Heads up: There are no amended sections in this chapter.
CALIFORNIA GREEN BUILDING STANDARDS CODE — MATRIX ADOPTION TABLE
CHAPTER 6 — REFERENCED ORGANIZATIONS AND STANDARDS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user.
See Chapter 1 for state agency authority and building applications.)
Adopting Agency BSC BSC-CG SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
1 2 1/AC AC SS 1 2 3 4
Adopt entire CA chapter X X X X X X
Adopt entire chapter as amended (amended sections listed below)
Adopt only those sections that are listed below
Chapter/Section

This chapter lists the organizations and standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard.

ORGANIZATIONSTANDARDREFERENCED SECTION
AHAM Association of Home Appliance Manufacturers
1119 19th Street NW, Suite 402ANSI/AHAM DW-1-2010202
Washington, D.C. 20026-3627
http://www.aham.org
AABC Associated Air Balance Council
1518 K St NWNational Standards, 1989 5.410.4.3.1
Washington, DC 20005A5.410.5.3.1
www.aabc.com
ACCA Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300ANSI/ACCA 2 Manual J—20114.507.2
Arlington, VA 22206ANSI/ACCA 1 Manual D—20144.507.2
www.acca.orgANSI/ACCA 3 Manual S—20144.507.2
ANSI American National Standards Institute
Operations OfficeANSI/AHAM DW-1-2010202
25 West 43rd Street, Fourth FloorNSF/ANSI 140-20144.504.3, 5.504.4.4
New York, NY 10036ANSI/ACCA 2 Manual J—20114.507.2
www.ansi.orgANSI/ACCA 1 Manual D—20144.507.2
ANSI/ACCA 3 Manual S—20144.507.2
ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE52.1-92A5.504.1
Atlanta, GA 3032952.2-2007202
www.ashrae.org62.2A5.504.1
90.15.108.8
ASME American Society of Mechanical Engineers
Three Park AvenueASME A112.18.15.303.6
New York, NY 10016-5990ASME A112.195.303.6
www.asme.orgASME A112.19.25.303.2
ASME A112.19.145.303.6
ASTM ASTM International
100 Barr Harbor DriveASTM C33A5.405.5.3.2
West Conshohocken, PA 19428-2859ASTM C150A5.405.5.1
www.astm.orgASTM C595A5.405.5.1
ASTM C618A5.405.5.2.1
ASTM C989A5.405.5.2.1
ASTM C1157A5.405.5.1
ASTM C1240A5.405.5.2.1
ASTM C1371-98A5.106.11.2.2
ASTM C1549-09(2014)A4.106.7, A5.106.11.1
ASTM C1602A5.405.5.3.2.3
ASTM C1697A5.405.5.2.1
ASTM E905.507.4
ASTM E408-02A5.10, 6.11.2.2
ASTM E4135.507.4
ASTM E13325.507.4
ASTM E1333-14Table 4.504.5, 5.504.4.5
ASTM E1903-11A5.103.4
ASTM E1918-06(2015)A4.106.7, A5.106.11.1
ASTM E1980-11A4.106.5.3, A5.106.11.2.3
CSA Canadian Standards Association
5060 Spectrum Way, Suite 100CSA B125.1, CSA O121,4.504.5.1
Mississauga, Ontario, Canada L4W 5N6CSA O151, CSA O153,
www.csa.caCSA O325
IAPMO International Association of Plumbing and Mechanical Officials
4755 E. Philadelphia St.IAPMO Z124.95.303.6
Ontario, CA 91761
iapmo@iapmo.org
IESNA Illuminating Engineering Society of North America
170 Wall St., Floor 17IES TM-15-115.10
New York, NY 10005-40016.6
http://www.ies.orgA4.106.10
NEBB National Environmental Balancing Bureau
8575 Grovemont CirProcedural Standards, 19835.410.4.3.1
Gaithersburg, MD 20877A5.410.5.3.1
http://nebb.org/index.php
NSF International
789 Dixboro Rd.NSF/ANSI 140-20074.504.3, 5.504.4.4
Ann Arbor, MI 48113-0140
http://www.nsf.org/
TABB Testing, Adjusting and Balancing Bureau
601 N Fairfax St, Ste 250National Standards, 20035.410.3.3.1
Alexandria, VA 22314A5.410.5.3.1
http://www.tabbcertified.org/contact.html
US EPA United States Environmental Protection Agency
Office of Wastewater Management (4204M)WaterSense4.303.1
1200 Pennsylvania Avenue
Washington, D.C. 20460
http://www.epa.gov/watersense/
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING