Heads up: There are no amended sections in this chapter.
CALIFORNIA MECHANICAL CODE - MATRIX ADOPTION TABLE
CHAPTER 17 - REFERENCED STANDARDS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
Adopting agency BSC BSC-CG SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
1 2 1-AC AC SS SS/CC 1 1R 2 3 4 5
Adopt entire chapter X X X
Adopt entire chapter as
amended (amended
sections listed below)
X X X X X X X X X
Adopt only those sections
that are listed below
Chapter / Section
Table 1701.1 X X X X X X X X X X
This state agency does not adopt sections identified with the following symbol:
The Office of the State Fire Marshal's adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.0.
The standards listed in Table 1701.1 are referenced in various sections of this code and shall be considered part of the requirements of this document. The standards are listed herein by the standard number and effective date, the title, application and the section(s) of this code that reference the standard. The application of the referenced standard(s) shall be as specified in Section 302.1.2.

     The promulgating agency acronym referred to in Table 1701.1 are defined in a list found at the end of the table.

TABLE 1701.1
REFERENCED STANDARDS
STANDARD NUMBER STANDARD TITLE APPLICATION REFERENCED SECTION
AABC-2016 Total System Balance, 7th Edition Balancing 314.1(1)
ACCA Manual B-2009 Balancing and Testing Air and Hydronic Systems Balancing 314.1(1)
ACCA Manual D-2016 Residential Duct Systems Ducts, Balancing 601.2
ACCA4 QM-2013 Maintenance of Residential HVAC Systems HVAC Systems 102.3.2
ARRI 700-2016a Specifications for Refrigerants Refrigerants 1104.7, 1104.7.3
AMCA 540-2013 Louvers Impacted by Wind Borne Debris Louvers 315.1.2
AMCA 550-2015 Test Method for High Velocity Wind Driven Rain Resistance Louvers Louvers 315.1.1
ASHRAE 15-2016 Safety Standard for Refrigeration Systems Refrigeration Systems 1102.1, 1106.1, Table 1113.5
ASHRAE 34-2016 Designation and Safety Classification of Refrigerants Refrigeration Classifications 1102.3, 1103.1, Table 1102.3, Table 1106.2.5.2
ASHRAE 62.1-2016 Ventilation for Acceptable Indoor Air Quality Indoor Air Quality Ventilation 402.4.1
ASHRAE 62.2-2016 Ventilation and Acceptable Indoor Air Quality in Residential Buildings Ventilation 402.1.2
ASHRAE 111-2008 Measurement, Testing, Adjusting, and Balancing of Building HVAC Systems Balancing 314.1(3)
ASHRAE 129-1997 (R2002) Measuring Air-Change Effectiveness Air Change Effectiveness Table 403.2.2
ASHRAE 154-2016 Ventilation for Commercial Cooking Operations Commercial Kitchens 510.5.6
ASHRAE 170-2013 Ventilation of Health Care Facilities Ventilation 402.1.3
ASHRAE/ACCA 180-2012 Inspection and Maintenance of Commercial Building HYAC Systems Maintenance 102.3.1, 1013.3
ASHRAE Handbook-2013 Fundamentals Climatic Conditions Figure 803.1.2(6)
ASME B1.20.1-2013 Pipe Threads, General Purpose (Inch) Joints 1211.2(3), 1211.4(7), 1211.12(3), 1211.13(2), 1308.5.7
ASME B16.1-2015 Gray Iron Pipe Flanges and Flanged Fittings: Classes 25, 125, and 250 Fittings 1308.5.10
ASME B16.3-2011 Malleable Iron Threaded Fittings: Classes 150 and 300 Fittings Table 1210.1
ASME B16.5-2013 Pipe Flanges and Flanged Fittings: NPS 1/2 through NPS 24 Metric/Inch Fittings Table 1210.11308.5.10.1
ASME B16.9-2012 Factory-Made Wrought Buttwelding Fittings Fittings Table 1210.1
ASME B16.11-2011 Forged Fittings, Socket-Welding and Threaded Fittings Table 1210.1
ASME B16.15-2013 Cast Copper Alloy Threaded Fittings: Classes 125 and 250 Fittings Table 1210.1
ASME B16.18-2012 Cast Copper Alloy Solder Joint Pressure Fittings Fittings Table 1210.1
ASME B16.20-2012 Metallic Gaskets for Pipe Flanges: Ring-Joint, Spiral-Wound, and Jacketed Joints 1308.5.11.2
ASME B16.21-2011 Nonmetallic Flat Gaskets for Pipe Flanges Fuel Gas Piping 1308.5.11.3
ASME B16.22-2013 Wrought Copper and Copper Alloy Solder-Joint Pressure Fittings Fittings Table 1210.1
ASME B16.23-2011 Cast Copper Alloy Solder Joint Drainage Fittings: DWV Fittings Table 1210.1
ASME B16.24-2011 Cast Copper Alloy Pipe Flanges and Flanged Fittings: Classes 150, 300, 600, 900, 1500, and 2500 Fittings Table 1210.11308.5.10.2
ASME B16.26-2013 Cast Copper Alloy Fittings for Flared Copper Tubes Fittings Table 1210.1
ASME B16.29-2012 Wrought Copper and Wrought Copper Alloy Solder-Joint Drainage Fittings - DWV Fittings Table 1210.1
ASME B16.42-2011 Ductile Iron Pipe Flanges and Flanged Fittings Fuel Gas Piping 1308.5.10.3
ASME B16.47-2011 Large Diameter Steel Flanges Fuel Gas Piping 1308.5.10.1
ASME B16.51-2013 Copper and Copper Alloy Press-Connect Pressure Fittings Fittings Table 1210.1
ASME B31.5-2016 Refrigeration Piping and Heat Transfer Components Refrigeration Piping 1109.1.1, 1109.1.3
ASME B36.10M-2015 Welded and Seamless Wrought Steel Pipe Fuel Gas Piping 1308.5.2.1(1)
ASME BPVC Section 1-2015 Rules for Construction of Power Boilers Boilers 1002.1(1), Table 1003.2.1
ASME BPVC Section IV-2015 Rules for Construction of Heating Boilers Boilers 1002.1(2)
ASME BPVC Section VIII-2015 Rules for Construction of Pressure Vessels Division 1 Pressure Vessels 1002.1, 1004.3, 1112.10.11112.13, 1113.1, 1115.41115.4.1, 1117.1(2), 1117.1(3), 1117.2, 1209.4
ASME CSD-1-2015 Controls and Safety Devices for Automatically Fired Boilers Boilers 1003.2.1
ASSE 1013-2011 Reduced Pressure Principle Backflow Preventers and Reduced Pressure Principle Fire Protection Backflow Preventers Backflow Protection 1202.2
ASSE 1017-2009 Temperature Actuated Mixing Valves for Hot Water Distribution Systems Valves 1207.3.1
ASSE 1061-2015 Push-Fit Fittings Fittings 1211.2(1), 1211.4(5), Table 1210.1
ASTM A53/A53M-2012 Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless Piping 1308.5.2.1 (2), Table 1210.1
ASTM A106/A106M2-015 Seamless Carbon Steel Pipe for High-Temperature Service Piping 1308.5.2.1 (3), Table 1210.1
ASTM A126-2004 (R2014) Gray Iron Castings for Valves, Flanges, and Pipe Fittings Piping Table 1210.1
ASTM A254/A254M-2012 Copper-Brazed Steel Tubing Piping 1308.5.3.1, Table 1210.1
ASTM A420/A420M-2016 Piping Fittings of Wrought Carbon Steel and Alloy Steel for Low-Temperature Service  Fittings Table 1210.1
ASTM B32-2008 (R2014) Solder Metal Joints 1211.4(6)
ASTM B42-2015a Seamless Copper Pipe, Standard Sizes Piping Table 1210.1
ASTM B43-2015 Seamless Red Brass Pipe, Standard Sizes Piping Table 1210.1
ASTM B75/B75M-2011 Seamless Copper Tube Piping Table 1210.1
ASTM B88-2016 Seamless Copper Water Tube Piping 1308.5.3.2, Table 1210.1
ASTM B135-2010 Seamless Brass Tube Piping Table 1210.1
ASTM B210-2012 Aluminum and Aluminum-Alloy Drawn Seamless Tubes Piping 1308.5.3.3
ASTM B241/B241M-2016 Aluminum and Aluminum-Alloy Seamless Pipe and Seamless Extruded Tube Piping 1308.5.2.3, 1308.5.3.3
ASTM B251-2010 General Requirements for Wrought Seamless Copper and Copper-Alloy Tube Piping Table 1210.1
ASTM B280-2016 Seamless Copper Tube for Air Conditioning and Refrigeration Field Service Piping 1109.1.2, 1308.5.3.2
ASTM B302-2012 Threadless Copper Pipe, Standard Sizes Piping Table 1210.1
ASTM B447-2012a Welded Copper Tube Piping Table 1210.1
ASTM B813-2016 Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube Joints 1211.4(6)
ASTM B828-2016 Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings Joints 1211.4(6)
ASTM B1003-2016 Seamless Copper Tube for Linesets Piping 1109.1.2
ASTM C315-2007 (R2016) Clay Flue Liners and Chimney Pots Venting Systems 803.1.11.1
ASTM C411-2011 Hot-Surface Performance of High-Temperature Thermal lnsulation Duct Coverings and Linings 604.1.2
ASTM D1693-2015 Environmental Stress-Cracking of Ethylene Plastics Piping Table 1210.1
ASTM D1785-2015 Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80, and 120 Piping Table 1210.1
ASTM D2241-2015 Poly (Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series) Piping Table 1210.1
ASTM D2464-2015 Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 Fittings Table 1210.1
ASTM D2466-2015 Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 Fittings Table 1210.1
ASTM D2467-2015 Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 Fittings Table 1210.1
ASTM D2513-2014e1 Polyethylene (PE) Gas Pressure Pipe, Tubing, and Fittings Piping 1308.5.4, 1308.5.4.2.21308.5.9.2, 1310.1.7.1(1), Table 1210.1
ASTM D2564-2012 Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems Joints 1211.12(2)
ASTM D2609-2015 Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe Fittings Table 1210.1
ASTM D2683-2014 Socket-Type Polyethylene Fittings for Outside Diameter-Controlled Polyethylene Pipe and Tubing Fittings Table 1210.1
ASTM D2737-2012a Polyethylene (PE) Plastic Tubing Piping, Plastic Table 1210.1
ASTM D2846/D2846M-2014 Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot-and Cold-Water Distribution Systems Piping 1211.2(2), 1211.3(2), Table 1210.1
ASTM D3035-2015 Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter Piping Table 1210.1
ASTM D3139-1998 (R2011) Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals Joints 1211.12(1)
ASTM D3261-2016 Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing Fittings Table 1210.1
ASTM D3350-2014 Polyethylene Plastics Pipe and Fittings Materials Piping, Fittings Table 1210.1
ASTM E84-2016 Surface Burning Characteristics of Building Materials Miscellaneous 508.3.4, 602.2, 604.1.21201.2
ASTM E814-2013a Fire Tests of Penetration Firestop Systems Miscellaneous 507.4.4, 507.4.5
ASTM E2231-2015 Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surface Burning Characteristics Insulation of Ducts 604.1.2
ASTM E2336-2016 Fire Resistive Grease Duct Enclosure Systems Grease Ducts 507.4.2.2, 507.4.5
ASTM F437-2015 Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 Fittings Table 1210.1
ASTM F438-2015 Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40 Fittings Table 1210.1
ASTM F439-2013 Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 Fittings Table 1210.1, 1211.2(2)
ASTM F441/F441M-2015 Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80 Piping Table 1210.1
ASTM F442/442M-2013e1 Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR) Piping Table 1210.1, 1211.2(2)
ASTM F493-2014 Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings Joints 1211.2(2), 1211.3(2)
ASTM F656-2015 Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings Joints 1211.2(2), 1211.3(2), 1211.12(2)
ASTM F714-2013 Polyethylene (PE) Plastic Pipe (DR-PR) Based on Outside Diameter Piping, Plastic Table 1210.1
ASTM F876-2015a Crosslinked Polyethylene (PEX) Tubing Piping 1211.5, Table 1210.1
ASTM F877-2011a Crosslinked Polyethylene (PEX) Hot-and Cold-Water Distribution Systems Piping Table 1210.1
ASTM F1055-2016a Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene (PEX) Pipe and Tubing Fittings Table 1210.1
ASTM F1281-2011 Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Pressure Pipe Piping Table 1210.1
ASTM F1282-2010 Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe Piping Table 1210.1
ASTM F1807-2015 Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing Fittings Table 1210.1
ASTM F1960-2015 Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing Fittings Table 1210.1
ASTM F1961-2009 Metal Mechanical Cold Flare Compression Fittings with Disc Spring for Crosslinked Polyethylene (PEX) Tubing Fittings Table 1210.1
ASTM F1970-2012el Special Engineered Fittings, Appurtenances or Valves for Use in Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Systems Piping Table 1210.1
ASTM F1973-2013el Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA 11) and Polyamide 12 (PA12) Fuel Gas Distribution Systems Fuel Gas 1310.1.7.1(2)
ASTM F1974-2009 (R2015) Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe Fittings 1211.6(1), 1211.9(1), Table 1210.1
ASTM F2080-2016 Cold-Expansion Fittings with Metal Compression-Sleeves for Crosslinked Polyethylene (PEX) Pipe and SDR9 Polyethylene of Raised Temperature (PE-RT) Pipe Fittings Table 1210.1
ASTM F2098-2015 Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert Fittings Joints Table 1210.1
ASTM F2159-2014 Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing Fittings Table 1210.1
ASTM F2262-2009 Crosslinked  Polyethylene/Aluminum/Crosslinked Polyethylene Tubing OD Controlled SDR9 Piping, Plastic Table 1210.1
ASTM F2389-2015 Pressure-Rated Polypropylene (PP) Piping Systems Piping  1211.11(1), Table 1210.1
ASTM F2434-2014 Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Tubing Fittings 1211.6(1), Table 1210.1
ASTM F2509-2015 Field-Assembled Anodeless Riser Kits for Use on Outside Diameter Controlled Polyethylene
and Polyamide-11 (PA 11) Gas Distribution
Pipe and Tubing
Fuel Gas 1310.1.7.1(3)
ASTM F2620-2013 Standard Practice for Heat Fusion Joining of Polyethylene Pipe and Fittings Joints 1211.8(1), 1211.8(3)
ASTM F2623-2014 'Polyethylene of Raised Temperature (PE-RT) SDR9 Tubing Piping Table 1210.1
ASTM F2735-2009 (R2016) Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing Fittings Table 1210.1
ASTM F2769-2016 Polyethylene of Raised Temperature (PE-RT) Plastic Hot and Cold-Water Tubing and Distribution Systems Piping, Fittings Table 1210.1
ASTM F2855-2012 Specification for Chlorinated Poly (Vinyl Chloride)/Aluminum/Chlorinated Poly (Vinyl Chloride) (CPVC-AL-CPVC) Composite Piping, Plastic  Table 1210.1
AWS AS.8-2011 Filler Metals for Brazing and Braze Welding Joints 1211.4(1)
AWWA C110-2012 Ductile-Iron and Gray-Iron Fittings Fittings Table 1210.1
AWWA C111-2012 Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings Joints 1211.7(1)
AWWA C115-2011 Flanged Ductile-Iron Pipe with Ductile-Iron or Gray-Iron Treaded Flanges Piping Table 1210.1
AWWA C151-2009 Ductile-Iron Pipe, Centrifugally Cast Piping, Ferrous Table 1210.1
AWWA C153-2011 Ductile-Iron Compact Fittings Fittings Table 1210.1
AWWAC901-2008 Polyethylene (PE) Pressure Pipe and Tubing, 1/2 in. (13 mm) Through 3 in. (76 mm) for  Water Service Piping, Plastic Table 1210.1
CSA B137.1-2013 Polyethylene (PE) Pipe, Tubing, and Fittings for Cold-Water Pressure Services Piping Table 1210.1
CSA B137.2-2013 Polyvinylchloride (PVC) Injection-Moulded Gasketed Fittings for Pressure Applications Piping, Plastic Table 1210.1
CSA B137.3-2013 Rigid Polyvinylchloride (PVC) Pipe and Fittings for Pressure Applications Piping, Plastic Table 1210.1
CSA B137.5-2013 Crosslinked Polyethylene (PEX) Tubing Systems for Pressure Applications Piping Table 1210.1
CSA B137.6-2013 Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing, and Fittings for Hot-and Cold-Water Distribution Systems Piping, Plastic Table 1210.1
CSA B137.9-2013 Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-Pipe Systems Piping Table 1210.1
CSA B137.10-2013 Cross linked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Composite Pressure-Pipe Systems Piping Table 1210.1
CSA B137.11-2013 Polypropylene (PP-R) Pipe and Fittings for Pressure Applications Piping 1211.11(1)
CSA B137.18-2013 Polyethylene of Raised Temperature Resistance (PE-RT) Tubing Systems for Pressure Applications Piping, Plastic Table 1210.1
CSA FC 1-2014 Fuel Cell Technologies-Part 3-100: Stationary Fuel Cell Power Systems-Safety Fuel Cell Power Plants 1601.1
CSA LC 1-2016 Fuel Gas Piping Systems Using Corrugated  Stainless Steel Tubing (same as CSA 6.26) Fuel Gas 1308.5.3.4
CSA LC 4a-2013 Press-Connect Metallic Fittings For Use in Fuel Gas Distribution Systems (same as CSA 6.32a) Fuel Gas 1308.5.8.1, 1308.5.8.2
CSA Z21.8-1994 (R2012) Installation of Domestic Gas Conversion Burners Fuel Gas, Appliances 909.1
CSA Z21.10.1-2014 Gas Water Heaters-Volume I, Storage Water Heaters with Input Ratings of 75,000 Btu Per Hour or Less (same as CSA 4.1) Fuel Gas, Appliances Table 1203.2
CSA Z21.10.3-2015 Gas-Fired Water Heaters, Volume Ill, Storage Water Heaters with Input Ratings Above 75,000 Btu Per Hour, Circulating and lnstantaneous (same as CSA 4.3) Fuel Gas, Appliances Table 1203.2
CSA Z21.24-2015 Connectors for Gas Appliances (same as CSA 6.1 0) Fuel Gas 1312.1(3), 1312.2
CSA Z21.41-2014 Quick Disconnect Devices for Use with Gas Fuel Appliances (same as CSA 6.9) Fuel Gas 1312.7
CSA Z21.54-2014 Gas Hose Connectors for Portable Outdoor Gas-Fired Appliances (same as CSA 8.4) Fuel Gas 1312.3.2
CSA Z21.69-2015 Connectors for Moveable Gas Appliances (same as CSA 6.16) Fuel Gas 1312.1.1
CSA Z21.75-2016 Connectors for Outdoor Gas Appliances and Manufactured Homes (same as CSA 6.27) Appliances 1312.1(4)
CSA Z21.80a-2012 Line Pressure Regulators (same as CSA 6.22a) Fuel Gas 1308.7.1, 1308.7.4(1)
CSA Z21.90-2015 Gas Convenience Outlets and Optional Enclosures (same as CSA 6.24) Gas Outlets 1312.8
CSA Z21.93-2013 Excess Flow Valves for Natural and LP Gas with Pressures up to 5 psig (same as CSA 6.30) Fuel Gas 1309.1
CSA Z83.4-2015 Non-Recirculating Direct Gas-Fired Industrial Air Heaters (same as CSA 3.7) Air Heaters, Non-Recirculating, Non-Recirculating Heaters 914.1
CSA Z83.18-2015 Recirculating Direct Gas-Fired Industrial Air Heaters Air Heaters, Industrial Heaters, Recirculating 915.1
IlAR 2-2014 Standard for the Safe Design of Closed-Circuit Ammonia Refrigeration Systems Ammonia Refrigeration Systems 1102.2
IlAR 3-2012 Ammonia Refrigeration Valves Ammonia Refrigeration Systems 1102.2
IlAR 4-2015 Installation of Closed-Circuit Ammonia Refrigeration Systems Ammonia Refrigeration 1102.2
IlAR 5-2013 Start-Up and Commissioning of Closed Circuit Ammonia Refrigeration Systems Ammonia Refrigeration Systems 1102.2
MSS SP-58-2009 Pipe Hangers and Supports-Materials, Design, Manufacture, Selection, Application, and Installation Miscellaneous 11310.2.4
NEBB-2015 Procedural Standard for Testing, Adjusting and Balancing of Environmental Systems, 8th, Edition Balancing 314.1(4)
NFPA 2-2016 Hydrogen Technologies Code Gaseous Hydrogen Systems 937.1
NFPA 10-2013 Portable Fire Extinguishers Fire Extinguishing 513.12, 517.7.4
NFPA 12-2015 Carbon Dioxide Extinguishing Systems Fire Extinguishing 513.2.3(1)
NFPA 13-2016 Installation of Sprinkler Systems Miscellaneous 513.2.3(2), 517.7.6
NFPA 17-2017 Dry Chemical Extinguishing Systems Fire Extinguishing 513.2.3(3), 513.3.2
NFPA 17A-2017 Wet Chemical Extinguishing Systems Fire Extinguishing 513.2.3(4), 513.3.2
NFPA 30A-2015 Motor Fuel Dispensing Facilities and Repair Garages Miscellaneous 303.11.1
NFPA 31-2016 Installation of Oil-Burning Equipment Fuel Gas, Appliances 301.5, 1002.2.2, 1301.1
NFPA 37-2015 Installation and Use of Stationary Combustion Engines and Gas Turbines Generators 1602.1, 1602.3
NFPA 51-2013 Design and Installation of Oxygen-Fuel Gas Systems for Welding, Cutting, and Allied Processes Fuel Gas Systems 902.7
NFPA 52-2016 Vehicular Natural Gas Fuel Systems Code CNG Vehicle Fuel Systems 938.1
NFPA 54/2223.1-2015 National Fuel Gas Code Fuel Gas 516.2.1
NFPA 58-2017 Liquefied Petroleum Gas Code Fuel Gas 303.7, 516.2.1, 1308.5.4.2.3, 1308.5.9.4, 11310.5(6), 1312.11
NFPA 68-2013 Explosion Protection by Deflagration Venting Product Conveying Ducts 505.3.3
NFPA69-2014 Explosion Prevention Systems Explosion Prevention 505.3.1
NFPA 70-2017 National Electrical Code Miscellaneous 301.4, 511.1.6, 512.2.5516.2.7, 516.2.9(4), 602.2.1, 905.8.2, 1104.4(6), 1107.1.7, 1107.1.8, 1217.6.1, 1310.14.5(2), 1311.2.4, 1311.6
NFPA 80-2016 Fire Doors and Other Opening Protectives Fire Doors 510.7.7
NFPA 82-2014 Incinerators and Waste and Linen Handling Systems and Equipment Incinerator Chutes 802.2.8, Table 802.4, 925.1
NFPA 85-2015 Boiler and Combustion Systems Hazards Code Appliances 1002.1(3), 1011.1, Table 1003.2.1
NFPA 86-2015 Ovens and Furnaces Product Conveying Ducts 505.3.2
NFPA 88A-2015 Parking Structures Miscellaneous 303.11
NFPA 90A-2015 Installation of Air-Conditioning and Ventilating Systems HVAC 904.7
NFPA 90B-2015 Installation of Warm Air Heating and Air-Conditioning Systems HVAC 904.7
NFPA 96-2014 Ventilation Control and Fire Protection of Commercial Cooking Operations Commercial Cooking 922.4
NFPA 211-2016 Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances Fuel Gas Appliances 517.7, 517.7.1, 801.2, 801.3, 802.5.2, 802.5.3, 802.5.7.1, 802.5.7.3, 902.10
NFPA 221-2015 High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls Building Fire Walls, Fire Barrier 506.3
NFPA 262-2015 Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces Certification 602.2.1
NFPA 409-2016 Aircraft Hangars Miscellaneous 303.12
NFPA 654-2017 Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids Dust Explosion Prevention, Gutters 506.6, Table 505.9
NFPA 780-2017 Installation of Lightning Protection Systems Fuel Gas 1311.4
NFPA 853-2015 Installation of Stationary Fuel Cell Power Systems Fuel Cell Power Plants, Fuel Cells 1601.1
NFPA 1192-2015 Recreational Vehicles Fuel Gas Piping 1302.3
NSF 358-1-2014 Polyethylene Pipe and Fittings for Water Based Ground-Source "Geothermal" Heat Pump Systems Piping, Plastic Table 1210.1
NSF 358-2-2012 Polypropylene Pipe and Fittings for Water Based Ground-Source "Geothermal" Heat Pump Systems Piping, Plastic Table 1210.1
NSF 358-3-2016 Cross-linked polyethylene (PEX) pipe and fittings for water-based ground-source (geothermal) heat pump systems Piping, Plastic Table 1210.1
SMACNA-2002 HVAC Systems Testing, Adjusting and Balancing, 3rd Edition Balancing 314.1(5)
SMACNA-2006 HVAC Duct Construction Standards Metal and Flexible, 3rd Edition Ducts, Metal and Flexible 504.4.5, 506.2, 602.3603.3, 603.4, 603.5, 603.8603.10, 603.12, 604.1
SMACNA-2012 HVAC Air Duct Leakage Test Manual, 2nd Edition Ducts 603.10.1
SMACNA-2015 Phenolic Duct Construction Standards Duct Systems 602.4
UL 17-2008 Vent or Chimney Connector Dampers for Oil-Fired Appliances (with revisions through September 25, 2013) Vent Dampers 802.15.1
UL 103-2010 Factory-Built Chimneys for Residential Type and Building Heating Appliances (with revisions through July 27, 2012) Fuel Gas, Appliances 802.5.1.1, 802.5.1.2
UL 127-2011 Factory-Built Fireplaces (with revisions through July 27.2016) Fireplaces 802.5.1.1, 913.1, 913.1.1
UL 181-2013 Factory-Made Air Ducts and Air Connectors Air Connectors, Air Ducts 602.6, 603.4, 603.5603.8, 604.1.1
UL 181A-2013 Closure Systems for Use with Rigid Air Ducts Air Ducts 603.10, Table 603.10
UL 181B-2013 'Closure Systems for Use with Flexible Air Ducts and Air Connectors Air Connectors, Air Ducts 603.10, Table 603.10
UL 197-2010 Commercial Electric Cooking Appliances (with revisions through September 17, 2014)  Appliances, Commercial Cooking Electric Appliances 921.1
UL 207-2009 Refrigerant-Containing Components and Accessories, Nonelectrical (with revisions through June 27, 2014) Refrigeration Components 1109.2
UL 268A-2008 Smoke Detectors for Duct Application (with revisions through August 12, 2016) Smoke Detectors 608.1
UL 295-2007 Commercial-Industrial Gas Burners (with revisions through January 30, 2015) Gas Burners 910.2
UL 296-2003 Oil Burners (with revisions through June 11, 2015) Fuel Gas, Appliances 910.1
UL 300-2005 Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment (with revisions through December 16, 2014) Certification 513.2.2, 513.2.5517.3.1.1(6)
UL 378-2006 Draft Equipment (with revisions through September 17, 2013) Fuel Gas, Appliances 802.15.1
UL 391-2010 Solid-Fuel and Combination-Fuel Central and Supplementary Furnaces (with revisions through June 12, 2014) Furnaces, Solid Fuel 904.11
UL 412-2011 Refrigeration Unit Coolers (with revisions through September 17, 2013) Refrigeration 934.2
UL 427-2011 Refrigerating Units (with revisions through February 28, 2014) Refrigeration Systems 934.3
UL 441-2016 Gas Vents (with revisions through July 27, 2016) Fuel Gas 802.1
UL 467-2013 Grounding and Bonding Equipment Grounding and Bonding 1311.2.5
UL 471-2010 Commercial Refrigerators and Freezers (with revisions December 8, 2016) Freezers, Refrigerators 934.1
UL 499-2014 Electric Heating Appliances Kilns 931.4
UL 555-2006 Fire Dampers (with revisions through October 21, 2016) Dampers 605.2
UL 555C-2014 Ceiling Dampers Dampers 605.3
UL 555S-2014 Smoke Dampers (with revisions through October 27, 2016) Dampers '605.1
UL 641-2010 Type L Low-Temperature Venting Systems (with revisions through June 12, 2013) Equipment 802.1
UL 651-2011 Schedule 40, 80, Type EB and A Rigid PVC Conduit and Fittings (with revisions through June 15, 2016) Piping, Plastic 1308.5.4.1
UL 705-2004 Power Ventilators (with revisions through December 17, 2013) Power Ventilators 504.4.2.3
UL 710-2012 Exhaust Hoods for Commercial Cooking Equipment (with revisions through November 5, 2013) Exhaust Hoods, Hoods 507.3.1, 508.2, 508.2.1
UL 710B-2011 Recirculating Systems (with revisions through August 14, 2014) Exhaust Hoods 508.1, 513.2.2, 516.2.2516.2.3
UL 710C-2006 Ultraviolet Radiation Systems For Use In The Ventilation Control of Commercial Cooking Operations Exhaust Hoods, Hoods 508.2.1
UL 723-2008 Test for Surface Burning Characteristics of Building Materials (with revisions through August 12, 2013) Miscellaneous 508.3.4, 602.2, 604.1.21201.2
UL 726-1995 Oil-Fired Boiler Assemblies (with revisions through October 9, 2013) Fuel Gas, Appliances 1002.2.1
UL 727-2006 Oil-Fired Central Furnaces (with revisions through October 9, 2013) Fuel Gas, Appliances 904.12
UL 729-2003 Oil-Fired Floor Furnaces (with revisions through November 22, 2016) Furnaces, Floor, Oil Fired Furnaces 906.13
UL 730-2003 Oil-Fired Wall Furnaces (with revisions through November 22, 2016) Furnaces, Wall, Oil Fired 907.4
UL 731-1995 Oil-Fired Unit Heaters (with revisions through November 22, 2016) Heaters, Oil Fired 917.6
UL 737-2011 Fireplace Stoves (with revisions through August 19, 2015) Fireplace Stoves 913.2
UL 762-2013 Power Roof Ventilators for Restaurant Exhaust Appliances Ventilators 511.1
UL 778-2016 Motor operater Water Pumps (with revisions through February 22, 2017) Pumps 1208.1
UL 791-2006 Residential Incinerators (with revisions through November 7, 2014) Incinerators 925.3
UL 795-2016 Commercial-Industrial Gas Heating Equipment Heating Equipment, Gas Fired 904.13
UL 834-2004 Heating, Water Supply, and Power Boilers - Electric (with revisions through December 9, 2013) Appliances 1002.3, Table 1203.2
UL 858-2014 Household Electric Ranges (with revisions through April 6, 2016) Electric Ranges, Ranges 920.1
UL 867-2011 Electrostatic Air Cleaners (with revisions through September 16, 2016) Filters 936.1
UL 896-1993 Oil-Burning Stoves (with revisions through November 22, 2016) Stoves, Oil Fired 921.3
UL 900-2015 Air Filter Units Air Filters, Filters 311.2
UL 907-2016 Fireplace Accessories Fireplace Accessories 913.3
UL 921-2016 Commercial Dishwashers Appliances 519.1
UL 923-2013 Microwave Cooking Appliances (with revisions through November 18, 2015) Microwaves 920.3.2(3)
UL 959-2010 Medium Heat Appliance Factory-Built Chimneys (with revisions through June 12, 2014) Fuel Gas, Appliances 802.5.1.2
UL 1046-2010 Grease Filters for Exhaust Ducts (with revisions through January 13, 2012) Filters-Grease 509.1, 509.1.1, 518.1(4)
UL 1240-2005 I Electric Commercial Clothes-Drying Equipment (with revisions through October 17, 2012) Clothes Dryers, Commercial 908.1
UL 1479-2015 Fire Tests of Penetration Firestops Miscellaneous 1507.4.4, 507.4.5
UL 1482-2011 Solid-Fuel Type Room Heaters (with revisions through August 19, 2015) Room Heaters, Solid Fuel Heaters 802.5.1.1, 916.3
UL 1777-2015 Chimney Liners Chimneys, Liners 803.1.11.2
UL 1812-2013 Ducted Heat Recovery Ventilators (with revisions through April 17, 2014) Heat Recovery Ventilators 504.5
UL 1815-2012 Nonducted Heat Recovery Ventilators (with revisions through April 17, 2014) Heat Recovery Ventilators 504.5
UL 1820-2004 Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics (with revisions through May 10, 2013) Surface Burning Test, Pneumatic Tubing 602.2.3
UL 1887-2004 Fire Test of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics (with revisions through May 3, 2013) Surface Burning Test, Fi re Sprinkler Pipe 602.2.2
UL 1963-2011 Refrigerant Recovery/Recycling Equipment (with revisions through October 11, 2013) Refrigerant Equipment 1101.2
UL 1978-2010 Grease Ducts (with revisions through September 19, 2013) Ducts, Grease 507.3.1, 510.4.1, 510.5.2510.5.3
UL 1995-2015 Heating and Cooling Equipment HVAC, Electric 903.1, 904.14
UL 1996-2009 Electric Duct Heaters (with revisions through June 13, 2014) Duct Heaters 905.8
UL 2021-2015 Fixed and Location-Dedicated Electric Room Heaters Product, Heating, Electric 916.1
UL 2043-2013 Fire Test for Heat and Visible Smoke Release For Discrete Products and Their Accessories Installed in Air-Handling Spaces Surface Burning Test, Discrete Products 602.2.4
UL 2158-2015 Electric Clothes Dryers Clothes Dryers, Electric 908.1
UL 2158A-2013 Clothes Dryer Transition Duct Clothes Dryer Exhaust 504.4
UL 2162-2014 Commercial Wood-Fired Baking Ovens-Refractory Type Baking Ovens 921.2
UL 2200-2012 Stationary Engine Generator Assemblies (with revisions through July 29, 2015) Assemblies 1602.3
UL 2221-2010 Tests of Fire Resistive Grease Duct Enclosure Assemblies Duct Wrap, Grease Duct Enclosure 507.4.4
UL 2518-2005 Outline of Investigation for Air Dispersion Systems Materials Duct Systems 603.13
UL 2523-2009 Solid Fuel-Fired Hydronic Heating Appliances, Water Heaters, and Boilers (with revisions through February 8, 2013) Appliances 1002.4, Table 1203.2
UL 2790-2010 Commercial Incinerators (with revisions through October 8, 2014) Incinerators 925.2
UL 60335-2-40-2012 Household and Similar Electrical Appliances, Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers Appliances 903.1
The standards, publications, practices and guides listed in Table 1701.2 are not referenced in other sections of this code. The application of the referenced standards, publications, practices and guides shall be as specified in Section 302.1.2. The promulgating agency acronyms are found at the end of the table.

TABLE 17012
STANDARDS, PUBLICATIONS, PRACTICES, AND GUIDES
DOCUMENT NUMBER DOCUMENT TITLE APPLICATION
ACCA Manual J-2016 Residential Load Calculations Ducts
ACCA Manual N-2012 Commercial Load Calculations Ducts
ACCA Manual Q-1990 Low Pressure, Low Velocity Duct System Design Ducts
AHRI 1200-2013 Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets Commercial Refrigerated Display Merchandisers and Storage Cabinets
AHRI 1230-2010a Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment Refrigerants
AMCA 500-D-2012 Laboratory Methods of Testing Dampers for Rating Dampers
ASCE 25-2016 Earthquake-Actuated Automatic Gas Shutoff Devices Fuel Gas
ASHRAE 52.2-2012 General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size Cleaning Devices
ASHRAE 55-2013 Thermal Environmental Conditions for Human Occupancy Miscellaneous
ASHRAE 90.1-2016 Energy Standard for Buildings Except Low-Rise Residential Buildings Energy
ASHRAE 90.2-2007 Energy-Efficient Design of Low-Rise Residential Buildings Energy, Dwellings
ASHRAE 127-2012 Method of Testing for Rating Computer and Data Processing Room Unitary Air Conditioners Air Conditioners
ASHRAE/ACCA 183-2007 (R2014) Peak Cooling and Heating Load Calculations in Buildings Except Low-Rise Residential Buildings Cooling and Heating Load, Miscellaneous
ASHRAE Handbook-2012 HVAC Systems and Equipment Design
ASME A13.1-2007 (R2013) Scheme for the Identification of Piping Systems Piping
ASME A112.18.6/CSA B125.6-2009 (R2014) Flexible Water Connectors Piping
ASME B1.20.3-1976 (R2013) Dryseal Pipe Threads (Inch) Joints
ASME B16.33-2012 Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 175 psi (Sizes NPS 1/2 through NPS 2) Valves
ASME B16.50-2013 Wrought Copper and Copper Alloy Braze-Joint Pressure Fittings Fittings
ASTM A312/A312M-2016a Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes Piping, Ferrous
ASTM A568/A568M-2015 Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements for Piping
ASTM A653/A653M-2015e1 Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvan-nealed) by the Hot-Dip Process Piping, Ferrous
ASTM A733-2015 Welded and Seamless Carbon Steel and Austenitic Stainless Steel Pipe Nipples Piping, Ferrous
ASTM B370-2012 Standard Specification for Copper Sheet and Strip for Building Construction Miscellaneous
ASTM B687-1999 (R2016) Brass, Copper, and Chromium-Plated Pipe Nipples Piping, Copper Alloy
ASTM C518-2015 Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus Certification: Calibration, Error Analysis, Heat Flow Meter Apparatus, Heat Flux, Instrument Verification, Thermal Conductivity, Thermal Resistance, Thermal Testing, Tunnel Test
ASTM D93-2016a Flash Point by Pensky-Martens Closed Cup Tester Certification
ASTM D396-2016 Fuel Oils Boiler
ASTM D2517-2006 (R2011) Reinforced Epoxy Resin Gas Pressure Pipe and Fittings Piping, Plastic
ASTM E96/E96M-2016 Water Vapor Transmission of Materials Miscellaneous
ASTM E136-2016a Behavior of Materials in a Vertical Tube Furnace at 750°C Furnace
ASTM F1476-2007 (R2013) Performance of Gasketed Mechanical Couplings for Use in Piping Applications Joints
ASTM F2158-2008 (R2016) Residential Central-Vacuum Tube and Fittings Central Vacuum, Fittings, PVC, Tube
AWS B2.4-2012 Welding Procedure and Performance Qualification for Thermoplastics Joints, Certification
CSA C448-2016 Design and Installation of Ground Source Heat Pump Systems for Commercial and Residential Buildings Miscellaneous
CSA Z21.1-2016 Household Cooking Gas Appliances Household Cooking Appliances, Gas Fired
CSA Z21.5.1-2016 Gas Clothes Dyers-Volume I, Type I Clothes Dryers (same as CSA 7.1) Fuel Gas, Appliances
CSA Z21.5.2-2016 Gas Clothes Dryers-Volume II, Type 2 Clothes Dryers (same as CSA 7.2) Fuel Gas, Appliances
CSA Z21.11.2-2013 Gas-Fired Room Heaters, Volume II, Unvented Room Heaters Room Heaters, Unvented Heaters
CSA Z21.12b-1994 (R2010) Draft Hoods Fuel Gas, Appliances
CSA Z21.13-2014 Gas-Fired Low Pressure Steam and Hot Water Boilers (same as CSA 4.9) Fuel Gas, Appliances
CSA Z21.15b-2013 (R2014) Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves (same as CSA 9.1b) Fuel Gas
CSA Z21.17a-2008 Domestic Gas Conversion Burners (same as CSA 2.7a) Conversion Burner Installation, Gas Burners
CSA Z21.18b-2012 (R2012) Gas Appliance Pressure Regulators (same as CSA 6.3b) Appliance Regulators, Gas Refrigerators, Pressure
Regulators
CSA Z21.19-2014 Refrigerators Using Gas Fuel (same as CSA 1.4)
CSA Z21.20a-2008 Automatic Gas Ignition Systems and Components Automatic Ignition, Gas Ignition, Ignition
CSA Z21.21-2015 Automatic Valves for Gas Appliances (same as CSA 6.5) Appliance Valves, Automatic Gas Valves, Valves
CSA Z21.22-2015 Relief Valves for Hot Water Supply Systems (same as CSA 4.4) Valves
CSA Z21.40.1a-1997/CGA 2.91a-M97 (R2012) Gas-Fired, Heat Activated Air-Conditioning and Heat Pump Appliances Gas Fired Air Conditioning, Gas Fired Heat Pump
CSA Z21.42-2013 Gas-Fired Illuminating Appliances Illuminating Appliances
CSA Z21.47-2012 Gas-Fired Central Furnaces (same as CSA 2.3) Fuel Gas, Appliances
CSA Z21.50-2014 Vented Gas Fireplaces (same as CSA 2.22) Appliances, Decorative Appliances
CSA Z21.56-2014 Gas-Fired Pool Heaters (same as CSA 4.7) Fuel Gas, Swimming Pools, Spas, and Hot Tubs
CSA Z21.58-2015 Outdoor Cooking Gas Appliances (same as CSA 1.6) Cooking Appliances
CSA Z21.60-2012 Decorative Gas Appliances for Installation in Solid-Fuel Burning Fireplaces (same as CSA 2.26) Decorative Appliances, Decorative Fireplace Appliances
CSA Z21.61-1983 (R2004) Gas-Fired Toilets Toilets
CSA Z21.66-2015 Automatic Damper Devices for Use with Gas-Fired Appliances (same as CSA 6.14) Vent Dampers, Automatic Dampers
CSA Z21.71a-2005 (R2007) Automatic Intermittent Ignition Systems for Field Installation Automatic Pilot Ignition, Pilot Ignition
CSA Z21.86-2008 Vented Gas-Fired Space Heating Appliances (same as CSA 2.32) Fuel Gas Appliances
CSA Z21.88-2014 Vented Gas Fireplace Heaters (same as CSA 2.33) Fireplace Heaters
CSA Z83.8-2016 Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters, and Gas-Fired Duct Furnaces (same as CSA 2.6) Fuel Gas Appliances
CSA Z83.11-2016 Gas Food Service Equipment (same as CSA 1.8) Fuel Gas, Appliances
CSA Z83.19a-2011 Gas-Fired High-Intensity Infrared Heaters (same as CSA 2.35a) High Intensity Heaters, Infrared Heaters
CSA Z83.20b-2011 Gas-Fired Low-Intensity Infrared Heaters (same as CSA 2.34b) Infrared Heaters, Low Intensity Heaters
IAPMO IGC 293-2012 Tubing and Fittings for Special Hydronic Radiant Drywall Panels HVAC, Fittings, Tubing
IAPMO PS 117-2012ae1 Press and Nail Connections Fittings
IAPMO PS 120-2004 Flashing and Stand Combination for Air Conditioning Units (Residential or Commercial Unit Curb) Air Conditioning Flashing Stand
ISO 13256-1-1998 (R2012) Water Source Heat Pumps-Testing and Rating for Performance-Water-to-Air and Brine-to-Air Heat Pumps Water-Source Heat Pumps
ISO 13256-2-1998 Water Source Heat Pumps-Testing and Rating for Performance-Water-to-Water and Brine-to-Water Heat Pumps Water-Source Heat Pumps
MSS SP-67-2011 Butterfly Valves Valves
MSS SP-80-2013 Bronze Gate, Globe, Angle, and Check Valves Valves
MSS SP-104-2012 Wrought Copper Solder-Joint Pressure Fittings Fittings
MSS SP-106-2012 Cast Copper Alloy Flanges and Flanged Fittings: Class 125, 150, and 300 Fittings
MSS SP-109-2012 Weld-Fabricated Copper Solder-Joint Pressure Fittings Fittings
NFPA 30-2015 Flammable and Combustible Liquids Code Combustible Liquids, Flammable Liquids
NFPA 91-2015 Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Particulate Solids Product Conveying Ducts
NFPA 259-2013 Potential Heat of Building Materials Testing, Building Materials
NFPA 274-2013 Test Method to Evaluate Fire Performance Characteristics of Pipe Insulation Pipe Insulation
NFPA 501A-2017 Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities Miscellaneous
NFPA 5000-2015 Building Construction and Safety Code Miscellaneous
SAE 1512-1997 Automotive Tube Fittings Fittings
SMACNA-2003 Fibrous Glass Duct Construction Standard, 7th Edition Fiberglass Ducts
SMACNA-2008 IAQ Guidelines for Occupied Buildings Under Construction, 2nd Edition Ventilation
UL21-2014 LP-Gas Hose (with revisions through September 29, 2015) Hose, LPG Hose
UL 33-2010 Heat Responsive Links for Fire-Protection Service (with revisions through April 14, 2015) Fusible Links
UL 51-2013 Power-Operated Pumps and Bypass Valves for Anhydrous Ammonia, LP-Gas, and Propylene (with revisions through May 18, 2015) Ammonia Pumps, LPG Pumps, Pumps
UL 80-2007 Steel Tanks for Oil-Burner Fuels and Other Combustible Liquids (with revisions through January 16, 2014) Fuel Gas
UL 125-2014 Flow Control Valves for Anhydrous Ammonia and LP-Gas (with revisions through February 18, 2015) Fuel Gas
UL 132-2015 Safety Relief Valves for Anhydrous Ammonia and LP-Gas (with revisions through February 17, 2016) Fuel Gas
UL 144-2012 LP-Gas Regulators (with revisions through November 05, 2014) Fuel Gas
UL 174-2004 Household Electric Storage Tank Water Heaters (with revisions through April 10, 2015) Appliances
UL 180-2012 Liquid-Level Gauges for Oil Burner Fuels and other combustible liquids Gauges, Level Gauges
UL 252-2010 Compressed Gas Regulators (with revisions through January 28, 2015) Fuel Gas
UL 343-2008 Pumps for Oil-Burning Appliances (with revisions through June 12, 2013) Fuel Gas, Appliances
UL 353-1994 Limit Controls (with revisions through November 8, 2011) Controls
UL 404-2010 Gauges, Indicating Pressure, for Compressed Gas Service (with revisions through February 11, 2015) Fuel Gas
UL 429-2013 Electrically Operated Valves Valves
UL 443-2006 Steel Auxiliary Tanks for Oil-Burner Fuel (with revisions through March 8, 2013) Fuel Gas
UL 525-2008 Flame Arresters (with revisions through August 10, 2012) Flame Arrestors
UL 565-2013 Liquid-Level Gauges for Anhydrous Ammonia and LP-Gas Fuel Gas
UL 569-2013 Pigtails and Flexible Hose Connectors for LP-Gas Fuel Gas
UL 732-1995 Oil-Fired Storage Tank Water Heaters (with revisions through October 9, 2013) Fuel Gas, Appliances
UL 733-1993 Oil-Fired Air Heaters and Direct-Fired Heaters (with revisions through October 9, 2013) Water Heaters, Direct Fired, Oil Fired
UL 842-2015 Valves for Flammable Fluids Valves
UL 984-1996 Hermetic Refrigerant Motor-Compressors (with revisions through September 23, 2005) Compressors, Refrigeration
UL 1453-2016 Electric Booster and Commercial Storage Tank Water Heaters Appliances
UL 1746-2007 External Corrosion Protection Systems for Steel Underground Storage Tanks (with revisions through December 19, 2014) Tanks


ABBREVIATIONS IN TABLE 1701.1 AND TABLE 1701.2
AABC Associated Air Balance Council, 1518 K Street NW, Suite 503, Washington, DC 20005.
ACCA Air Conditioning Contractors of America Association, Inc., 2800 S Shirlington Road, Suite 300,Arlington, VA22206.
AHRI Air-Conditioning, Heating, and Refrigeration Institute, 2111 Wilson Boulevard, Suite 500, Arlington, VA22201.
AMCA Air Movement and Control Association, 30 West University Drive, Arlington Heights, IL 60004-1806.
ANSI American National Standards Institute, Inc., 25 W. 43rd Street, 4th Floor, New York, NY 10036.
ASCE American Society of Civil Engineers, 1801 Alexander Bell Drive, Reston, VA20191-4400.
ASHRAE American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329-2305.
ASME American Society of Mechanical Engineering, Two Park Avenue, New York, NY 10016-5990.
ASSE American Society of Sanitary Engineering, 18927 Hickory Creek Drive, Suite 220, Mokena, IL 60448.
ASTM ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.
AWS American Welding Society, 8669 NW 36 Street, #130, Miami, FL 33166-6672.
AWWA American Water Works Association, 6666 W. Quincy Avenue, Denver, CO 80235.
CGA Canadian Gas Association, 243 Consumers Road, Suite 1200, North York, Ontario, Canada M2J 5E3.
CSA Canadian Standards Association, 178 Rexdale Boulevard, Toronto, Ontario, Canada M9W 1R3.
e1 An editorial change since the last revision or reapproval.
IAPMO International Association of Plun1bing and Mechanical Officials, 4755 E. Philadelphia Street, Ontario, CA 91761.
IIAR International Institute of Ammonia Refrigeration, 1001 N. Fairfax Street, Suite 503, Alexandria, VA22314.
ISO International Organization for Standardization, 1 ch. de la Voie-Creuse, Casa Postale 56, CH-1211 Geneva 20, Switzerland.
MSS Manufacturers Standardization Society of the Valve and Fittings Industry, 127 Park Street NE, Vienna, VA22180.
NEBB NEBB, 8575 Grovemont Circle, Gaithersburg, MD 20877.
NFPA National Fire Protection Association, 1 Batterymarch Park, Quincy, MA02169-7471.
NSF NSF International, 789 N. Dixboro Road, Ann Arbor, MI48105.
SAE Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096.
SMACNA Sheet Metal and Air Conditioning Contractors National Association, 4201 Lafayette Center Drive, Chantilly, VA20151-1219.
UL Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING