ENERGY STAR 1200 Pennsylvania Avenue, N.W, Washington, D.C. 20460.
EPA
WATERSENSE U.S. Environmental Protection Agency, Office of Wastewater Management (4204M), 1200 Pennsylvania
Avenue, N.W, Washington, D.C. 20460.
IAPMO International Association of Plumbing and Mechanical Officials, 5001 E. Philadelphia Street, Ontario, CA
91761.
ICC International Code Council, 500 New Jersey Avenue, NW, 6th Floor, Washington, DC 20001.
ISEA International Safety Equipment Association, 1901 N. Moore Street, Arlington, VA 22209-1762.
ISO International Organization for Standardization, 1 ch. de la Voie-Creuse, Casa Postale 56, CH-1211 Geneva
20, Switzerland
MSS Manufacturers Standardization Society of the Valve and Fittings Industry, 127 Park Street, NE, Vienna, VA
22180.
NFPA National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471.
NSF NSF International, 789 N. Dixboro Road, Ann Arbor, MI 48105.
PDI Plumbing and Drainage Institute, 800 Turnpike Street, Suite 300, North Andover, MA 01845.
PSAI Portable Sanitation Association International, 2626 E 82nd Street, Suite 175, Bloomington, MN 55425.
SAE Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096.
TCNA Tile Council of North America, Inc. 100 Clemson Research Blvd., Anderson, SC 29625.
UL Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062.
WQA Water Quality Association, 4151 Naperville Road, Lisle, IL 60532-3696.