About this chapter: The International Building Code® contains numerous references to standards promulgated by other organizations that are used to provide requirements for materials and methods of construction. This chapter contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.
AA
Aluminum Association
1400 Crystal Drive, Suite 430
Arlington, VA 22202
ADM—2020
Aluminum Design Manual
ASM 35—00
Aluminum Sheet Metal Work in Building Construction (Fourth Edition)
AAMA
American Architectural Manufacturers Association
1900 E Golf Road, Suite 1250
Schaumburg, IL 60173
711—20
Voluntary Specification for Self Adhering Flashing Used for Installation of Exterior Wall Fenestration Products
714—19
Voluntary Specification for Liquid Applied Flashing Used to Create a Water-resistive Seal around Exterior Wall Openings in Buildings
1402—09
Standard Specifications for Aluminum Siding, Soffit and Fascia
2502—19
Comparative Analysis Procedure for Window and Door Products
AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standard/Specifications for Windows, Doors and Skylights
ACI
American Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331-3439
117—10
Specification for Tolerances for Concrete Construction and Materials
216.1—14
Code Requirements for Determining Fire Resistance of Concrete and Masonry Construction Assemblies
550.5—18
Code Requirements for the Design of Precast Concrete Diaphragms for Earthquake Motions
ITG—7-09
Specification for Tolerances for Precast Concrete
AISC
American Institute of Steel
130 East Randolph Street, Suite 2000
Chicago, IL 60601-6219
ANSI/AISC 341—16
Seismic Provisions for Structural Steel Buildings
ANSI/AISC 358—16/s1—18
Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications, IncludingSupplement No. 1
ANSI/AISC 360—16
Specification for Structural Steel Buildings
AISI
American Iron and Steel Institute
25 Massachusetts Avenue, NW Suite 800
Washington, DC 20001
AISI S100—16 (2020) w/S2—20:
North American Specification for the Design of Cold-Formed Steel Structural Members, 2016 Edition (Reaffirmed 2020), with Supplement 2, 2020 Edition
AISI S202—20
Code of Standard Practice for Cold-formed Steel Framing, 2020
AISI S220—20
North American Standard for Cold-formed Steel Nonstructural Framing
2202.1, 2203.1, 2211.2, Table 2506.2, Table 2507.2
AISI S230—2019
Standard for Cold-formed Steel Framing—Prescriptive Method for One- and Two-family Dwellings, 2019
AISI S240—20
North American Standard for Cold-Formed Steel Structuring Framing, 2020
2202.1, 2203.1, 2211.1, 2211.1.1.1, 2211.1.3.3, Table 2506.2, Table 2507.2, Table 2603.12.1, Table 2603.12.2
AISI S400—20
North American Standard for Seismic Design of Cold-formed Steel Structural Systems, 2020
ALI
Automotive Lift Institute, Inc.
P.O. Box 85
Cortland, NY 13045
ALI ALCTV—2017
Standard for Automotive Lifts—Safety Requirements for Construction, Testing and Validation (ANSI)
Table 3001.3
AMCA
Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004
540—13
Test Method for Louvers Impacted by Wind Borne Debris
ANSI
American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
A13.1—2020
Scheme for the Identification of Piping Systems
A108.1A—17
Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar
A108.1B—17
Installation of Ceramic Tile, Quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex-Portland Mortar
A108.4—09
Installation of Ceramic Tile with Organic Adhesives or Water-cleanable Tile-setting Epoxy Adhesive
A108.5—20
Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex-Portland Cement Mortar
A108.6—99(reaffirmed 2019)
Installation of Ceramic Tile with Chemical-resistant, Water Cleanable Tile-setting and -grouting Epoxy
A108.8—99(reaffirmed 2019)
Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout
A108.9—99(reaffirmed 2019)
Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout
A108.10—17
Installation of Grout in Tilework
A118.1—18
American National Standard Specifications for Dry-set Portland Cement Mortar
A118.3—13
American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy and Water Cleanable Tile-setting Epoxy Adhesive
A118.4—18
American National Standard Specifications for Modified Dry-set Cement Mortar
A118.5—99
American National Standard Specifications for Chemical Resistant Furan Mortar and Grouts for Tile Installation
A118.6—19
American National Standard Specifications for Cement Grouts for Tile Installation
A118.8—99
American National Standard Specifications for Modified Epoxy Emulsion Mortar/Grout
A136.1—20
American National Standard Specifications for the Installation of Ceramic Tile
A137.1—19
American National Standard Specifications for Ceramic Tile
202
A137.3—17
American National Standard Specifications for Gauged Porcelain Tiles and Gauged Porcelain Tile Panel/Slabs
202
Z 97.1—14
Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test
APA
APA - Engineered Wood Association
7011 South 19th Street
Tacoma, WA 98466-7400
ANSI 117—2020
Standard Specification for Structural Glued Laminated Timber of Softwood Species
ANSI/APA A190.1—2017
Structural Glued Laminated Timber
ANSI/APA PRG 320—2019
Standard for Performance-rated Cross-laminated Timber
ANSI/APA PRP 210—2019
Standard for Performance-Rated Engineered Wood Siding
2303.1.5, 2304.7, 2306.3, Table 2306.3(1)
ANSI/APA PRR 410—16
Standard for Performance-Rated Engineered Wood Rim Boards
APA PDS Supplement 1—12
Design and Fabrication of Plywood Curved Panels (revised 2013)
APA PDS Supplement 2—12
Design and Fabrication of Plywood-lumber Beams (revised 2013)
APA PDS Supplement 3—12
Design and Fabrication of Plywood Stressed-skin Panels (revised 2013)
APA PDS Supplement 4—12
Design and Fabrication of Plywood Sandwich Panels (revised 2013)
APA PDS Supplement 5—16
Design and Fabrication of All-plywood Beams (revised 2013)
APA PDS—20
Panel Design Specification
APA R540—19
Builder Tips: Proper Storage and Handling of Glulam Beams
APA S475—20
Glued Laminated Beam Design Tables
APA S560—20
Field Notching and Drilling of Glued Laminated Timber Beams
APA T300—16
Glulam Connection Details
APA X440—17
Product Guide: Glulam
APA X450—18
Glulam in Residential Construction—Building—Construction Guide
ASABE
American Society of Agricultural and
Biological Engineers
2950 Niles Road
St. Joseph, MI 49085
EP 484.3 DEC2017
Diaphragm Design of Metal-clad, Wood-frame Rectangular Buildings
EP 486.3 SEP2017
Shallow-post and Pier Foundation Design
EP 559.1 AUG2010 (R2019)
Design Requirements and Bending Properties for Mechanically Laminated Wood Assemblies
ASCE/SEI
American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191
8—02
Standard Specification for the Design of Cold-formed Stainless Steel Structural Members
19—16
Structural Applications of Steel Cables for Buildings
24—14
Flood Resistant Design and Construction
29—05
Standard Calculation Methods for Structural Fire Protection
32—01
Design and Construction of Frost Protected Shallow Foundations
49—12
Wind Tunnel Testing for Buildings and Other Structures
ASHRAE
ASHRAE
1791 Tullie Circle NE
Atlanta, GA 30329USA
170—2017
Ventilation of Health Care Facilities
ASME
American Society of Mechanical Engineers
Two Park Avenue
New York, NY 10016
A17.1—2019/CSA B44—19
Safety Code for Elevators and Escalators
A17.7—2007/CSA B44—07 (R2017)
Performance-based Safety Code for Elevators and Escalators
Table 3001.3, 3001.5, 3002.5
A18.1—2020
Safety Standard for Platform Lifts and Stairway Chairlifts
1110.9, Table 3001.3
A90.1—2015
Safety Standard for Belt Manlifts
Table 3001.3
B16.18—2018
Cast Copper Alloy Solder Joint Pressure Fittings
B16.22—2018
Wrought Copper and Copper Alloy Solder Joint Pressure Fittings
B20.1—2018
Safety Standard for Conveyors and Related Equipment
Table 3001.3, 3004.3
B31.3—2020
Process Piping
ASSP
American Society of Safety Professionals
520 N. Northwest Highway
Park Ridge, IL 60068
ANSI/ASSE Z359.1—2020
The Fall Protection Code
ASTM
ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken, PA 19428
A6/A6M—2017A
Standard Specification for General Requirements for Rolled Structural Steel Bars, Plates, Shapes and Sheet Piling
A36/A36M—14
Specification for Carbon Structural Steel
A153/A153M—2016A
Specification for Zinc Coating (Hot-dip) on Iron and Steel Hardware
A240/A240M—17
Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications
Table 1507.4.3(1)
A252—2010(2018)
Specification for Welded and Seamless Steel Pipe Piles
A283/A283M—2018
Specification for Low and Intermediate Tensile Strength Carbon Steel Plates
A416/A416M—2017A
Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete
A463/A463M—15
Standard Specification for Steel Sheet, Aluminum-coated, by the Hot-dip Process
A572/A572M—2018
Specification for High-strength Low-alloy Columbium-Vanadium Structural Steel
A588/A588M—15
Specification for High-strength Low-alloy Structural Steel with 50 ksi (345 MPa) Minimum Yield Point with Atmospheric Corrosion Resistance
A615/A615M—15ae1
Specification for Deformed and Plain Carbon-steel Bars for Concrete Reinforcement
A653/A653M—2017
Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron Alloy-coated Galvannealed by the Hot-dip Process
Table 1507.4.3(1), Table 1507.4.3(2), 2304.10.6.1
A690/A690M—13a(2018)
Standard Specification for High-strength Low-alloy Nickel, Copper, Phosphorus Steel H-piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Marine Environments
A706/A706M—2016
Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement
A722/A722M—2018
Specification for High-strength Steel Bars for Prestressed Concrete
A755/A755M—2016E1
Specification for Steel Sheet, Metallic-coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products
Table 1507.4.3(1), Table 1507.4.3(2)
A792/A792M—10(2015)
Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process
Table 1507.4.3(1), Table 1507.4.3(2)
A875/A875M—13
Standard Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the Hot-dip Process
A924/A924M—2017A
Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process
Table 1507.4.3(1)
B42—2015A
Specification for Seamless Copper Pipe, Standard Sizes
B43—15
Specification for Seamless Red Brass Pipe, Standard Sizes
B68/B68M—11
Specification for Seamless Copper Tube, Bright Annealed (Metric)
B88—2016
Specification for Seamless Copper Water Tube
B101—12
Specification for Lead-coated Copper Sheet and Strip for Building Construction
1403.5.3, Table 1507.2.8.2, Table 1507.4.3(1)
B209—14
Specification for Aluminum and Aluminum Alloy Steel and Plate
Table 1507.4.3(1)
B251—2017
Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube
B280—2018
Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service
B370—12
Specification for Copper Sheet and Strip for Building Construction
1403.5.2, Table 1507.2.8.2, Table 1507.4.3(1)
B695—2004(2016)
Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel Strip for Building Construction
C5—2018
Specification for Quicklime for Structural Purposes
2109.2.4.8.7, Table 2507.2
C22/C22M—2015
Specification for Gypsum
Table 2506.2
C27—1998(2018)
Specification for Classification of Fireclay and High-alumina Refractory Brick
C28/C28M—10(2015)
Specification for Gypsum Plasters
Table 2507.2
C31/C31M—2018B
Practice for Making and Curing Concrete Test Specimens in the Field
C33/C33M—2018
Specification for Concrete Aggregates
C35/C35—01(2014)
Specification for Inorganic Aggregates for Use in Gypsum Plaster
Table 2507.2
C55—2017
Specification for Concrete Building Brick
Table 722.3.2
C59/C59M—00(2015)
Specification for Gypsum Casting Plaster and Molding Plaster
Table 2507.2
C61/C61M—00(2015)
Specification for Gypsum Keene's Cement
Table 2507.2
C62—2017
Standard Specification for Building Brick (Solid Masonry Units Made from Clay or Shale)
C67/C67M—2018
Test Methods of Sampling and Testing Brick and Structural Clay Tile
C73—2017
Specification for Calcium Silicate Brick (Sand-lime Brick)
Table 722.3.2
C90—2016A
Specification for Loadbearing Concrete Masonry Units
Table 722.3.2, 1807.1.6.3, 2114.3
C91/C91M—2018
Specification for Masonry Cement
Table 2507.2
C94/C94M—2017A
Specification for Ready-mixed Concrete
C140/C140M—2018
Test Method Sampling and Testing Concrete Masonry Units and Related Units
C141/C141M—14
Standard Specification for Hydrated Hydraulic Lime for Structural Purposes
C150/C150M—2018
Specification for Portland Cement
Table 2507.2
C172/C172M—2017
Practice for Sampling Freshly Mixed Concrete
C199—1984(2016)
Test Method for Pier Test for Refractory Mortars
C206—14
Specification for Finishing Hydrated Lime
2109.2.4.8.7, Table 2507.2
C208—2012(2017)E1
Specification for Cellulosic Fiber Insulating Board
Table 1508.2, 2303.1.6
C216—2017A
Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)
C270—14a
Specification for Mortar for Unit Masonry
C315—2007(2016)
Specification for Clay Flue Liners and Chimney Pots
2111.9, 2113.11.1, Table 2113.16(1)
C317/C317M—2000(2015)
Specification for Gypsum Concrete
C330/C330M—2017A
Specification for Lightweight Aggregates for Structural Concrete
202
C331/C331M—2017
C406/C406M—15
Specification for Roofing Slate
C472—99(2014)
Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum Concrete
Table 2506.2
C473—2017
Test Methods for Physical Testing of Gypsum Panel Products
Table 2506.2
C474—15
Test Methods for Joint Treatment Materials for Gypsum Board Construction
Table 2506.2
C475/C475M—2017
Specification for Joint Compound and Joint Tape for Finishing Gypsum Board
Table 2506.2
C514—04(2014)
Specification for Nails for the Application of Gypsum Board
C516—2008(2014)E1
Specifications for Vermiculite Loose Fill Thermal Insulation
C547—2017
Specification for Mineral Fiber Pipe Insulation
C549—06(2012)
Specification for Perlite Loose Fill Insulation
C552—2017E1
Standard Specification for Cellular Glass Thermal Insulation
Table 1508.2
C557—2003(2017)
Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing
Table 2506.2, 2508.4
C578—2018
Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation
Table 1508.2, 2603.10, Table 2603.12.1, Table 2603.12.2, Table 2603.13.1, Table 2603.13.2
C587—2004(2018)
Specification for Gypsum Veneer Plaster
Table 2507.2
C595/C595M—2018
Specification for Blended Hydraulic Cements
Table 2507.2
C631—09(2014)
Specification for Bonding Compounds for Interior Gypsum Plastering
Table 2507.2
C635/C635M—2017
Specification for the Manufacture, Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings
C636/C636M—13
Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels
C652—2017A
Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale)
C726—2017
Standard Specification for Mineral Wool Roof Insulation Board
Table 1508.2
C728—2017A
Standard Specification for Perlite Thermal Insulation Board
Table 1508.2
C744—2016
Specification for Prefaced Concrete and Calcium Silicate Masonry Units
Table 722.3.2
C754—2018
Specification for Installation of Steel Framing Members to Receive Screw-attached Gypsum Panel Products
Table 2508.1, Table 2511.1.1
C836/C836M—2018
Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course
C840—2018A
Specification for Application and Finishing of Gypsum Board
Table 2508.1, 2509.2
C841—2003(2018)
Specification for Installation of Interior Lathing and Furring
Table 2508.1, Table 2511.1.1
C842—05(2015)
Specification for Application of Interior Gypsum Plaster
Table 2511.1.1, 2511.3, 2511.4
C843—2017
Specification for Application of Gypsum Veneer Plaster
Table 2511.1.1
C844—2015
Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster
Table 2508.1
C847—2018
Specification for Metal Lath
Table 2507.2
C887—13
Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar
C897—15
Specification for Aggregate for Job-mixed Portland Cement-based Plaster
Table 2507.2
C920—2018
Standard for Specification for Elastomeric Joint Sealants
703.7, Table 2506.2
C926—2018B
Specification for Application of Portland Cement-based Plaster
C932—06(2013)
Specification for Surface-applied Bonding Compounds for Exterior Plastering
Table 2507.2
C933—2018
Specification for Welded Wire Lath
Table 2507.2
C946—2018
Specification for Construction of Dry-stacked, Surface-bonded Walls
C954—2018
Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 inch (0.84 mm) to 0.112 inch (2.84 mm) in Thickness
Table 2506.2, Table 2507.2
C956—04(2015)
Specification for Installation of Cast-in-place Reinforced Gypsum Concrete
C957/C957M—2017
Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane with Integral Wearing Surface
C1002—2018
Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs
722.7.2.2, Table 2506.2, Table 2507.2
C1007—11a(2015)
Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories
Table 2508.1, Table 2511.1.1
C1029—15
Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation
C1032—2018
Specification for Woven Wire Plaster Base
Table 2507.2
C1047—2014a
Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base
Table 2506.2, Table 2507.2
C1063—2018B
Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster
2109.2.4.8.5, 2510.3, Table 2511.1.1, 2512.1.1
C1088—2018
Specification for Thin Veneer Brick Units Made from Clay or Shale
C1157/C1157M—2017
Standard Performance Specification for Hydraulic Cement
Table 2507.2
C1167—2011(2017)
Specification for Clay Roof Tiles
C1177/C1177M—2017
Specification for Glass Mat Gypsum Substrate for Use as Sheathing
Table 1508.2, Table 2506.2
C1178/C1178M—2018
Specification for Coated Mat Water-resistant Gypsum Backing Panel
Table 2506.2, Table 2509.2
C1186—2008(2016)
Specification for Flat Fiber Cement Sheets
C1261—2013(2017)E1
Specification for Firebox Brick for Residential Fireplaces
C1278/C1278M—2017
Specification for Fiber-reinforced Gypsum Panel
Table 1508.2, Table 2506.2
C1280—13a
Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing
Table 2508.1, 2508.2
C1283—2015
Practice for Installing Clay Flue Lining
C1288—2017
Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets
Table 2509.2
C1289—2018
Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
Table 1508.2, 2603.10, Table 2603.12.1, Table 2603.12.2
C1313/C1313M—13
Standard Specification for Sheet Radiant Barriers for Building Construction Applications
C1325—2018
Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Backer Units
Table 2509.2
C1328/C1328M—12
Specification for Plastic (Stucco Cement)
Table 2507.2
C1364—2017
Standard Specification for Architectural Cast Stone
C1372—17
Standard Specification for Dry-Cast Segmental Retaining Wall Units
C1396/C1396M—2017
Specification for Gypsum Board
Figure 722.5.1(2), Figure 722.5.1(3), Table 2506.2
C1492—2003(2016)
Standard Specification for Concrete Roof Tile
C1568—08(2013)
Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles (Mechanical Uplift Resistance Method)
C1569—03(2016)
Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles (Wind Tunnel Method)
C1570—03(2016)
Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles (Air Permeability Method)
C1600/C1600M—2017
Standard Specification for Rapid Hardening Hydraulic Cement
Table 2507.2
C1629/C1629M—2018A
Standard Classification for Abuse-resistant Nondecorated Interior Gypsum Panel Products and Fiber-reinforced Cement Panels
C1658/C1658M—2018
Standard Specification for Glass Mat Gypsum Panels
Table 2506.2
C1670/C1670M—2018
Standard Specification for Adhered Manufactured Stone Masonry Veneer Units
C1707—18 
Standard Specification for Pozzolanic Hydraulic Lime for Structural Purposes
C1766—2015
Standard Specification for Factory-laminated Gypsum Panel Products
Table 2506.2
C1788—14
Standard Specification for Non Metallic Plaster Bases (Lath) Used with Portland Cement Based Plaster in Vertical WallApplications
D25—2012(2017)
Specification for Round Timber Piles
D41/D41M—2011(2016)
Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing
Table 1507.10.2
D43/D43M—2000(2018)
Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing
Table 1507.10.2
D56—2016A
Test Method for Flash Point by Tag Closed Cup Tester
202
D86—2017
Test Method for Distillation of Petroleum Products and Liquid Fuels at Atmospheric Pressure
202
D92—2018
Test Method for Flash and Fire Points by Cleveland Open Cup Tester
202
D93—2018
Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
202
D226/D226M—2017
Specification for Asphalt-saturated Organic Felt Used in Roofing and Waterproofing
D227/D227M—2003(2018)
Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing
Table 1507.10.2
D312/D312M—2016M
Specification for Asphalt Used in Roofing
Table 1507.10.2
D422—63(2007)e2
Test Method for Particle-size Analysis of Soils
D448—2012(2017)
Standard Classification for Sizes of Aggregate for Road and Bridge Construction
D450/D450M—2017(2018)
Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing
Table 1507.10.2
D635—14
Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position
D1143/D1143M—2007(2013)E1
Test Methods for Deep Foundations Under Static Axial Compressive Load
D1227—13
Specification for Emulsified Asphalt Used as a Protective Coating for Roofing
Table 1507.10.2
D1557—12e1
Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort [56,000 ft-lb/ft3(2,700 kN m/m3)]
D1863/D1863M—2005(2018)
Specification for Mineral Aggregate Used on Built-up Roofs
Table 1504.9, Table 1507.10.2
D1929—16
Standard Test Method for Determining Ignition Temperature of Plastics
D1970/D1970M—2017A
Specification for Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection
D2178/D2178M—15A
Specification for Asphalt Glass Felt Used in Roofing and Waterproofing
Table 1507.10.2
D2487—2017
Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)
D2626/D2626M—04(2012)e1
Specification for Asphalt Saturated and Coated Organic Felt Base Sheet Used in Roofing
Table 1507.1.1(1), 1507.3.3, Table 1507.10.2
D2822/D2822M—2005(2011)
Specification for Asphalt Roof Cement, Asbestos Containing
Table 1507.10.2
D2823/D2823M—05(2011)e1
Specification for Asphalt Roof Coatings, Asbestos Containing
Table 1507.10.2
D2824/D2824M—2018
Standard Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered and Fibered without Asbestos
Table 1507.10.2
D2843—16
Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics
D2859—2016
Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials
D2898—2010(2017)
Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing
D3019/D3019M—2017
Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered
Table 1507.10.2
D3161/D3161M—2016A
Test Method for Wind Resistance of Steep Slope Roofing Products (Fan Induced Method)
D3200—1974(2017)
Standard Specification and Test Method for Establishing Recommended Design Stresses for Round Timber Construction Poles
D3201/D3201M—13
Test Method for Hygroscopic Properties of Fire-retardant-treated Wood and Wood-based Products
D3278—96(2011)
Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus
202
D3462/D3462M—2016
Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules
D3468/D3468M—99(2013)e1
Specification for Liquid-applied Neoprene and Chlorosulfonated Polyethylene Used in Roofing and Waterproofing
D3498—03(2011)
Standard Specification for Adhesives for Field-Gluing Plywood to Lumber Framing for Floor Systems
D3679—2017
Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding
D3689/D3698M—07(2013)e1
Test Methods for Deep Foundations under Static Axial Tensile Load
D3737—2018E1
Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam)
D3746/D3746M—1985(2015)E1
Test Method for Impact Resistance of Bituminous Roofing Systems
D3747—79(2007)
Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation
Table 1507.10.2
D3909/D3909M—14
Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules
1507.2.8.2, 1507.6.5, Table 1507.10.2
D3957—2009(2015)
Standard Practices for Establishing Stress Grades for Structural Members Used in Log Buildings
D4022/D4022M—07(2012)e1
Specification for Coal Tar Roof Cement, Asbestos Containing
Table 1507.10.2
D4272—15
Test Method for Total Energy Impact of Plastic Films by Dart Drop
D4318—2017E1
Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils
D4434/D4434M—2015
Specification for Poly (Vinyl Chloride) Sheet Roofing
Table 1507.12.2
D4479/D4479M—2007(2018)
Specification for Asphalt Roof Coatings—Asbestos-free
Table 1507.10.2
D4586/D4586M—2007(2018)
Specification for Asphalt Roof Cement—Asbestos-free
Table 1507.10.2
D4601/D4601M—04(2012)e1
Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing
Table 1507.10.2, 1507.11.2.1
D4637/D4637M—2015
Specification for EPDM Sheet Used in Single-ply Roof Membrane
Table 1507.12.2
D4829—11
Test Method for Expansion Index of Soils
D4869/D4869M—2016A
Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing
D4897/D4897M—2016
Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing
Table 1507.10.2
D4945—2017
Test Method for High-strain Dynamic Testing of Deep Foundations
D4990—97a(2013)
Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing
Table 1507.10.2
D5019—07a
Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane
Table 1507.12.2
D5055—2016
Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists
D5456—2018
Specification for Evaluation of Structural Composite Lumber Products
D5516—2018
Test Method of Evaluating the Flexural Properties of Fire-retardant Treated Softwood Plywood Exposed to Elevated Temperatures
D5643/D5643M—2006(2018)
Specification for Coal Tar Roof Cement, Asbestos-free
Table 1507.10.2
D5664—2017
Standard Test Method for Evaluating the Effects of Fire-retardant Treatment and Elevated Temperatures on Strength Properties of Fire-retardant Treated Lumber
D5665/D5665M—99a(2014)e1
Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing
Table 1507.10.2
D5726—98(2013)
Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing
Table 1507.10.2
D5882—16
Standard Test Method for Low Strain Impact Integrity Testing of Deep Foundations
D6083/D6083M—2018
Specification for Liquid Applied Acrylic Coating Used in Roofing
Table 1507.10.2, Table 1507.13.3
D6162/D6162M—2016
Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements
D6163/D6163M—2016
Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements
D6164/D6164M—2016
Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Metal Materials Using Polyester Reinforcements
D6222/D6222M—2016
Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements
D6223/D6223M—2016
Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements
D6298—2016
Specification for Fiberglass Reinforced Styrene-butadiene-styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface
D6305—08(2015)e1
Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing
D6380/D6380M—2003(2018)
Standard Specification for Asphalt Roll Roofing (Organic) Felt
D6464—2003A(2017)
Standard Specification for Expandable Foam Adhesives for Fastening Gypsum Wallboard to Wood Framing
Table 2506.2, 2508.4
D6509/D6509M—2016
Standard Specification for Atactic Polypropylene (APP) Modified Bituminous Base Sheet Materials Using Glass Fiber Reinforcements
D6694/D6694M—15
Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing Systems
Table 1507.13.3
D6754/D6754M—2015
Standard Specification for Ketone Ethylene Ester Based Sheet Roofing
Table 1507.12.2
D6757—2018
Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep Slope Roofing
D6760—16
Standard Test Method for Integrity Testing of Concrete Deep Foundations by Ultrasonic Crosshole Testing
D6841—2016
Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant Treated Lumber
D6878/D6878M—2017
Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing
Table 1507.12.2
D6947/D6947M—2016
Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System
Table 1507.13.3
D7032—2017
Standard Specification for Establishing Performance Ratings for Wood, Plastic Composite Deck Boards and Guardrail Systems (Guards or Rails)
D7147—2011(2018)
Specification for Testing and Establishing Allowable Loads of Joist Hangers
D7158/D7158M—2019
Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method)
D7254—2017
Standard Specification for Polypropylene (PP) Siding
D7425/D7425M—13
Standard Specification for Spray Polyurethane Foam Used for Roofing Applications
D7655/D7655M—2012(2017)
Standard Classification for Size of Aggregate Used as Ballast for Roof Membrane Systems
D7672—14E1
Standard Specification for Evaluating Structural Capacities of Rim Board Products and Assemblies
D7949—14
Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations
E84—2018B
Standard Test Methods for Surface Burning Characteristics of Building Materials
E90—2009(2016)
Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
E96/E96M—2016
Standard Test Methods for Water Vapor Transmission of Materials
E108—2017
Standard Test Methods for Fire Tests of Roof Coverings
E119—2018B
Standard Test Methods for Fire Tests of Building Construction and Materials
E136—2019
Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C
E283—04(2012)
Standard Test Method for Determining Rate of Air Leakage through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences across the Specimen
202
E330/E330M—14
Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
E331—2000(2016)
Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference
E336—19a
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
E492—2009(2016)E1
Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-ceiling Assemblies Using the Tapping Machine
E605/E605M—93(2015)e1
Test Method for Thickness and Density of Sprayed Fire-resistive Material (SFRM) Applied to Structural Members
E648—2017A
Standard Test Method for Critical Radiant Flux of Floor-covering Systems Using a Radiant Heat Energy Source
E681—09(2015)
Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases
202
E736/E736M—2017
Test Method for Cohesion/Adhesion of Sprayed Fire-resistive Materials Applied to Structural Members
E814—2013A(2017)
Test Method for Fire Tests of Penetration Firestop Systems
E970—2017
Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
E1007—19
Test Method f or Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
E1300—2016
Practice for Determining Load Resistance of Glass in Buildings
E1354—2017
Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter
E1592—2005(2017)
Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference
E1602—2003(2017)
Guide for Construction of Solid Fuel-burning Masonry Heaters
E1886—2013A
Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
E1966—15
Standard Test Method for Fire-resistive Joint Systems
E1996—2017
Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
E2072—14
Standard Specification for Photoluminescent (Phosphorescent) Safety Markings
E2174—2018
Standard Practice for On-site Inspection of Installed Fire Stops
E2178—13
Standard Test Method for Air Permeance of Building Materials
202
E2273—2018
Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies
E2307—15BE1
Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using the Intermediate-scale, Multistory Test Apparatus
E2353—2016
Standard Test Methods for Performance of Glazing in Permanent Railing Systems, Guards and Balustrades
E2392 / E2392M—10(2016) 
Standard Guide for Design of Earthen Wall Building Systems
E2393—10a(2015)
Standard Practice for On-site Inspection of Installed Fire Resistive Joint Systems and Perimeter Fire Barriers
E2404—2017
Practice for Specimen Preparation and Mounting of Textile, Paper or Polymeric (Including Vinyl) and Wood Wall or Ceiling Coverings, Facing and Veneers to Assess Surface Burning Characteristics
E2556/E2556M—2010(2016)
Standard Specification for Vapor Permeable Flexible Sheet Water-resistive Barriers Intended for Mechanical Attachment
E2568—2017A
Standard Specification for PB Exterior Insulation and Finish Systems
E2570/E2570M—07(2014)e1
Standard Test Method for Evaluating Water-resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) for EIFS with Drainage
E2573—2017
Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface Burning Characteristics
E2579—2015
Standard Practice for Specimen Preparation and Mounting of Wood Products to Assess Surface Burning Characteristics
E2599—2018
Standard Practice for Specimen Preparation and Mounting of Reflective Insulation, Radiant Barrier and Vinyl Stretch Ceiling Materials for Building Applications to Assess Surface Burning Characteristics
E2634—2018
Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems
E2652—16
Standard Test Method for Behavior of Materials in a Tube Furnace with a Cone-shaped Airflow Stabilizer at 750oC
E2751/E2751M—2017A
Practice for Design and Performance of Supported Laminated Glass Walkways
E2925—17
Standard Specification for Manufactured Polymeric Drainage and Ventilation Materials Used to Provide a Rainscreen Function
F547—2017
Terminology of Nails for Use with Wood and Wood-base Materials
Table 2506.2
F1667—2018
Specification for Driven Fasteners: Nails, Spikes and Staples
Table 721.1(2), Table 721.1(3), 1507.2.5, 1507.16.5, 2303.6, Table 2304.10.2, 2304.10.6 , Table 2506.2, Table 2603.13.1, Table 2603.13.2
F2006—17
Standard/Safety Specification for Window Fall Prevention Devices for Nonemergency Escape (Egress) and Rescue (Ingress) Windows
F2090—17
Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms
F2200—2017
Standard Specification for Automated Vehicular Gate Construction
G152—13
Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials
G154—2016A
Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials
G155—13
Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic Materials
AWC
American Wood Council
222 Catoctin Circle SE, Suite 201
Leesburg, VA 20175
ANSI/AWC NDS—2018
National Design Specification (NDS) for Wood Construction—with 2018 NDS Supplement
202, 722.1, Table 1604.3, 1809.12, 1810.3.2.4, Table 1810.3.2.6, 1905.1.8, 2304.13, 2306.1, Table 2306.2(1), Table 2306.2(2), Table 2306.3(1), Table 2306.3(2), 2307.1, Table 2603.13.2
ANSI/AWC PWF—2021
Permanent Wood Foundation Design Specification
ANSI/AWC SDPWS—2021
Special Design Provisions for Wind and Seismic
ANSI/AWC WFCM—2018
Wood Frame Construction Manual for One- and Two-Family Dwellings
AWC STJR—2021
Span Tables for Joists and Rafters
AWC WCD No. 4—2003
Wood Construction Data—Plank and Beam Framing for Residential Buildings
AWCI
Association of the Wall and Ceiling Industry
513 West Broad Street, Suite 210
Falls Church, VA 22046
12-B—14
Technical Manual 12B, Third Edition; Standard Practice for the Testing and Inspection of Field Applied Thin Film Intumescent Fire-resistive Materials; an Annotated Guide
AWPA
American Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
C1—03
All Timber Products—Preservative Treatment by Pressure Processes
M4—15
Standard for the Care of Preservative-treated Wood Products
U1—20
USE CATEGORY SYSTEM: User Specification for Treated Wood Except Commodity Specification H
AWS
American Welding Society
8669 NW 36 Street, #130
Miami, FL 33166-6672
D1.4/D1.4M—2018
Structural Welding Code—Steel Reinforcing Bars 
BHMA
Builders Hardware Manufacturers' Association
355 Lexington Avenue, 15th Floor
New York, NY 10017
A 156.10—2017
Power Operated Pedestrian Doors
A 156.19—2019
Standard for Power Assist and Low Energy Power Operated Doors
A 156.27—2019
Power and Manual Operated Revolving Pedestrian Doors
A 156.38—2019
Low Energy Power Operated Sliding and Folding Doors
CEN
European Committee for Standardization (CEN)
Rue de la Science 23
Brussels, Belgium 1000
BS EN 15250—2007
Slow Heat Release Appliances Fired by Solid Fuel Requirements and Test Methods
EN 1081—98
Resilient Floor Coverings—Determination of the Electrical Resistance
CPA
Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA  20176
ANSI A135.4—2012
Basic Hardboard
ANSI A135.5—2012
Prefinished Hardboard Paneling
ANSI A135.6—2012
Engineered Wood Siding
ANSI A208.1—2016
CPSC
Consumer Product Safety Commission
4330 East/West Highway
Bethesda, MD 20814
16 CFR Part 1201 (2002)
Safety Standard for Architectural Glazing Material
16 CFR Part 1209 (2002)
Interim Safety Standard for Cellulose Insulation
16 CFR Part 1404 (2002)
Cellulose Insulation
16 CFR Part 1500 (2009)
Hazardous Substances and Articles; Administration and Enforcement Regulations
202
16 CFR Part 1500.44 (2009)
Method for Determining Extremely Flammable and Flammable Solids
202
16 CFR Part 1507 (2002)
Fireworks Devices
202
16 CFR Part 1630 (2007)
Standard for the Surface Flammability of Carpets and Rugs
CSA
Canadian Standards Association
8501 East Pleasant Valley Road
Cleveland, OH 44131
AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standard/Specifications for Windows, Doors and Unit Skylights
ASME A17.1—2019/CSA B44-—2019
Safety Code for Elevators and Escalators
ASME A17.7—2007/CSA B44.7—07(R2017)
Performance-based Safety Code for Elevators and Escalators
Table 3001.3, 3001.5, 3002.5
CSSB
Cedar Shake & Shingle Bureau
P. O. Box 1178
Sumas, WA 98295-1178
CSSB—97
Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau
Table 1507.8.5, Table 1507.9.6
DASMA
Door & Access Systems Manufacturers
Association International
1300 Sumner Avenue
Cleveland, OH 44115
ANSI/DASMA 107—2017
Room Fire Test Standard for Garage Doors Using Foam Plastic Insulation
ANSI/DASMA 108—2017
Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference
ANSI/DASMA 115—2017
Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure
DHA
Decorative Hardwoods Association
42777 Trade West Dr
Sterling, VA 20166
ANSI/HPVA HP-1—2016
American National Standard for Hardwood and Decorative Plywood
DOC
U.S. Department of Commerce
National Institute of Standards and
Technology 100 Bureau Drive
Gaithersburg, MD 20899
PS 1—19
Structural Plywood
2303.1.5, 2304.7, Table 2304.8(4), Table 2304.8(5), Table 2306.2(1), Table 2306.2(2)
PS 2—18
Performance Standard for Wood-based Structural-use Panels
2303.1.5, 2304.7, Table 2304.8(5), Table 2306.2(1), Table 2306.2(2)
PS 20—05
American Softwood Lumber Standard
DOL
U.S. Department of Labor
Occupational Safety and Health Administration
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20210
29 CFR Part 1910.1000 (2015)
Air Contaminants
202
DOTn
U.S. Department of Transportation
Office of Hazardous Material Safety
1200 New Jersey Avenue,
SE East Building, 2nd Floor
Washington, DC 20590
49 CFR 173.192—2011
Packaging for Certain Toxic Gases in Hazard Zone A
Table 415.6.5
49 CFR Parts 100—185—2015
202
49 CFR Parts 173—178—2015
Specification of Transportation of Explosive and Other Dangerous Articles, UN 0335, UN 0336 Shipping Containers
202
49 CFR Parts 173.137—(2009)
Shippers—General Requirements for Shipments and Packaging—Class 8—Assignment of Packing Group
202
EN
European Committee for Standardization
Rue de la Science 23 B
Brussels, Belgium Belgium 1040 
EN 459-1—15 
Building Lime. Definitions, Specifications and Conformity Criteria
FEMA
Federal Emergency Management Agency
500 C Street S.W.
Washington, DC 20472
FEMA-TB-11—01
Crawlspace Construction for Buildings Located in Special Flood Hazard Areas
FM
FM Approvals
Headquarters Office
1151 Boston-Providence Turnpike
P.O. Box 9102
Norwood, MA 02062
4430—2012
Approval Standard for Heat and Smoke Vents
4450—(1989)
Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 1992
4470—2016
Approval Standard for Single-ply Polymer-modified Bitumen Sheet, Built-up Roof (BUR) and Liquid Applied Roof Assemblies for Use in Class 1 and Noncombustible Roof Deck Construction
4474—2011
American National Standard for Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures
4880—2017
American National Standard for Evaluating the Fire Performance Insulated Building Panel Assemblies and Interior Finish Materials
GA
Gypsum Association
962 Wayne Avenue, Suite 620
Silver Spring, MD 20910
GA 216—2018
Application and Finishing of Gypsum Panel Products
Table 2508.1, 2509.2
GA 600—2018
Fire-resistance and Sound Control Design Manual, 22nd Edition
ICC
International Code Council, Inc.
500 New Jersey Ave NW 6th Floor
Washington, DC 20001
ICC 400—17
Standard on Design and Construction of Log Structures
ICC 500—2020
ICC/NSSA Standard for the Design and Construction of Storm Shelters
ICC 600—2020
Standard for Residential Construction in High-wind Regions
ICC 900/SRCC 300—2020
Solar Thermal System Standard
ICC 901/SRCC 100—2020
Solar Thermal Collector Standard
ICC 1100—18
Standard for Spray-applied Foam Plastic Insulation
IECC—21
International Energy Conservation Code®
IFC—21
101.4.5, 102.6, 102.6.2, 201.3, 202, 307.1, Table 307.1(1), Table 307.1(2), 307.1.1, 403.4.5, 404.2, 406.2.9, 406.6.4.4, 406.7, 406.8, 407.4, 410.2.6, 411.1, 412.1, 412.5.1, 413.1, 414.1.1, 414.1.2, 414.1.2.1, 414.2, Table 414.2.5(1), Table 414.2.5(2), 414.2.5.1, 414.2.5.2, 414.2.5.3, 414.3, 414.5, 414.5.1, Table 414.5.1, 414.5.2, 414.5.3, 414.6, 415.2, 415.6.1, 415.6.2, 415.6.3, 415.6.4, 415.6.4.1, 415.6.4.4, Table 415.6.5, 415.8.2, 415.9, 415.9.1, 415.9.1.3, 415.9.1.4, 415.9.1.6, 415.9.1.7, 415.9.1.8, 415.9.2, 415.9.3, 415.10, 415.11, 415.11.1.7, 415.11.5, 415.11.8.2, 415.11.10.3, 415.11.11.1, 416.1, 416.2.3, 416.4, 419.1, 422.3.1, 426.1, 426.1.4, 427.1, 427.2.3, 428.1, 428.2, 428.3, Table 504.3, Table 504.4, Table 506.2, 507.4, 507.8.1.1.1, 507.8.1.1.2, 507.8.1.1.3, Table 509.1, 705.8.1, 707.1, 707.4, Table 716.1(2), 716.2.5.4.1, 716.3.2.1.1.1, 806.3, 901.2, 901.3, 901.5, 901.6.3, 901.6.4, 903.2.7.1, Table 903.2.11.6, 903.2.12, 903.5, 904.2.2, 904.11.3, 905.1, 905.3.6, 905.3.7, 906.1, Table 906.1, 906.4, 907.1.1, 907.2.5, 907.2.6, 907.2.8, 907.2.13.2, 907.2.15, 907.2.16, 907.2.23, 907.5.2.2, 907.6.6, 907.6.6.3, 907.8, 909.6.3, 909.12.1, 909.19, 909.20, 910.2.2, 910.5, 912.4.3, 915.1, 915.6, 916.7, 916.11, 918.1, 1002.1, 1002.2, 1010.2.14, 1202.5.2, 1202.6, 1507.15, 1512.1, Table 1604.5, 2603.4.1.12, 2701.1, 2702.1.3, 2702.2.3, 2702.2.7, 2702.2.10, 2702.2.13, 2702.2.15, 2702.4, 3003.3, 3008.1.3, 3102.1, 3102.8.3, 3103.1, 3111.1.2, 3111.2, 3111.3, 3111.3.4, 3111.3.5, 3302.3, 3303.7, 3309.2
IPMC—21
International Property Maintenance Code®
IPSDC—21
International Private Sewage Disposal Code®
IRC—21
International Residential Code®
ISPSC—21
International Swimming Pool and Spa Code®
IWUIC—21
International Wildland-Urban Interface Code®
SBCCI SSTD 11—97
Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles
ISO
International Organization for Standardization
Chemin de Blandonnet 8 CP 401 1214 Vernier
Geneva, Switzerland
ISO 668—2013
Series 1 Freight Containers—Classifications, Dimensions and Ratings
Table 3115.8.5.3
ISO 1496-1—2013
Series 1 Freight Containers—Specification and Testing - Part 1: General Cargo Containers for General Purposes
3115.8, Table 3115.8.5.3
ISO 6346—1995
Freight Containers—Code, Identification and Marking with Amendment 3 - 2012
ISO 8115—86
Cotton Bales—Dimensions and Density
Table 307.1(1), Table 415.11.1.1.1
ISO 8336—09
Fiber-cement Flat Sheets—Product Specification and Test Methods
1403.10, 1404.16.1, 1404.16.2, Table 2509.2
MHI
Material Handling Institute
8720 Red Oak Blvd. Suite 201
Charlotte, NC 28217
ANSI MH29.1—2012
Safety Requirements for Industrial Scissors Lifts
TABLE 3001.3
ANSI/MH16.1—12
Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks
TABLE 1705.13.7
NAAMM
National Association of Architectural
Metal Manufacturers
800 Roosevelt Road, Bldg. C, Suite 312
Glen Ellyn, IL 60137
FP 1001—2007
Guide Specifications for Design of Metal Flag Poles
NCMA
National Concrete Masonry Association
13750 Sunrise Valley
Herndon, VA 20171
TEK 5—8B(2005)
NFPA
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
04—21
Standard for Integrated Fire Protection and Life Safety System Testing
10—2018
Standard for Portable Fire Extinguishers
906.2, Table 906.3(1), Table 906.3(2), 906.3.2, 906.3.4
11—16
Standard for Low-, Medium, and High Expansion Foam
12A—18
Standard on Halon 1301 Fire Extinguishing Systems
13—19
Standard for Installation of Sprinkler Systems
13D—19
Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes
13R—19
Standard for the Installation of Sprinkler Systems in Low-rise Residential Occupancies
14—19
Standard for the Installation of Standpipe and Hose System
16—19
Standard for the Installation of Foam-water Sprinkler and Foam-water Spray Systems
17—2021
Standard for Dry Chemical Extinguishing Systems
17A—2021
Standard for Wet Chemical Extinguishing Systems
20—19
Standard for the Installation of Stationary Pumps for Fire Protection
30A—21
Code for Motor Fuel Dispensing Facilities and Repair Garages
31—20
Standard for the Installation of Oil-burning Equipment
32—16
Standard for Dry Cleaning Facilities
40—19
Standard for the Storage and Handling of Cellulose Nitrate Film
45—19
Standard on Fire Protection Laboratories Using Chemicals
58—20
Liquefied Petroleum Gas Code
61—20
Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Product Facilities
82—19
Standard on Incinerators and Waste and Linen Handling Systems and Equipment
85—19
Boiler and Combustion System Hazards Code
92—18
Standard for Smoke Control Systems
99—21
Health Care Facilities Code
101—21
Life Safety Code
105—19
Standard for Smoke Door Assemblies and Other Opening Protectives
110—19
Standard for Emergency and Standby Power Systems
111—19
Standard on Stored Electrical Energy Emergency and Standby Power Systems
120—20
Standard for Fire Prevention and Control in Coal Mines
170—18
Standard for Fire Safety and Emergency Symbols
211—19
Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances
221—21
Standard for High Challenge Fire Walls, Fire Walls and Fire Barrier Walls
252—17
Standard Methods of Fire Tests of Door Assemblies
253—19
Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source
257—17
Standard for Fire Test for Window and Glass Block Assemblies
259—18
Standard Test Method for Potential Heat of Building Materials
265—19
Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile or Expanded Vinyl Wall Coverings on Full Height Panels and Walls
268—19
Standard Test Method for Determining Ignitability of Exterior Wall Assemblies Using a Radiant Heat Energy Source
275—17
Standard Method of Fire Tests for the Evaluation of Thermal Barriers
276—19
Standard Method of Fire Tests for Determining the Heat Release Rate of Roofing Assemblies with Combustible Above-deck Roofing Components
285—19
Standard Fire Test Method for the Evaluation of Fire Propagation Characteristics of Exterior Nonload-bearing Wall Assemblies Containing Combustible Components
286—15
Standard Methods of Fire Test for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
288—17
Standard Methods of Fire Tests of Horizontal Fire Door Assemblies Installed in Horizontal in Fire-resistance-rated Floor Systems
289—19
Standard Method of Fire Test for Individual Fuel Packages
409—16
Standard for Aircraft Hangars
418—16
Standard for Heliports
484—19
Standard for Combustible Metals
652—19
Standard on the Fundamentals of Combustible Dust
654—20
Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids
655—17
Standard for the Prevention of Sulfur Fires and Explosions
664—20
Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities
701—19
Standard Methods of Fire Tests for Flame Propagation of Textiles and Films
704—17
Standard System for the Identification of the Hazards of Materials for Emergency Response
202, 415.5.2
720—15
Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment
750—19
Standard on Water Mist Fire Protection Systems
1124—17
Code for the Manufacture, Transportation and Storage of Fireworks and Pyrotechnic Articles
2001—18
Standard on Clean Agent Fire Extinguishing Systems
2010—20
Standard for Fixed Aerosol Fire-extinguishing Systems
PCI
Precast Prestressed Concrete Institute
8770 West Bryn Mawr, Suite 1150
Chicago, IL 60631-3517
PCI 124—18
 Specification for Fire Resistance of Precast Prestressed Concrete
PCI 128—19
Specification for Glass Fiber Reinforced Concrete Panels
PTI
Post-Tensioning Institute
38800 Country Club Drive
Farmington Hills, MI 48331
PTI DC—10.5-19
Standard Requirements for Design and Analysis of Shallow Post-Tensioned Concrete Foundations on Expansive and Stable Soils
RMI
Rack Manufacturers Institute
8720 Red Oak Boulevard, Suite 201
Charlotte, NC 28217
ANSI/MH16.1—12
Specification for Design, Testing and Utilization of Industrial Steel Storage Racks
ANSI/MH16.3—16
Specification for the Design, Testing and Utilization of Industrial Steel Cantilevered Storage Racks
SBCA
Structural Building Components Association
6300 Enterprise Lane
Madison, WI 53719
ANSI/FS 100—12(R2018)
Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing Used in Exterior Wall Covering Assemblies
SDI
Steel Deck Institute
2661 Clearview Road #3
Allison Park, PA 15101
SDI NC—2017
Standard for Noncomposite Steel Floor Deck
SDI RD—2017
Standard for Steel Roof Deck
SDI-C—2017
Standard for Composite Steel Floor Deck—Slabs
SDI-QA/QC—2017
Standard for Quality Control and Quality Assurance for Installation of Steel Deck
SJI
Steel Joist Institute
140 Evans Street, Suite 203
Florence, SC 29501
SJI 100—20
45th Edition Standard Specifications, Load Tables and Weight Tables for K-Series, LH-Series, DLH-Series and Joist Girders
SJI 200—15
2nd Edition Standard Specifications, Weight Tables and Bridging Tables for CJ-Series Composite Steel Joists
SPRI
Single-Ply Roofing Institute
465 Waverly Oaks Road, Suite 421
Waltham, MA 02452
ANSI/SPRI GT-1—2016
Test Standard for Gutter Systems
ANSI/SPRI RP-4—19
Wind Design Guide for Ballasted Single-ply Roofing Systems
ANSI/SPRI VF-1—17
External Fire Design Standard for Vegetative Roofs
ANSI/SPRI/FM 4435-ES-1—17
Wind Test Design Standard for Edge Systems Used with Low Slope Roofing Systems
SRCC
Solar Rating & Certification Corporation
400 High Point Drive, Suite 400
Cocoa, FL 32926
ICC 900/SRCC 300—2020
Solar Thermal System Standard
ICC 901/SRCC 100—2020
Solar Thermal Collector Standard
TIA
Telecommunications Industry Association
1320 N. Courthouse Road #200
Arlington, VA 22201
ANSI/TIA 222-H—2017
Structural Standard for Antenna Supporting Structures, Antennas and Small Wind Turbine Support Structures
TMS
The Masonry Society
105 South Sunset Street, Suite Q
Longmont, CO 80501-6172
216—2014
Standard Method for Determining Fire Resistance of Concrete and Masonry Construction Assemblies
302—2018
Standard Method for Determining the Sound Transmission Class Rating for Masonry Walls
403—2017
Direct Design Handbook for Masonry Structures
404—2016
Standard for the Design of Architectural Cast Stone
504—2016
Standard for the Fabrication of Architectural Cast Stone
602—2016
Specification for Masonry Structures
604—2016
Standard for the Installation of Architectural Cast Stone
TPI
Truss Plate Institute
2670 Crain Highway, Suite 203
Waldorf, MD 20601
TPI 1—2014
National Design Standard for Metal-plate-connected Wood Truss Construction
UL
UL LLC
333 Pfingsten Road
Northbrook, IL 60062
9—2009
Fire Tests of Window Assemblies—with Revisions through February 2015
10A—2009
Tin Clad Fire Doors—with Revisions through July 2018
10B—2008
Fire Tests of Door Assemblies—with Revisions through February 2015
10C—2016
Positive Pressure Fire Tests of Door Assemblies
10D—2017
Standard for Fire Tests of Fire Protective Curtain Assemblies
14B—2008
Sliding Hardware for Standard Horizontally Mounted Tin Clad Fire Doors—with Revisions through July 2017
14C—2006
Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs—with Revisions through July 2017
55A—2004
103—2010
Factory-built Chimneys, for Residential Type and Building Heating Appliances—with Revisions through March 2017
127—2011
Factory-built Fireplaces—with Revisions through July 2016
199E—2004
Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers
217—2015
Single and Multiple Station Smoke Alarms—with Revisions through November 2016
263—11
Fire Tests of Building Construction and Materials—with Revisions through March 2018
268—2016
Smoke Detectors for Fire Alarm Systems-with revisions through July 2016
294—2018
Access Control System Units—with Revisions through October 2018
300—2005(R2010)
Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment—with Revisions through December 2014
300A—2006
Outline of Investigation for Extinguishing System Units for Residential Range Top Cooking Surfaces
305—2012
Panic Hardware—with Revisions through March 2017
325—2017
Door, Drapery, Gate, Louver and Window Operations and Systems
555—2006
Fire Dampers—with Revisions through October 2016
555C—2014
Ceiling Dampers—with Revisions through May 2017
555S—2014
Smoke Dampers—with Revisions through October 2016
580—2006
Test for Uplift Resistance of Roof Assemblies—with Revisions through October 2018
641—2010
Type L Low-temperature Venting Systems—with Revisions through April 2018
710B—2011
Recirculating Systems—with Revisions through August 2014
723—2018
Test for Surface Burning Characteristics of Building Materials
723S—2006
Drop-Out Ceilings Installed Beneath Automatic Sprinklers
790—2004
Standard Test Methods for Fire Tests of Roof Coverings—with Revisions through October 2018
793—2008
Automatically Operated Roof Vents for Smoke and Heat—with Revisions through March 2017
864—2014
Control Units and Accessories for Fire Alarm Systems—with Revisions through March 2018
924—2016
Safety Emergency Lighting and Power Equipment—with Revisions through May 2018
1040—1996
Fire Test of Insulated Wall Construction—with Revisions through April 2017
1256—02
Fire Test of Roof Deck Construction—with Revisions through August 2018
1479—2015
Fire Tests of Penetration Firestops
1482—2011
Solid-fuel Type Room Heaters—with Revisions through August 2015
1489—2016
Fire Resistant Pipe Protection Systems Carrying Combustible Liquids
1703—2002
Flat-plate Photovoltaic Modules and Panels—with Revisions through September 2018
1715—97
Fire Test of Interior Finish Material—with Revisions through April 2017
1741—2010
Inverters, Converters, Controllers and Interconnection System Equipment for Use with Distributed Energy Resources—with Revisions through February 2018
1777—2007
Chimney Liners—with Revisions through April 2014
1784—2015
Air Leakage Tests of Door Assemblies
1897—2015
Uplift Tests for Roof Covering Systems
1975—06
Fire Tests for Foamed Plastics Used for Decorative Purposes
1994—2015
Luminous Egress Path Marking Systems
2034—2017
Single- and Multiple-station Carbon Monoxide Alarms—with Revisions through September 2018
2075—2013
Standard for Gas and Vapor Detectors and Sensors-with Revisions through December 2017
2079—2015
Tests for Fire Resistance of Building Joint Systems
2196—2017
Standard for Fire Test for Circuit Integrity of Fire-Resistive Power, Instrumentation, Control and Data Cables
2200—2012
Stationary Engine Generator Assemblies—with Revisions through October 2015
2202—2009
Electric Vehicle (EV) Charging System Equipment-with Revisions through February 2018
2594—2016
Electric Vehicle Supply Equipment
2703—2014
Mounting Systems, Mounting Devices, Clamping/Retention Devices and Ground Lugs for Use with Flat-plate Photovoltaic Modules and Panels-with Revisions through December 2019
7103—19
Outline of Investigation for Building-Integrated Photovoltaic Roof Coverings
61730-1—2017
Photovoltaic (PV) Module Safety Qualification - Part 1: Requirements for Construction
61730-2—2017
Photovoltaic (PV) Module Safety Qualification - Part 2: Requirements for Testing
ULC
Underwriters Laboratories of Canada
13775 Commerce Parkway
Richmond, BC V6V 2V4
CAN/ULC S 102.2—2018
Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings and Miscellaneous Materials and Assemblies
USC
United States Code
732 North Capitol Street NW
Washington, DC 20401-0003
18 USC Part 1, Ch. 40
Importation, Manufacture, Distribution and Storage of Explosive Materials
202
WCLIB
West Coast Lumber Inspection Bureau
P.O. Box 23145
Portland, OR 97223
AITC 104—03
Typical Construction Details
AITC 110—01
Standard Appearance Grades for Structural Glued Laminated Timber
AITC 113—10
Standard for Dimensions of Structural Glued Laminated Timber
AITC 119—96
Standard Specifications for Structural Glued Laminated Timber of Hardwood Species
AITC 200—09
Manufacturing Quality Control Systems Manual for Structural Glued Laminated Timber
WDMA
Window and Door Manufacturers Association
2025 M Street NW, Suite 800
Washington, DC 20006
AAMA/WDMA/CSA 101/I.S.2/A440—17
Specifications for Windows, Doors and Unit Skylights
WRI
Wire Reinforcement Institute, Inc.
942 Main Street, Suite 300
Hartford, CT 06103
WRI/CRSI—81
Design of Slab-on-ground Foundations—with 1996 Update