Heads up: There are no amended sections in this chapter.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

ANSI American National Standards Institute 25 West 43rd Street, Fourth Floor New York, NY 10036
Standard reference number Title Referenced in code section number
A118.10—99 Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin Set Ceramic Tile and Dimension Stone Installation 417.5.2.5
Z4.3—95 Minimum Requirements for Nonsewered Waste-disposal Systems 311.1
Z21.22—99 (R2003) Relief Valves for Hot Water Supply Systems with Addenda Z21.22a-2000 (R2003) and Z21.22b-2001 (R2003) 504.2, 504.4
Z124.1—95 Plastic Bathtub Units 407.1
Z124.2—95 Plastic Shower Receptors and Shower Stalls 417.1
Z124.3—95 Plastic Lavatories 416.1, 416.2, 417.1
Z124.4—96 Plastic Water Closet Bowls and Tanks 420.1
Z124.6—97 Plastic Sinks 415.1, 418.1
Z124.9—94 Plastic Urinal Fixtures 419.1
     
AHRI Air-Conditioning, Heating, & Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203
Standard reference number Title Referenced in code section number
1010—02 Self-contained, Mechanically Refrigerated Drinking-Water Coolers 410.1
     
ASME American Society of Mechanical Engineers Three Park Avenue New York, NY 10016-5990
Standard reference number Title Referenced in code section number
A112.1.2—2004 Air Gaps in Plumbing Systems Table 608.1, 608.13.1
A112.1.3—2000 Reaffirmed 2005 Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances Table 608.1, 608.13.1
A112.3.1—2007 Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum Applications Above and Below Ground 412.1, Table 702.1, Table 702.2, Table 702.3, Table 702.4, 708.2, Table 1102.4, Table 1102.5, 1102.6, Table 1102.7
A112.3.4—2000 (Reaffirmed 2004) Macerating Toilet Systems and Related Components 712.4.1
A112.4.1—1993 (R2002) Water Heater Relief Valve Drain Tubes 504.6
A112.4.3—1999 (Reaffirmed 2004) Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System 405.4
A112.6.1M—1997 (R2002) Floor-affixed Supports for Off-the-floor Plumbing Fixtures for Public Use 405.4.3
A112.6.2—2000 (Reaffirmed 2004) Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks 405.4.3
A112.6.3—2001
(Reaffirmed 2007)
2001 Floor and Trench Drains 412.1
A112.6.7—2001 (Reaffirmed 2007) Enameled and Epoxy-coated Cast-iron and PVC Plastic Sanitary Floor Sinks 427.1
A112.14.1—2003 Backwater Valves 715.2
A112.14.3—2000 Grease Interceptors 1003.3.4
A112.14.4—2001 (Reaffirmed 2007) Grease Removal Devices 1003.3.4
A112.18.1-2005/ Plumbing Supply Fittings 424.1, 424.2, 424.3, 607.4, 608.2 CSA B125.1-2005
A112.18.2-2005/ Plumbing Waste Fittings 424.1.2 CSA B125.2-2005
A112.18.3—2002 Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings 424.2, 424.6
A112.18.6—2003 Flexible Water Connectors 605.6
A112.18.7—1999 (Reaffirmed 2004) Deck mounted Bath/Shower Transfer Valves with Integral Backflow Protection 424.8
A112.19.1M—2004 (Reaffirmed 2004) Enameled Cast Iron Plumbing Fixtures 407.1, 410.1, 415.1, 416.1, 418.1
A112.19.2—2003 Vitreous China Plumbing Fixtures and Hydraulic Requirements for Water Closets and Urinals 401.2, 405.9, 408.1, 410.1, 416.1, 418.1, 419.1, 420.1
A112.19.3M—2000 (Reaffirmed 2007) Stainless Steel Plumbing Fixtures (Designed for Residential Use) 405.9, 415.1, 416.1, 418.1
A112.19.4M—1994 (Reaffirmed 2004) Porcelain Enameled Formed Steel Plumbing Fixtures 407.1, 416.1, 418.1
A112.19.5—2005 Trim for Water-closet Bowls, Tanks and Urinals 425.4
A112.19.6—1995 Hydraulic Performance Requirements for Water Closets and Urinals 419.1, 420.1
A112.19.7M—2006 Hydromassage Bathtub Appliances 421.1
A112.19.8M—2007 Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, Hot Tubs 421.4
A112.19.9M—1991(R2002) Nonvitreous Ceramic Plumbing Fixtures with 2002 Supplement 407.1, 408.1, 410.1, 415.1, 416.1, 417.1, 418.1, 420.1
A112.19.12—2006 Wall Mounted and Pedestal Mounted, Adjustable, Elevating, Tilting and Pivoting Lavatory, Sink and Shampoo Bowl Carrier Systems and Drain Systems 416.4, 418.3
A112.19.13—2001 (Reaffirmed 2007) Electrohydraulic Water Closets 420.1
A112.19.15— 2005 Bathtub/Whirlpool Bathtubs with Pressure Sealed Doors 407.4, 421.5
A112.19.19—2006 Vitreous China Nonwater Urinals 419.1
A112.21.2M—1983 Roof Drains 1102.6
A112.36.2M—1991(R2002) Cleanouts 708.2
B1.20.1—1983(R2006) Pipe Threads, General Purpose (inch) 605.10.3, 605.12.3, 605.14.4, 605.16.3, 605.18.1, 705.2.3, 705.4.3, 705.9.4, 705.12.1, 705.14.3
B16.3—2006 Malleable Iron Threaded Fittings Classes 150 and 300 Table 605.5, Table 702.4, Table 1102.7
B16.4—2006 Gray Iron Threaded Fittings Classes 125 and 250 Table 605.5, Table 702.4, Table 1102.7
B16.9—2003 Factory-made Wrought Steel Buttwelding Fittings Table 605.5, Table 702.4, Table 1102.7
B16.11—2005 Forged Fittings, Socket-welding and Threaded Table 605.5, Table 702.4, Table 1102.7
B16.12—1998 (Reaffirmed 2006) Cast-iron Threaded Drainage Fittings Table 605.5, Table 702.4, Table 1102.7
B16.15—2006 Cast Bronze Threaded Fittings Table 605.5, Table 702.4, Table 1102.7
B16.18—2001 (Reaffirmed 2005) Cast Copper Alloy Solder Joint Pressure Fittings Table 605.5, Table 702.4, Table 1102.7
B16.22—2001 (Reaffirmed 2005) Wrought Copper and Copper Alloy Solder Joint Pressure Fittings Table 605.5, Table 702.4, Table 1102.7
B16.23—2002 (Reaffirmed 2006) Cast Copper Alloy Solder Joint Drainage Fittings DWV Table 605.5, Table 702.4, Table 1102.7
B16.26—2006 Cast Copper Alloy Fittings for Flared Copper Tubes Table 605.5, Table 702.4, Table 1102.7
B16.28—1994 Wrought Steel Buttwelding Short Radius Elbows and Returns Table 605.5, Table 702.4, Table 1102.7
B16.29—2001 Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings (DWV) Table 605.5, Table 702.4, Table 1102.7
     
ASSE American Society of Sanitary Engineering 901 Canterbury Road, Suite A Westlake, OH 44145
Standard reference number Title Referenced in code section number
1001—02 Performance Requirements for Atmospheric Type Vacuum Breakers 425.2, Table 608.1, 608.13.6, 608.16.4.1
1002—99 Performance Requirements for Antisiphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks 425.3.1, Table 608.1
1003—01 Performance Requirements for Water Pressure Reducing Valves 604.8
1004—90 Performance Requirements for Backflow Prevention Requirements for Commercial Dishwashing Machines 409.1
1005—99 Performance Requirements for Water Heater Drain Valves 501.3
1006—89 Performance Requirements for Residential Use Dishwashers 409.1
1007—92 Performance Requirements for Home Laundry Equipment 406.1, 406.2
1008—89 Performance Requirements for Household Food Waste Disposer Units 413.1
1009—90 Performance Requirements for Commercial Food Waste Grinder Units 413.1
1010—04 Performance Requirements for Water Hammer Arresters 604.9
1011—04 Performance Requirements for Hose Connection Vacuum Breakers Table 608.1, 608.13.6
1012—02 Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent Table 608.1, 608.13.3, 608.16.2
1013—05 Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Fire Protection Principle Backflow Preventers Table 608.1, 608.13.2, 608.16.2
1015—05 Performance Requirements for Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies Table 608.1, 608.13.7
1016—96 Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings 424.3, 424.4, 607.4
1017—03 Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution Systems 501.2, 613.1
1018—01 Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied 1002.4
1019—04 Performance Requirements for Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Draining Type Table 608.1, 608.13.6
1020—04 Performance Requirements for Pressure Vacuum Breaker Assembly Table 608.1, 608.13.5
1022—03 Performance Requirements for Backflow Preventer for Beverage Dispensing Equipment Table 608.1, 608.16.1, 608.16.10
1024—04 Performance Requirements for Dual Check Valve Type Backflow Preventers (for Residential Supply Service or Individual Outlets). 605.3.1, Table 608.1
1035—02 Performance Requirements for Laboratory Faucet Backflow Preventers Table 608.1, 608.13.6
1037—90 Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures 425.2
1044—01 Performance Requirements for Trap Seal Primer Devices Drainage Types and Electronic Design Types 1002.4
1047—05 Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies Table 608.1, 608.13.2
1048—05 Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies Table 608.1, 608.13.7
1050—02 Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems 917.1
1051—02 Performance Requirements for Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems-fixture and Branch Devices 917.1
1052—04 Performance Requirements for Hose Connection Backflow Preventers Table 608.1, 608.13.6
1055—97 Performance Requirements for Chemical Dispensing Systems 608.13.9
1056—01 Performance Requirements for Spill Resistant Vacuum Breaker Table 608.1, 608.13.5, 608.13.8
1060—96 Performance Requirements for Outdoor Enclosures for Backflow Prevention Assemblies 608.14.1
1061—06 Performance Requirements for Removable and Nonremovable Push Fit Fittings Table 605.5
1062—97 Performance Requirements for Temperature Actuated, Flow Reduction Valves to Individual Fixture Fittings 424.7
1066—97 Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings 604.11
1069—05 Performance Requirements for Automatic Temperature Control Mixing Valves 424.4
1070—04 Performance Requirements for Water-temperature Limiting Devices 408.3, 416.5, 424.5, 607.1
1079—2005 Dielectric Pipe Unions 605.24.1, 605.24.3
5013—98 Performance Requirements for Testing Reduced Pressure Principle Backflow Prevention Assembly (RPA) and Reduced Pressure Fire Protection Principle Backflow Preventers (RFP) 312.10.2
5015—98 Performance Requirements for Testing Double Check Valve Backflow Prevention Assembly (DCVA) 312.10.2
5020—98 Performance Requirements for Testing Pressure Vacuum Breaker Assembly (PVBA) 312.10.2
5047—98 Performance Requirements for Testing Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies (RPDA) 312.10.2
5048—98 Performance Requirements for Testing Double Check Valve Detector Assembly (DCDA) 312.10.2
5052—98 Performance Requirements for Testing Hose Connection Backflow Preventers 312.10.2
5056—98 Performance Requirements for Testing Spill Resistant Vacuum Breaker 312.10.2
     
ASTM ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959
Standard reference number Title Referenced in code section number
A 53/A 53M—06a Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless Table 605.3, Table 605.4, Table 702.1
A 74—06 Specification for Cast-iron Soil Pipe and Fittings Table 702.1, Table 702.2, Table 702.3, Table 702.4, 708.2, 708.7, Table 1102.4, Table 1102.5, Table 1102.7
A 312/A 312M—06 Specification for Seamless and Welded Austenitic Stainless Steel Pipes Table 605.3, Table 605.4, Table 605.5, 605.23.2
A 733—03 Specification for Welded and Seamless Carbon Steel and Austenitic Stainless Steel Pipe Nipples Table 605.8
A 778—01 Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products Table 605.3, Table 605.4, Table 605.5
A 888—07a Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Application Table 702.1, Table 702.2, Table 702.3, Table 702.4, 708.7, Table 1102.4, Table 1102.5, Table 1102.7
B 32—04 Specification for Solder Metal 605.14.3, 605.15.4, 705.9.3, 705.10.3
B 42—02e01 Specification for Seamless Copper Pipe, Standard Sizes Table 605.3, Table 605.4, Table 702.1
B 43—98(2004) Specification for Seamless Red Brass Pipe, Standard Sizes Table 605.3, Table 605.4, Table 702.1
B 75—02 Specification for Seamless Copper Tube Table 605.3, Table 605.4, Table 702.1, Table 702.2, Table 702.3, Table 1102.4
B 88—03 Specification for Seamless Copper Water Tube Table 605.3, Table 605.4, Table 702.1, Table 702.2, Table 702.3, Table 1102.4
B 152/B 152M—06a Specification for Copper Sheet, Strip Plate and Rolled Bar 402.3, , 417.5.2.4, 425.3.3, 902.2
B 251—02e01 Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube Table 605.3, Table 605.4, Table 702.1, Table 702.2, Table 702.3, Table 1102.4
B 302—02 Specification for Threadless Copper Pipe, Standard Sizes Table 605.3, Table 605.4, Table 702.1
B 306—02 Specification for Copper Drainage Tube (DWV) Table 702.1, Table 702.2, Table 1102.4
B 447—07 Specification for Welded Copper Tube Table 605.3, Table 605.4
B 687—99(2005)e01 Specification for Brass, Copper and Chromium-plated Pipe Nipples Table 605.8
B 813—00e01 Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube 605.14.3, 605.15.4, 705.9.3, 705.10.3
B 828—02 Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings 605.14.3, 605.15.4, 705.9.3, 705.10.3
C 4—04e01 Specification for Clay Drain Tile and Perforated Clay Drain Tile Table 702.3, Table 1102.4, Table 1102.5
C 14—07 Specification for Nonreinforced Concrete Sewer, Storm Drain and Culvert Pipe Table 702.3, Table 1102.4
C 76—07 Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe Table 702.3, Table 1102.4
C 296—(2004)e01 Specification for Asbestos-cement Pressure Pipe Table 605.3
C 425—04 Specification for Compression Joints for Vitrified Clay Pipe and Fittings 705.15, 705.19
C 428—97(2006) Specification for Asbestos-cement Nonpressure Sewer Pipe Table 702.2, Table 702.3, Table 702.4, Table 1102.4
C 443—05a Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets 705.6, 705.19
C 508—00(2004) Specification for Asbestos-cement Underdrain Pipe Table 1102.5
C 564—04a Specification for Rubber Gaskets for Cast-iron Soil Pipe and Fittings 705.5.2, 705.5.3, 705.19, Table 1102.4
C 700—07 Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated Table 702.3, 702.4, Table 1102.4, Table 1102.5
C 1053—00(2005) Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications Table 702.1, Table 702.4
C 1173—06 Specification for Flexible Transition Couplings for Underground Piping System 705.2.1, 705.7.1, 705.14.1, 705.15, 705.16.1, 705.19
C 1277—06 Specification for Shielded Coupling Joining Hubless Cast-iron Soil Pipe and Fittings 705.5.3
C 1440—03 Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste,and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems 705.19
C 1460—04 Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground 705.19
C 1461—06 Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use 705.19
C 1540—04 Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings 705.5.3
C 1563—04 Standard Test Method for Gaskets for Use in Connection with Hub and Spigot Cast Iron Soil Pipe and Fittings for Sanitary Drain, Waste, Vent and Storm Piping Applications. 705.5.2
D 1527—99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80 Table 605.3
D 1785—06 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120 Table 605.3
D 1869—95(2005) Specification for Rubber Rings for Asbestos-cement Pipe 605.11, 605.24, 705.3, 705.19
D 2235—04 Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings 605.10.2, 705.2.2, 705.7.2
D 2239—03 Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter Table 605.3
D 2241—05 Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series) Table 605.3
D 2282—(2005)99e01 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR) Table 605.3
D 2464—06 Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 Table 605.5, Table 1102.7
D 2466—06 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 Table 605.5, Table 1102.7
D 2467—06 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 Table 605.5, Table 1102.7
D 2468—96a Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40 Table 605.5, Table 1102.7
D 2564—04e01 Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems 605.21.2, 705.8.2, 705.14.2
D 2609—02 Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe Table 605.5, Table 1102.7
D 2657—07 Practice for Heat Fusion-joining of Polyolefin Pipe and Fitting 605.19.2, 705.16.1
D 2661—06 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings Table 702.1, Table 702.2, Table 702.3, Table 702.4, 705.2.2, 705.7.2, Table 1102.4, Table 1102.7
D 2665—07 Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.7
D 2672—96a(2003) Specification for Joints for IPS PVC Pipe Using Solvent Cement Table 605.3
D 2683—04 Standard Specification for Socket-type Polyethylene fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing Table 605.5
D 2729—04e01 Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings Table 1102.5
D 2737—03 Specification for Polyethylene (PE) Plastic Tubing Table 605.3
D 2751—05 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings Table 702.3, Table 702.4, Table 1102.7
D 2846/D 2846M—06 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold Water Distribution Systems Table 605.3, Table 605.4, Table 605.5, 605.16.2
D 2855—96(2002) Standard Practice for Making Solvent-cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings 605.22.2, 705.8.2, 705.14.2
D 2949—01ae01 Specification for 3.25-in Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings Table 702.1, Table 702.2, Table 702.3, Table 702.4
D 3034—06 Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings Table 702.3, Table 702.4, Table 1102.7, Table 1102.4
D 3035-03 Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter Table 605.3
D 3139—98(2005) Specification for Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals 605.10.1, 605.22.1
D 3212—96a(2003)e01 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals 705.2.1, 705.8.1, 705.14.1, 705.16.2
D 3261—03 Standard Specification for Butt Heat Fusion Polyethylene (PE) Plastic fittings for Polyethylene (PE) Plastic Pipe and Tubing Table 605.5
D 3311—06a Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns Table 1102.7
D 4068—01 Specification for Chlorinated Polyethlene (CPE) Sheeting for Concealed Water-containment Membrane 417.5.2.2
D 4551—96(2001) Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-containment Membrane 417.5.2.1
F 405—05 Specification for Corrugated Polyethylene (PE) Tubing and Fittings Table 1102.5
F 409—02 Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings 424.1.2, Table 1102.7
F 437—06 Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 Table 605.5
F 438—04 Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40 Table 605.5
F 439—06 Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 Table 605.5
F 441/F 441M—02 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80 Table 605.3, Table 605.4
F 442/F 442M—99(2005) Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR) Table 605.3, Table 605.4
F 477—07 Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe 605.24, 705.19
F 493—04 Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings 605.16.2
F 628—06e01 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core Table 702.1, Table 702.2, Table 702.3, Table 702.4, 705.2.2, 705.7.2, Table 1102.4, Table 1102.7
F 656—02 Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings .605.22.2, 705.8.2, 705.14.2
F 714—06a Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter Table 702.3
F 876—06 Specification for Cross-linked Polyethylene (PEX) Tubing Table 605.3, Table 605.4
F 877—07 Specification for Cross-linked Polyethylene (PEX) Plastic Hot and Cold Water Distribution Systems Table 605.3, Table 605.4, Table 605.5
F 891—04 Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core Table 702.1 Table 702.2, Table 702.3, Table 1102.4, Table 1102.5, Table 1102.7
F 1055—98(2006) Standard Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene Pipe and Tubing Table 605.5
F 1281—07 Specification for Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene (PEX-AL-PEX) Pressure Pipe Table 605.3, Table 605.4, Table 605.5, 605.21.1
F 1282—06 Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe Table 605.3, Table 605.4, Table 605.5, 605.21.1
F 1412—01e01 Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage Table 702.1, Table 702.2, Table 702.4, 705.17.1
F 1488—03 Specification for Coextruded Composite Pipe Table 702.1, Table 702.2, Table 702.3
F 1673—04 Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems Table 702.1, Table 702.2, Table 702.3, Table 702.4, 705.18.1
F 1807—07 Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing Table 605.5
F 1866—07 Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings Table 702.4, Table 1102.7
F 1960—07 Specification for Cold Expansion Fittings with PEX Reinforcing Rings for use with Cross-linked Polyethylene (PEX) Tubing Table 605.5
F 1974—04 Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe Table 605.5, 605.21.1
F 1986—01(2006) Specification for Multilayer Pipe, Type 2, Compression Fittings and Compression Joints for Hot and Cold Drinking Water Systems Table 605.3, Table 605.4, Table 605.5
F 2080—05 Specifications for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe Table 605.5
F 2098—04e01 Standard specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert Fittings Table 605.5
F 2159—05 Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing Table 605.5
F 2262—05 Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Tubing OD Controlled SDR9 Table 605.3, Table 605.4
F 2306/F 2306M-05 12" to 60" Annular Corrugated Profile-wall Polyethylene (PE) Pipe and Fittings for Gravity Flow Storm Sewer and Subsurface Drainage Applications Table 1102.4, Table 1102.7
F 2389—06 Specification for Pressure-rated Polypropylene (PP) Piping Systems Table 605.3, Table 605.4, Table 605.5, 605.20.1
F 2434—05 Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/ Aluminum/Cross-linked Polyethylene (PEX AL-PEX) Tubing Table 605.5
     
AWS American Welding Society 550 N.W. LeJeune Road Miami, FL 33126
Standard reference number Title Referenced in code section number
A5.8—04 Specifications for Filler Metals for Brazing and Braze Welding 605.12.1, 605.14.1, 605.15.1, 705.4.1, 705.9.1, 705.10.1
     
AWWA American Water Works Association 6666 West Quincy Avenue Denver, CO 80235
Standard reference number Title Referenced in code section number
C104—98 Standard for Cement-mortar Lining for Ductile-iron Pipe and Fittings for Water 605.3, 605.5
C110—/A21.10—03 Standard for Ductile-iron and Gray-iron Fittings, 3 Inches through 48 Inches, for Water Table 605.5, Table 702.4, Table 1102.7
C111—00 Standard for Rubber-gasket Joints for Ductile-iron Pressure Pipe and Fittings 605.13
C115/A21.15—99 Standard for Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges Table 605.3, Table 605.4
C151/A21.51—02 Standard for Ductile-iron Pipe, Centrifugally Cast for Water Table 605.3, Table 605.4
C153—00/A21.53—00 Standard for Ductile-iron Compact Fittings for Water Service Table 605.5
C510—00 Double Check Valve Backflow Prevention Assembly Table 608.1, 608.13.7
C511—00 Reduced-pressure Principle Backflow Prevention Assembly Table 608.1, 608.13.2, 608.16.2
C651—99 Disinfecting Water Mains 610.1
C652—02 Disinfection of Water-storage Facilities 610.1
     
CISPI Cast Iron Soil Pipe Institute 5959 Shallowford Road, Suite 419 Chattanooga, TN 37421
Standard reference number Title Referenced in code section number
301—04a Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications Table 702.1, Table 702.2, Table 702.3, Table 702.4, 708.7, Table 1102.4, Table 1102.5, Table 1102.7
310—04 Specification for Coupling for Use in Connection with Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications 705.5.3
     
CSA Canadian Standards Association 5060 Spectrum Way. Mississauga, Ontario, Canada L4W 5N6
Standard reference number Title Referenced in code section number
B45.1—02 Ceramic Plumbing Fixtures 408.1, 416.1, 418.1, 419.1, 420.1
B45.2—02 Enameled Cast-iron Plumbing Fixtures 407.1, 415.1, 416.1, 418.1
B45.3—02 Porcelain Enameled Steel Plumbing Fixtures 407.1, 416.1, 418.1
B45.4—02 Stainless-steel Plumbing Fixtures 415.1, 416.1, 418.1, 420.1
B45.5—02 Plastic Plumbing Fixtures 407.1, 416.2, 417.1, 419.1, 420.1, 421.1
B45.9—99 Macerating Systems and Related Components 712.4.1
B64.1.2—01 Vacuum Breakers, Pressure Type (PVB) Table 608.1, 608.13.5
B64.2.1—01 Vacuum Breakers, Hose Connection Type (HCVB) with Manual Draining Feature Table 608.1, 608.13.6
B64.2.1.1—01 Vacuum Breakers, Hose Connection Dual Check Type (HCDVB) Table 608.1, 608.13.6
B64.4.1—01 Backflow Preventers, Reduced Pressure Principle Type for Fire Sprinklers (RPF) Table 608.1, 608.13.2
B64.5—01 Backflow Preventers, Double Check Type (DCVA) Table 608.1, 608.13.7
B64.5.1—01 Backflow Preventers, Double Check Type for Fire Systems (DCVAF) Table 608.1 608.13.7
B64.6—01 Backflow Preventers, Dual Check Valve Type (DuC) 605.3.1, Table 608.1
B64.7—94 Vacuum Breakers, Laboratory Faucet Type (LFVB Table 608.1, 608.13.6
B64.10/B64.10.1—01 Manual for the Selection and Installation of Backflow Prevention Devices/Manual for the Maintenance and Field Testing of Backflow Prevention Devices 312.10.2
B79—94(2000) Floor, Area and Shower Drains, and Cleanouts for Residential Construction 412.1
B125—01 Plumbing Fittings 424.4, 424.6, 425.4
B125.1/ ASME A112.18.1—05 Plumbing Supply Fittings 424.1, 424.2, 424.3, 607.4, 608.2
B125.2/ASME A112.18.2—05 Plumbing Waste Fittings 424.1.2
B125.3—2005 Plumbing Fittings 416.5, 424.5, 425.3.1, Table 608.1
B137.1—02 Polyethylene Pipe, Tubing and Fittings for Cold Water Pressure Services Table 605.3
B137.2—02 PVC Injection-moulded Gasketed Fittings for Pressure Applications Table 605.5, Table 1102.7
B137.3—02 Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications Table 605.3, Table 605.4, Table 605.5, 605.22.2, 705.8.2, 705.14.2
B137.5—02 Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications— with Revisions through September 1992 Table 605.3, Table 605.4, Table 605.5
B137.6—02 CPVC Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems— with Revisions through May 1986 .Table 605.3, Table 605.4
B137.11—02 Polypropylene (PP-R) Pipe and Fittings for Pressure Applications Table 605.3, Table 605.4, Table 605.5
B181.1—02 ABS Drain, Waste and Vent Pipe and Pipe Fittings Table 702.1, Table 702.2, Table 702.3, Table 702.4, 705.2.2, 705.7.2, 715.2, Table 1102.4, Table 1102.7
B181.2—02 PVC Drain, Waste, and Vent Pipe and Pipe Fittings— with Revisions through December 1993 Table 702.1 Table 702.2, 705.8.2, 705.14.2, 715.2
B182.1—02 Plastic Drain and Sewer Pipe and Pipe Fittings 705.8.2, 705.14.2, Table 1102.4
B182.2—02 PVC Sewer Pipe and Fittings (PSM Type) Table 702.3, Table 1102.4, Table 1102.5
B182.4—02 Profile PVC Sewer Pipe and Fittings Table 702.3, Table 1102.4, Table 1102.5
B182.6—02 Profile Polyethylene Sewer Pipe and Fittings for Leak-proof Sewer Applications Table 1102.5
B182.8—02 Profile Polyethylene Storm Sewer and Drainage Pipe and Fittings Table 1102.5
CAN/CSA-A257.1M—92 Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings Table 702.3, Table 1102.4
CAN/CSA-A257.2M—92 Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings Table 702.3, Table 1102.4
CAN/CSA-A257.3M—92 Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and Fittings Using Rubber Gaskets 705.6, 705.19
CAN/CSA-B64.1.1—01 Vacuum Breakers, Atmospheric Type (AVB) 425.2, Table 608.1, 608.13.6
CAN/CSA-B64.2—01 Vacuum Breakers, Hose Connection Type (HCVB) Table 608.1, 608.13.6
CAN/CSA-B64.2.2—01 Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature Table 608.1, 608.13.6
CAN/CSA-B64.3—01 Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP) Table 608.1, 608.13.3, 608.16.2
CAN/CSA-B64.4—01 Backflow Preventers, Reduced Pressure Principle Type (RP) Table 608.1, 608.13.2, 608.16.2
CAN/CSA-B64.10—01 Manual for the Selection, Installation, Maintenance and Field Testing of Backflow Prevention Devices 312.10.2
CAN/CSA-B137.9—02 Polyethylene/Aluminum/Polyethylene Composite Pressure Pipe Systems Table 605.3, Table 605.5, 605.21.1
CAN/CSA-B137.10M—02 Cross-linked Polyethylene/Aluminum/Polyethylene Composite Pressure Pipe Systems Table 605.3, Table 605.4, Table 605.5, 605.21.1
CAN/CSA-B181.3—02 Polyolefin Laboratory Drainage Systems Table 702.1, Table 702.2, Table 702.4, 705.17.1
CAN/CSA-B182.4—02 Profile PVC Sewer Pipe and Fittings Table 702.3, Table 1102.4, Table 1102.5
CAN/CSA-B602—02 Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe 705.2.1, 705.5.3, 705.6, 705.7.1, 705.14.1, 705.15, 705.16.2, 705.19
     
ICC International Code Council, Inc. 500 New Jersey Ave, NW 6th Floor Washington, DC 20001
Standard reference number Title Referenced in code section number
IBC—09 International Building Code® 201.3, 305.4, 307.1, 307.2, 307.3, 308.2, 309.1,310.1, 310.3, 403.1, Table 403.1, 404.1, 407.3, 417.6, 502.6, 606.5.2, 1106.5
IEBC—09 International Existing Building Code 101.2
IECC—09 International Energy Conservation Code 313.1, 607.2, 607.2.1
IFC—09 International Fire Code® 201.3, 1201.1
IFGC—09 International Fuel Gas Code® 101.2, 201.3, 502.1
IMC—09 International Mechanical Code® 201.3, 307.6, 310.1, 422.9, 502.1, 612.1, 1202.1
IPSDC—09 International Private Sewage Disposal Code® 701.2
IRC—09 International Residential Code 101.2
     
ISEA International Safety Equipment Association 1901 N. Moore Street, Suite 808 Arlington, VA 22209
Standard reference number Title Referenced in code section number
Z358.1—98 Emergency Eyewash and Shower Equipment 411.1
     
NFPA National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471
Standard reference number Title Referenced in code section number
50—01 Bulk Oxygen Systems at Consumer Sites 1203.1
51—07 Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes 1203.1
70—08 National Electric Code 502.1, 504.3, 1113.1.3
99C—05 Gas and Vacuum Systems 1202.1
     
NSF NSF International 789 Dixboro Road Ann Arbor, MI 48105
Standard reference number Title Referenced in code section number
3—2007 Commercial Warewashing Equipment 409.1
14—2007 Plastic Piping System Components and Related Materials 303.3, 611.3
18—2007 Manual Food and Beverage Dispensing Equipment 426.1
42—2007e Drinking Water Treatment Units—Aesthetic Effects 611.1, 611.3
44—2004 Residential Cation Exchange Water Softeners 611.1, 611.3
53—2007 Drinking Water Treatment Units—Health Effects 611.1, 611.3
58—2006 Reverse Osmosis Drinking Water Treatment Systems 611.2
61—2007a Drinking Water System Components—Health Effects 410.1, 424.1, 605.3, 605.4, 605.5, 605.7, 611.3, 611.3
62—2004 Drinking Water Distillation Systems 611.1
     
PDI Plumbing and Drainage Institute 800 Turnpike Street, Suite 300 North Andover, MA 01845
Standard reference number Title Referenced in code section number
G101(2003) Testing and Rating Procedure for Grease Interceptors with Appendix of Sizing and Installation Data 1003.3.4
     
UL Underwriters Laboratories, Inc. 333 Pfingsten Road Northbrook, IL 60062-2096
Standard reference number Title Referenced in code section number
UL508—99 Industrial Control Equipment with Revision through July 2005 314.2.3