CHAPTER 16 — REFERNCED STANDARDS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user.
See Chapter 1 for state agency authority and building applications.)
Adopting Agency BSC BSC-CG SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
1 2 1/AC AC SS SS/CC 1 2 3 4
Adopt Entire Chapter
Adopt Entire Chapter as amended (amended sections listed below)
Adopt only those sections that are listed below X X
Chapter / Section
ASCE/SEI 7-10 X X
ASTM C 94-C94M-13 X X
ASTM F 2006-10 X X
ICC 300-12 X X
The state agency does not adopt sections identified with the following symbol: †
The Office of the State Fire Marshal's adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.


This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4, or California Administration Division I, as applicable.

ASCE/SEI

American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston VA 20191-4400
Standard
reference
number
TitleReferenced
in code
section number

7—10

Minimum Design Loads for Buildings and Other Structures with Supplement No. 1

301.1.4.1, 403.4, 403.9, A104

41—13

Seismic Evaluation and Retrofit of Existing Buildings

301.1.4, 301.1.4.1, Table 301.1.4.1, 301.1.4.2, Table 301.1.4.2, 402.4, Table 402.4, 403.4, 404.2.1, Table 404.2.1, 404.2.3, 407.4

ASHRAE

American Society of Heating, Refrigerating and Air Conditioning Engineers
1791 Tullie Circle, NE
Atlanta GA 30329
Standard
reference
number
TitleReferenced
in code
section number

62.1—2013

Ventilation for Acceptable Indoor Air Quality

809.2

ASME

American Society of Mechanical Engineers
3 Park Avenue
New York NY 10016
Standard
reference
number
TitleReferenced
in code
section number

ASME A17.1/CSA B44—2013

Safety Code for Elevators and Escalators

410.8.2, 705.1.2, 902.1.2

A17.3—2008

Safety Code for Existing Elevators and Escalators

902.1.2

A18.1—2008

Safety Standard for Platform Lifts and Stairway Chair Lifts

410.8.3, 705.1.3

ASTM

ASTM International
100 Barr Harbor Drive
West Conshohocken PA 19428-2959
Standard
reference
number
TitleReferenced
in code
section number

C 94/C94M—13

Specification for Ready-mixed Concrete

109.3.1

E 84—13A

Test Method for Surface Burning Characteristics of Building Materials

1205.9

E 108—11

Standard Test Methods for Fire Tests of Roof Coverings

1205.5

E 136—2012

Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C

202

F 2006—10

Standard Safety Specification for Window Fall Prevention Devices for Non Emergency Escape (Egress) and Rescue (Ingress) Windows

406.2, 702.4

F 2090—10

Standard Specification for Window Fall Prevention Devices with Emergency (Egress) Release Mechanisms

406.2, 702.4, 705.5

ICC

International Code Council, Inc.
500 New Jersey Avenue, NW, 6th Floor
Washington DC 20001
Standard
reference
number
TitleReferenced
in code
section number

CBC—16

California Building Code

101.4.1, 106.2.2, 109.3.3, 109.3.8, 110.2, 202, 301.1, 301.1.4, 301.1.4.1, 301.1.4.2401.2.3, 402.1, 402.2, 402.3, 402.3.1, 402.4, 403.1, 403.2, 403.3, 403.3.1, 403.4, 403.4.1, 403.8, 403.9, 404.2.1, 404.2.3, 404.3, 404.4, 404.5, 406.3, 407.1, 407.3, 407.4, 408.3, 410.4, 410.4.2, 410.6, 410.8.1, 410.8.4, 410.8.6, 410.8.5, 410.8.7, 410.8.8, 410.8.10, 410.8.14, 410.9, 410.9.3, 410.9.4, 501.3, 601.3, 602.3, 606.1, 606.2.2.1, 606.2.2.3, 606.2.3, 606.2.4 701.2, 701.3, 702.1, 702.2, 702.3, 702.4, 702.5, 702.6, 705.1, 705.1.1, 705.1.4, 705.1.7, 705.1.8, 705.1.9, 706.1, 706.3, 706.3.2, 707.2, 707.3.1, 707.3.2 801.3, 802.1, 803.2.1, 803.2.3, 803.3, 803.4, 803.5.2, 803.6, 804.1.1, 804.2, 804.2.2, 804.2.3, 804.2.4, 804.3, 805.3.1, 805.3.1.2.1, 805.4.3, 805.5, 805.6, 805.7.1, 805.8.1, 805.9.2, 805.10.1.1, 805.10.1.2, 805.10.1.3, 805.10.2, 805.11.2, 806.2, 806.3, 806.4, 806.5, 807.2, 807.4, 807.5, 807.6 904.1.2, 904.1.3, 904.2, 904.2.1, 904.2.2, 905.2, 905.3, 906.2, 907.4, 907.4.2 1001.3, 1002.1, 1002.2, 1007.1, 1007.2, 1007.3.1, 1011.1, 1012.1.1.1, 1012.1.1.2, 1012.2.1, 1012.2.2, 1012.3, 1012.4.1, 1012.4.2, 1012.4.3, 1012.5.1, 1012.5.1.1, 1012.5.3, 1012.6.1, 1012.6.3, 1012.7.1, 1012.7.2, 1012.7.3, 1012.8, 1012.8.2 1102.1, 1102.2, 1102.3, 1103.1, 1103.2, 1103.3, 1103.3.1, 1103.3.2, 1103.4, 1103.5, 1201.4, 1202.3, 1202.4, 1203.12, 1204.1, 1204.1.4, 1205.2, 1205.9, 1205.15, 1301.2, 1302.1, 1302.2, 1302.2.1, 1302.3, 1302.4, 1302.5, 1302.6, 1401.2.2, 1401.2.3, 1401.2.4, 1401.3.3, 1401.4.1, 1401.6.1, 1401.6.1.1, 1401.6.2, 1401.6.2.1, 1401.6.3.1, 1401.6.3.2, 1401.6.4.1, 1401.6.5, 1401.6.5.1, 1401.6.6, 1401.6.7.1, 1401.6.8, 1401.6.9, 1401.6.9.1, 1401.6.10, 1401.6.10.1, 1401.6.11, 1401.6.11.1, 1401.6.12.1, 1401.6.13, 1401.6.15.1, 1401.6.16.1, 1401.6.17, 1401.6.17.1, 1401.6.18, 1401.6.18.1, 1401.6.19, Table 1401.6.19, 1501.5, 1501.6.1, 1501.6.4.1, 1501.6.7, 1506.1, 1506.3

ICC A117.1—09

Accessible and Usable Buildings and Facilities

410.8.2, 410.8.3, 410.8.10, 705.1.2, 705.1.3

ICC 300—12

ICC Standard on Bleachers, Folding and Telescopic Seating and Grandstands

401.1

IECC—15

International Energy Conservation Code®

301.2, 702.6, 708.1, 811.1, 908.1

IFC—15

International Fire Code®

101.4.2, 301.1.1, 301.2, 402.5, 403.10, 803.2.1, 803.2.3, 804.4.1.1, 804.4.1.2, 804.4.1.3, 804.4.1.4, 804.4.1.5, 804.4.1.6, 804.4.1.7, 804.4.3, 1012.5.1.1, 1104.1, 1301.2, 1401.3.2, 1401.6.8.1, 1401.6.14, 1401.6.14.1, 1501.5, 1504.1, 1504.2

IFGC—15

International Fuel Gas Code®

301.2, 702.6.1

CMC—16

California Mechanical Code

301.2, 702.6, 809.1, 902.1.1, 902.2.1, 1009.1, 1401.6.7.1, 1401.6.8, 1401.6.8.1

CPC—16

California Plumbing Code

301.2, 609.1, 702.6, 810.1, 1010.1, 1010.2, 1010.3, 1010.5, 1501.7

IPMC—15

International Property Maintenance Code®

101.4.2, 301.2, 1301.2, 1401.3.2

CRC—16

California Residential Code

101.4.1, 301.2, 402.2, 403.2, 404.5, 408.3, 602.3, 701.3, 702.5, 706.2, 707.2, 707.4, 707.5, 708.1 807.4, 808.3, 811.1, 907.4, 908.1, 1103.2, 1103.3, 1103.4, 1104.1, 1106.1, 1201.4, 1301.2, 1302.1, 1302.2, 1302.2.1, 1302.3, 1302.4, 1302.6, 1302.5, 1401.2.2, 1401.2.3, 1401.3.3

NFPA

National Fire Protection Agency
1 Batterymarch Park
Quincy MA 02269-9101
Standard
reference
number
TitleReferenced
in code
section number

NFPA 13R—13

Standard for the Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height

804.2.5

NFPA 70—14

National Electrical Code

107.3, 301.2, 607.1.1, 607.1.2, 607.1.3, 607.1.4, 607.1.5, 808.1, 808.3.4, 808.3.7, 1008.1, 1008.2, 1008.3, 1008.4

NFPA 72—13

National Fire Alarm and Signaling Code

804.2.5, 804.4

NFPA 99—15

Health Care Facilities Code

607.1.4

NFPA 101—15

Life Safety Code

805.2

UL

UL LLC
333 Pfingsten Road
Northbrook IL 60062
Standard
reference
number
TitleReferenced
in code
section number

723—08

Standard for Test for Surface Burning Characteristics of Building Materials with Revisions Through September 2010

1205.9

790—04

Standard Test Methods for Fire Tests of Roof Coverings with Revisions through October 2008

1205.5