ADOPTS WITHOUT AMENDMENTS:

International Building Code 2009 (IBC 2009)

Heads up: There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

AA Aluminum Association
1525 Wilson Boulevard, Suite 600
Arlington, VA 22209
 
Standard
reference number
Title Referenced in code section number
ADM1—05 Aluminum Design Manual: Part 1-A Specification for Aluminum Structures, Allowable Stress Design; and Part 1-B—Aluminum Structures, Load and Resistance Factor Design 1604.3.5, 2002.1
ASM 35—00 Aluminum Sheet Metal Work in Building Construction (Fourth Edition) 2002.1
     
AAMA American Architectural Manufacturers Association
1827 Waldon Office Square, Suite 550
Schaumburg, IL 60173 
 
Standard
reference number
Title Referenced in code section number
1402—86 Standard Specifications for Aluminum Siding, Soffit and Fascia . 1404.5.1
AAMA/WDMA/CSA 101/I.S.2/A440—08 North American Fenestration Standard/Specifications for Windows, Doors and Skylights 1715.5.1, 2405.5
     
ACI American Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331 
 
Standard
reference number
Title Referenced in code section number
216.1—07 Standard Method for Determining Fire Resistance of Concrete and Masonry Construction Assemblies Table 720.1(2), 721.1
318—08 Building Code Requirements for Structural Concrete 1604.3.2, 1614.3.1, 1614.4.1, 1704.3.1.3, Table 1704.3, 1704.4.1, Table 1704.4, 1708. 2, 1808.8.2, Table 1808.8.2, 1808.8.5, 1808.8.6, 1810.2.4.1, 1810.3.2.1.1, 1810.3.2.1.2, 1810.3.8.3.1, 1810.3.8.3.3, 1810.3.9.4.2.1, 1810.3.9.4.2.2, 1810.3.11.1, 1901.2, 1901.3, 1901.4, 1902.1, 1903.1, 1904.1, 1904.2, 1904.3, 1904.4.1, 1904.4.2, 1904.5, 1905.1.1, 1905.2, 1905.3, 1905.4, 1905.5, 1905.6.2, 1905.6.3, 1905.6.4, 1905.6.5, 1905.7, 1905.8, 1905.9, 1905.10, 1905.11, 1905.12, 1905.13, 1906.1, 1906.2, 1906.3, 1906.4, 1907.1, 1907.2, 1907.3, 1907.4, 1907.5, 1907.6, 1907.7.1, 1907.7.2, 1907.7.3, 1907.7.4, 1907.7.5, 1907.7.6, 1907.8, 1907.9, 1907.10, 1907.11, 1907.12, 1907.13, 1908.1, 1908.1.1, 1908.1.2, 1908.1.3, 1908.1.4, 1908.1.5, 1908.1.6, 1908.1.7, 1908.1.8, 1908.1.9, 1908.1.10, 1909.1, 1909.3, 1909.4, 1909.5, 1909.6, 1912.1, 2108.3, 2205.3
530—08 Building Code Requirements for Masonry Structures 1405.5, 1405.5.2, 1405.9, 1604.3.4, 1704.5, 1704.5.1, Table 1704.5.1, 1704.5.2, 1704.5.3, Table 1704.5.3, 1807.1.6.3.2, 1808.9, 2101.2.2, 2101.2.3, 2101.2.4, 2101.2.5, 2101.2.6, 2103.1.3.6, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4, 2107.5, 2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2109.3, 2110.1
530.1—08 Specifications for Masonry Structures 1405.5.1, Table 1704.5.1, Table 1704.5.3, 1807.1.6.3, 2103.8, 2103.11, 2103.12, 2103.13, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.2, 2104.3, 2104.4, 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3
     
AF&PA American Forest & Paper Association
1111 19th St, NW Suite 800
Washington, DC 20036 
 
Standard
reference number
Title Referenced in code section number
WCD No. 4—89 Wood Construction Data—Plank and Beam Framing for Residential Buildings 2306.1.2
WFCM—01 Wood Frame Construction Manual for One- and Two-family Dwellings 1609.1.1, 1609.1.1.1, 2301.2, 2308.1, 2308.2.1
NDS—05 National Design Specification (NDS) for Wood Construction with 2005 Supplement 721.6.3.2, 1716.1.1, 1716.1.4, 1809.12, 1810.3.2.4, Table 1810.3.2.6, 2302.1, 2304.12, 2306.1, Table 2306.2.1(1), Table 2306.2.1(2), Table 2306.3, Table 2306.6, 2307.1, 2307.1.1
AF&PA—93 Span Tables for Joists and Rafters 2306.1.1, 2308.8, 2308.10.2, 2308.10.3
ANSI/AF&PA PWF—07 Permanent Wood Foundation Design Specification 1805.2, 1807.1.4, 2304.9.5.2
ANSI/AF&PA SDPWS—08 Special Design Provisions for Wind and Seismic 1613.6.1, 2305.1, 2306.1, 2306.2.1, 2306.2.2, 2306.2.3, 2306.3, Table 2306.3, 2306.4, 2306.5, 2306.6, 2306.7, Table 2306.7, 2307.1, 2307.1.1
     
AISC American Institute of Steel Construction
One East Wacker Drive, Suite 700
Chicago, IL 60601-18021 
 
Standard
reference number
Title Referenced in code section number
341—05 Seismic Provisions for Structural Steel Buildings, including Supplement No. 1 dated 2005 1613.6.2, 1707.2, 1708.3, 2205.2.1, 2205.2.2, 2205.3, 2205.3.1
360—05 Specification for Structural Steel Buildings 1604.3.3, Table 1704.3, 1704.3.3, 2203.1, 2203.2, 2205.1, 2205.3
     
AISI American Iron and Steel Institute
1140 Connecticut Avenue, 705
Suite 705
Washington, DC 20036 
 
Standard
reference number
Title Referenced in code section number
S100—07 North American Specification for the Design of Cold-formed Steel Structural Members 1604.3.3, 2203.1, 2203.2, 2209.1, 2210.2, 2210.4, 2210.5
S200—07 North American Standard for Cold-formed Steel Framing—General Provisions 2203.1, 2203.2, 2210.1
S210—07 North American Standard for Cold-formed Steel Framing—Floor and Roof System Design 2210.5
S211—07 North American Standard for Cold-formed Steel Framing—Wall Stud Design 2210.4
S212—07 North American Standard for Cold-formed Steel Framing—Header Design 2210.2
S213—07 North American Standard for Cold-formed Steel Framing—Lateral Design 2210.6
S214—07 North American Standard for Cold-formed Steel Framing—Truss  
  Design, with Supplement 2, dated 2008 2210.3.11
S230—07 Standard for Cold-formed Steel Framing—Prescriptive Method for One- and Two-family Dwellings, with Supplement 2, dated 2008 1609.1.1, 1609.1.1.1, 2210.7
     
AITC American Institute of Timber Construction
Suite 140
7012 S. Revere Parkway
Englewood, CO 80112 
 
Standard
reference number
Title Referenced in code section number
AITC Technical Note 7—96 Calculation of Fire Resistance of Glued Laminated Timbers 721.6.3.3
AITC 104—03 Typical Construction Details 2306.1
AITC 110—01 Standard Appearance Grades for Structural Glued Laminated Timber 2306.1
AITC 113—01 Standard for Dimensions of Structural Glued Laminated Timber 2306.1
AITC 117—04 Standard Specifications for Structural Glued Laminated Timber of Softwood Species 2306.1
AITC 119—96 Standard Specifications for Structural Glued Laminated Timber of Hardwood Species 2306.1
AITC 200—04 Manufacturing Quality Control Systems Manual for Structural Glued Laminated Timber 2306.1
ANSI/AITC A 190.1—07 Structural Glued Laminated Timber 2303.1.3, 2306.1
     
ALI Automotive Lift Institute
P.O. Box 85
Courtland, NY 13045 
 
Standard
reference number
Title Referenced in code section number
ALI ALCTV—2006 Standard for Automobile Lifts—Safety Requirements for Construction, Testing and Validation (ANSI) 3001.2
     
ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036 
 
Standard
reference number
Title Referenced in code section number
A13.1—96 (Reaffirmed 2002) Scheme for the Identification of Piping Systems 415.8.6.4
A108.1A—99 Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar 2103.10
A108.1B—99 Installation of Ceramic Tile, quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex-portland Mortar 2103.10
A108.4—99 Installation of Ceramic Tile with Organic Adhesives or Water-cleanable Tile-setting Epoxy Adhesive 2103.10.6
A108.5—99 Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex-portland Cement Mortar 2103.10.1, 2103.10.2
A108.6—99 Installation of Ceramic Tile with Chemical-resistant,Water Cleanable Tile-setting and -grouting Epoxy 2103.10.3
A108.8—99 Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout 2103.10.4
A108.9—99 Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout 2103.10.5
A108.10—99 Installation of Grout in Tilework 2103.10.7
A118.1—99 American National Standard Specifications for Dry-set Portland Cement Mortar 2103.10.1
A118.3—99 American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy and Water Cleanable Tile-setting Epoxy Adhesive 2103.10.3
A118.4—99 American National Standard Specifications for Latex-portland Cement Mortar 2103.10.2
A118.5—99 American National Standard Specifications for Chemical Resistant Furan Mortar and Grouts for Tile Installation 2103.10.4
A118.6—99 American National Standard Specifications for Cement Grouts for Tile Installation 2103.10.7
A118.8—99 American National Standard Specifications for Modified Epoxy Emulsion Mortar/Grout 2103.10.5
A136.1—99 American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile 2103.10.6
A137.1—88 American National Standard Specifications for Ceramic Tile 2103.5
A208.1—99 Particleboard 2303.1.7, 2303.1.7.1
Z 97.1—04 Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test 2406.1.2, 2406.2, Table 2406.2(2), 2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1, 2408.3, 2409.1, 2409.2, 2409.3.1
     
APA APA - Engineered Wood Association
7011 South 19th
Tacoma, WA 98466 
 
Standard
reference number
Title Referenced in code section number
APA PDS—04 Panel Design Specification 2306.1
APA PDS Supplement 1—90 Design and Fabrication of Plywood Curved Panels (revised 1995) 2306.1
APA PDS Supplement 2—92 Design and Fabrication of Plywood-lumber Beams (revised 1998) 2306.1
APA PDS Supplement 3—90 Design and Fabrication of Plywood Stressed-skin Panels (revised 1996) 2306.1
APA PDS Supplement 4—90 Design and Fabrication of Plywood Sandwich Panels (revised 1993) 2306.1
APA PDS Supplement 5—95 Design and Fabrication of All-plywood Beams (revised 1995) 2306.1
EWS R540—02 Builders Tips: Proper Storage and Handling of Glulam Beams 2306.1
EWS S475—01 Glued Laminated Beam Design Tables 2306.1
EWS S560—03 Field Notching and Drilling of Glued Laminated Timber Beams 2306.1
EWS T300—05 Glulam Connection Details 2306.1
EWS X440—03 Product Guide—Glulam 2306.1
EWS X450—01 Glulam in Residential Construction—Western Edition 2306.1
     
APSP The Association of Pool & Spa Professionals
2111 Eisenhower Avenue
Alexandria, VA 22314 
 
Standard
reference number
Title Referenced in code section number
ANSI/APSP 7—06 Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs and Catch Basins 3109.5
     
ASABE American Society of Agricultural and Biological Engineers
2950 Niles Road
St. Joseph, MI 49085 
 
Standard
reference number
Title Referenced in code section number
EP 484.2 (2003) Diaphragm Design of Metal-clad, Post-frame Rectangular Buildings 2306.1
EP 486.1 (2000) Shallow-post Foundation Design 2306.1
EP 559 (1997) Design Requirements and Bending Properties for Mechanically Laminated Columns 2306.1
     
ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400 
 
Standard
reference number
Title Referenced in code section number
3—91 Structural Design of Composite Slabs 1604.3.3, 2209.2.1
5—08 Building Code Requirements for Masonry Structures 1405.6, 1405.6.2, 1405.10, 1604.3.4, 1704.5, 1704.5.1, Table 1704.5.1, 1704.5.2, 1704.5.3, Table 1704.5.3, 1807.1.6.3.2, 1808.9, 2101.2.2, 2101.2.3, 2101.2.4, 2101.2.5, 2101.2.6, 2103.1.3.6, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4, 2107.5, 2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2109.3, 2110.1
6—08 Specification for Masonry Structures 1405.6.1, Table 1704.5.1, Table 1704.5.3, 1807.1.6.3, 2103.8, 2103.11, 2103.12, 2103.13, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.2, 2104.3, 2104.4, 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3
7—05 Minimum Design Loads for Buildings and Other Structures including Supplements No. 1 and 2, excluding Chapter 14 and Appendix 11A Table 1504.8, 1602.1, 1604.3, 1604.8.2, 1604.10, 1605.1, 1605.2.2, 1605.3.1.2, 1605.3.2, 1607.11.1, 1608.1, 1608.2, 1609.1.1, 1609.1.1.2.1, 1609.1.1.2.2, 1609.1.2, 1609.3, 1609.4.4, 1609.5.1, 1609.5.3, 1609.6, 1609.6.1, 1609.6.1.1, 1609.6.2, Table 1609.6.2(2), 1609.6.3, 1609.6.4.1, 1609.6.4.2, 1611.2, 1612.2, 1612.4, 1613.1, 1613.2, Table 1613.5.3(1), Table 1613.5.3(2), 1613.5.6, 1613.5.6.1, 1613.5.6.2, 1613.6, 1613.6.1, 1613.6.2, 1613.6.3, 1613.6.4, 1613.6.5, 1613.6.6, 1613.6.7, 1613.7, 1702.1, 1705.3.4, 1708.1, 1708.5, 1808.3.1, 1810.3.6.1, 1810.3.9.4, 1810.3.11.2, 1810.3.12, 1908.1.1, 1908.1.2, 1908.1.9, 2205.2.1, 2205.3, 2205.3.1, 2208.1, Table 2304.6.1, Table 2306.7, Table 2308.10.1, 2404.1, 2505.1, 2505.2, 3404.4, 3404.5
8—02 Standard Specification for the Design of Cold-formed Stainless Steel Structural Members 1604.3.3, 2209.1
19—96 Structural Applications of Steel Cables for Buildings 2207.1, 2207.2
24—05 Flood Resistant Design and Construction 1203.3.2, 1612.4, 1612.5, 3001.2, G103.1, G401.3, G401.4
29—05 Standard Calculation Methods for Structural Fire Protection 721.1
32—01 Design and Construction of Frost Protected Shallow Foundations 1809.5
     
ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990 
 
Standard
reference number
Title Referenced in code section number
A17.1/CSA B44—2007 Safety Code for Elevators and Escalators 907.3.3, 911.1.5, 1007.4, 1607.8.1, 1613.6.5, 3001.2, 3001.4, 3002.5, 3003.2, 3007.1, 3008.3, 3008.12, 3008.14.1, 3411.8.2
A18.1—2005 Safety Standard for Platform Lifts and Stairway Chairlifts 1109.7, 2702.2.6, 3411.8.3
A90.1—03 Safety Standard for Belt Manlifts 3001.2
B16.18—2001 (Reaffirmed 2005) Cast Copper Alloy Solder Joint Pressure Fittings 909.13.1
B16.22—2001 (Reaffirmed 2005) Wrought Copper and Copper Alloy Solder Joint Pressure Fittings 909.13.1
B20.1—2006 Safety Standard for Conveyors and Related Equipment 3001.2, 3005.3
B31.3—2004 Process Piping 415.8.6.1
     
ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959 
 
Standard
reference number
Title Referenced in code section number
A 36/A 36M—05 Specification for Carbon Structural Steel 1810.3.2.3
A 153/A 153M—05 Specification for Zinc Coating (Hot-dip) on Iron and Steel Hardware 2304.9.5
A 240/A 240M—07 Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications Table 1507.4.3(1)
A 252—98 (2002) Specification for Welded and Seamless Steel Pipe Piles 1810.3.2.3
A 283/A 283M—03 Specification for Low and Intermediate Tensile Strength Carbon Steel Plates 1810.3.2.3
A 307—04e01 Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength 1911.1
A 416/A 416M—06 Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete 1810.3.2.2
A 463/A 463M—05 Standard Specification for Steel Sheet, Aluminum-coated, by the Hot-dip Process Table 1507.4.3(2)
A 572/A 572M—07 Specification for High-strength Low-alloy Columbium-vanadium Structural Steel 1810.3.2.3
A 588/A 588M—05 Specification for High-strength Low-alloy Structural Steel with 50 ksi (345 MPa) Minimum Yield Point to 4 inches (100 mm) Thick 1810.3.2.3
A 615/A 615M—04a Specification for Deformed and Plain Billet-steel Bars for Concrete Reinforcement 1708.2, 1810.3.10.2
A 653/A 653M—07 Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron Alloy-coated Galvannealed by the Hot-dip Process Table 1507.4.3(1), Table 1507.4.3(2), 2304.9.5.1
A 690/A 690M—07 Standard Specification for High-strength Low-alloy Nickel, Copper, Phosphorus Steel H-piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Marine Environments 1810.3.2.3
A 706/A 706M—05a Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement Table 1704.3, 1704.4.1, 2107.4, 2108.3
A 722/A 722M—07 Specification for Uncoated High-strength Steel Bar for Prestressing Concrete 1810.3.10.2
A 755/A 755M—03 Specification for Steel Sheet, Metallic-coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products Table 1507.4.3(1), Table 1507.4.3(2)
A 792/A 792M—06a Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process Table 1507.4.3(1), Table 1507.4.3(2)
A 875/A 875M—06 Standard Specification for Steel Sheet Zinc-5 percent, Aluminum Alloy-coated by the Hot-dip Process Table 1507.4.3(2)
A 913/A 913M—04 Specification for High-strength Low-alloy Steel Shapes of Structural Quality, Produced by Quenching and Self-tempering Process (QST) 1810.3.2.3
A 924/A 924M—07 Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process Table 1507.4.3(1)
A 992/A 992M—06a Standard Specification for Structural Shapes 1810.3.2.3
B 42—02e01 Specification for Seamless Copper Pipe, Standard Sizes 909.13.1
B 43—98(2004) Specification for Seamless Red Brass Pipe, Standard Sizes 909.13.1
B 68—02 Specification for Seamless Copper Tube, Bright Annealed (Metric) 909.13.1
B 88—03 Specification for Seamless Copper Water Tube 909.13.1
B 101—02 Specification for Lead-coated Copper Sheet and Strip for Building Construction Table 1404.5.3, Table 1507.2.9.2, Table 1507.4.3(1)
B 209—06 Specification for Aluminum and Aluminum Alloy Steel and Plate Table 1507.4.3(1)
B 251—02e01 Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube 909.13.1
B 280—03 Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service 909.13.1
B 370—03 Specification for Cold-rolled Copper Sheet and Strip for Building Construction 1404.5.2, Table 1507.2.9.2, Table 1507.4.3(1)
B 695—04 Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel 2304.9.5.1, 2304.9.5.3
C 5—03 Specification for Quicklime for Structural Purposes Table 2507.2
C 22/C 22M—00 (2005)e01 Specification for Gypsum Table 2506.2
C 27—98 (2002) Specification for Standard Classification of Fireclay and High-alumina Refractory Brick 2111.5
C 28/C 28M—00 (2005) Specification for Gypsum Plasters Table 2507.2
C 31/C 31M—06 Practice for Making and Curing Concrete Test Specimens in the Field Table 1704.4
C 33—03 Specification for Concrete Aggregates 721.3.1.4, 721.4.1.1.3
C 34—03 Specification for Structural Clay Load-bearing Wall Tile 2103.2
C 35—01(2005) Specification for Inorganic Aggregates for Use in Gypsum Plaster Table 2507.2
C 36/C 36M—03 Specification for Gypsum Wallboard Figure 721.5.1(2), Figure 721.5.1(3), Table 2506.2
C 37/C 37M—01 Specification for Gypsum Lath Table 2507.2
C 55—06e01 Specification for Concrete Building Brick Table 721.3.2, 2103.1, 2105.2.2.1.2
C 56—05 Specification for Structural Clay Nonload Bearing Tile 2103.2
C 59/C 59M—00 (2006) Specification for Gypsum Casting and Molding Plaster Table 2507.2
C 61/C 61M—00 (2006) Specification for Gypsum Keene's Cement Table 2507.2
C 62—05 Specification for Building Brick (Solid Masonry Units Made from Clay or Shale) 1807.1.6.3, 2103.2, 2105.2.2.1.1
C 67—07 Test Methods of Sampling and Testing Brick and Structural Clay Tile 721.4.1.1.1, 2109.3.1.1
C 73—05 Specification for Calcium Silicate Face Brick (Sand-lime Brick) Table 721.3.2, 2103.1
C 79—04a Specification for Treated Core and Nontreated Core Gypsum Sheathing Board Table 2506.2
C 90—06b Specification for Loadbearing Concrete Masonry Units Table 721.3.2, 1807.1.6.3, 2103.1
C 91—05 Specification for Masonry Cement Table 2507.2
C 94/C 94M—07 Specification for Ready-mixed Concrete .110.3.1
C 126—99 (2005) Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick and Solid Masonry Units 2103.2
C 140—07 Test Method Sampling and Testing Concrete Masonry Units and Related Units 721.3.1.2
C 150—07 Specification for Portland Cement Table 2507.2
C 172—04 Practice for Sampling Freshly Mixed Concrete Table 1704.4
C 199—84 (2005) Test Method for Pier Test for Refractory Mortars 2111.5, 2111.8, 2113.12
C 206—03 Specification for Finishing Hydrated Lime Table 2507.2
C 208—95 (2001) Specification for Cellulosic Fiber Insulating Board Table 1508.2, 2303.1.5
C 212—00 (2006) Specification for Structural Clay Facing Tile 2103.2
C 216—07 Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) 1807.1.6.3, 2103.2, 2105.2.2.1.1
C 270—07 Specification for Mortar for Unit Masonry 2103.8
C 315—07 Specification for Clay Flue Liners and Chimney Pots 2111.8, 2113.11, Table 2113.16(1)
C 317/C 317M—00 (2005) Specification for Gypsum Concrete 1914.1
C 330—05 Specification for Lightweight Aggregates for Structural Concrete 721.1.1
C 331—05 Specification for Lightweight Aggregates for Concrete Masonry Units 721.3.1.4, 721.4.1.1.3
C 406—06e01 Specification for Roofing Slate 1507.7.5
C 442/C 442M—04 Specification for Gypsum Backing Board and Coreboard and Gypsum Shaftliner Board Table 2506.2
C 472—99 (2004) Specification for Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum Concrete Table 2506.2
C 473—06a Test Method for Physical Testing of Gypsum Panel Products Table 2506.2
C 474—05 Test Methods for Joint Treatment Materials for Gypsum Board Construction Table 2506.2
C 475/C 475M—02 (2007) Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard Table 2506.2
C 503—05 Specification for Marble Dimension Stone (Exterior) 2103.4
C 514—04 Specification for Nails for the Application of Gypsum Board Table 720.1(2), Table 720.1(3), Table 2306.7, Table 2506.2
C 516—02 Specifications for Vermiculite Loose Fill Thermal Insulation 721.3.1.4, 721.4.1.1.3
C 547—06 Specification for Mineral Fiber Pipe Insulation Table 720.1(2), Table 720.1(3)
C 549—06 Specification for Perlite Loose Fill Insulation 721.3.1.4, 721.4.1.1.3
C 552—03 Standard Specification for Cellular Glass Thermal Insulation Table 1508.2
C 557—03e01 Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing Table 2506.2
C 568—03 Specification for Limestone Dimension Stone 2103.4
C 578—07 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation Table 1508.2
C 587—04 Specification for Gypsum Veneer Plaster Table 2507.2
C 588/C 588M—01 Specification for Gypsum Base for Veneer Plasters Table 2507.2
C 595—07 Specification for Blended Hydraulic Cements Table 2507.2
C 615—03 Specification for Granite Dimension Stone 2103.4
C 616—03 Specification for Quartz Dimension Stone 2103.4
C 629—03 Specification for Slate Dimension Stone 2103.4
C 630/C 630M—03 Specification for Water-resistant Gypsum Backing Board Table 2506.2
C 631—95a (2004) Specification for Bonding Compounds for Interior Gypsum Plastering Table 2507.2
C 635—04 Specification for the Manufacturer, Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings 808.1.1, 2506.2.1, H107.1.1
C 636/C 636M—06 Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels 808.1.1
C 645—07 Specification for Nonstructural Steel Framing Members Table 2506.2, Table 2507.2
C 652—05a Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale) 1807.1.6.3, 2103.2, 2105.2.2.1.1
C 728—05 Standard Specification for Perlite Thermal Insulation Board Table 1508.2
C 744—05 Specification for Prefaced Concrete and Calcium Silicate Masonry Units Table 721.3.2, 2103.1
C 754—04 Specification for Installation of Steel Framing Members to Receive Screw-attached Gypsum Panel Products Table 2508.1, Table 2511.1.1
C 836—06 Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course 1507.15.2
C 840—07 Specification for Application and Finishing of Gypsum Board Table 2508.1, 2509.2
C 841—03 Specification for Installation of Interior Lathing and Furring Table 2508.1, Table 2511.1.1
C 842—05 Specification for Application of Interior Gypsum Plaster Table 2511.1.1, 2511.3, 2511.4
C 843—99 (2006) Specification for Application of Gypsum Veneer Plaster Table 2511.1.1
C 844—04 Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster Table 2508.1
C 847—06 Specification for Metal Lath Table 2507.2
C 887—05 Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar 1805.2.2, 2103.9
C 897—05 Specification for Aggregate for Job-mixed Portland Cement-based Plaster Table 2507.2
C 920—05 Standard for Specification for Elastomeric Joint Sealants Table 2506.2
C 926—98a (2005) Specification for Application of Portland Cement-based Plaster 2109.3.4.6, 2510.3, Table 2511.1.1, 2511.3, 2511.4, 2512.1, 2512.1.2, 2512.2, 2512.6, 2512.8.2, 2512.9, 2513.7
C 931/C 931M—04 Specification for Exterior Gypsum Soffit Board Table 2506.2
C 932—06 Specification for Surface-applied Bonding Compounds Agents for Exterior Plastering Table 2507.2
C 933—05 Specification for Welded Wire Lath Table 2507.2
C 946—91 (2001) Specification for Practice for Construction of Dry-stacked, Surface-bonded Walls 2103.9, 2109.2.2
C 954—04 Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 inch (0.84 mm) to 0.112 inch (2.84 mm) in Thickness Table 2506.2, Table 2507.2
C 955—06 Standard Specification for Load-bearing Transverse and Axial Steel Studs, Runners Tracks, and Bracing or Bridging, for Screw Application of Gypsum Panel Products and Metal Plaster Bases Table 2506.2, Table 2507.2
C 956—04 Specification for Installation of Cast-in-place Reinforced Gypsum Concrete 1914.1
C 957—06 Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane with Integral Wearing Surface 1507.15.2
C 960—04 Specification for Predecorated Gypsum Board Table 2506.2
C 1002—04 Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs Table 2506.2, Table 2507.2
C 1007—04 Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories .Table 2508.1, Table 2511.1.1
C 1019—05 Test Method of Sampling and Testing Grout 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3
C 1029—05a Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation 1507.14.2
C 1032—06 Specification for Woven Wire Plaster Base Table 2507.2
C 1047—05 Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base Table 2506.2, Table 2507.2
C 1063—06 Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster 2109.3.4.6, 2510.3, Table 2511.1.1, 2512.1.1
C 1088—07a Specification for Thin Veneer Brick Units Made from Clay or Shale Table 720.1(2), 2103.2
C 1167—03 Specification for Clay Roof Tiles 1507.3.4
C 1177/C 1177M—06 Specification for Glass Mat Gypsum Substrate for Use as Sheathing Table 2506.2
C 1178/C 1178M—06 Specification for Coated Mat Water-resistant Gypsum Backing Panel Table 2506.2, 2509.2
C 1186—07 Specification for Flat Nonasbestos Fiber Cement Sheets 1404.10
C 1261—07 Specification for Firebox Brick for Residential Fireplaces 2111.5, 2111.8
C 1278/C 1278M—06 Specification for Fiber-reinforced Gypsum Panels Table 2506.2
C 1280—04 Specification for Application of Gypsum Sheathing Table 2508.1, 2508.2
C 1283—07 Practice for Installing Clay Flue Lining 2113.12
C 1288—99 (2004) Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets 2509.2
C 1289—07 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board Table 1508.2
C 1314—07 Test Method for Compressive Strength of Masonry Prisms 2105.2.2.2.2, 2105.3.1, 2105.3.2
C 1325—04 Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Interior Substrate Sheets 2509.2
C 1328—05 Specification for Plastic (Stucco Cement) Table 2507.2
C 1386—07 Specification for Precast Autoclaved Aerated Concrete (AAC) Wall Construction Units 2102.1, 2103.3, 2105.2.2.1.3
C 1395/C 1395M—04 Specification for Gypsum Ceiling Board Table 2506.2
C 1396M—06a Specification for Gypsum Board Table 2506.2
C 1405—07 Standard Specification for Glazed Brick (Single Fired, Solid Brick Units) 2103.2
C 1492—03 Standard Specification for Concrete Roof Tile 1507.3.5
C 1629/C 1629M—06 Standard Classification for Abuse-resistant Nondecorated Interior Gypsum Panel Products and Fiber-reinforced Cement Panels 403.2.3.1, 403.2.3.2, 403.2.3.4
C 1658/C 1658M—06 Standard Specification for Glass Mat Gypsum Panels 1810.3.2.4, Table 2506.2
D 25—99 (2005) Specification for Round Timber Piles 2303.1.11
D 41—05 Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 43—00 (2006) Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 56—05 Test Method for Flash Point By Tag Closed Tester 307.2
D 86—07a Test Method for Distillation of Petroleum Products at Atmospheric Pressure 307.2
D 93—07 Test Method for Flash Point By Pensky-Martens Closed Cup Tester 307.2
D 225—04 Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules 1507.2.5
D 226—06 Specification for Asphalt-saturated Organic Felt Used in Roofing and Waterproofing 1404.2, 1507.2.3, 1507.3.3, 1507.5.3, 1507.6.3, 1507.7.3, Table 1507.8, 1507.8.3, 1507.9.3, 1507.9.5, Table 1507.10.2
D 227—03 Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing Table 1507.10.2
D 312—00 (2006) Specification for Asphalt Used in Roofing Table 1507.10.2
D 422—63 (2002)e01 Test Method for Particle-size Analysis of Soils 1803.5.3
D 448—03a Standard Classification for Sizes of Aggregate for Road and Bridge Construction 1507.12.3, 1507.13.3
D 450—07 Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 635—06 Test Method for Rate of Burning and/or Extent and Time of Burning of Self-supporting Plastics in a Horizontal Position 2606.4, H107.1.1
D 1143/D 1143M—07 Test Method for Piles Under Static Axial Compressive Load 1810.3.3.1.2
D 1227—95 (2007) Specification for Emulsified Asphalt Used as a Protective Coating for Roofing Table 1507.10.2, 1507.15.2
D 1557—02e01 Test Method for Laboratory Compaction Characteristics of Soil Using Modified Effort [56,000 ft-lb/ft3 (2,700 KN m/m3)] 1704.7, 1804.5, J107.6
D 1586—99 Specification for Penetration Test and Split-barrel Sampling of Soils 1613.5.5
D 1761—06 Test Method for Mechanical Fasteners in Wood 1716.1.1, 1716.1.2, 1716.1.3
D 1863—05 Specification for Mineral Aggregate Used on Built-up Roofs Table 1507.10.2
D 1929—96 (2001)e01 Test Method for Determining Ignition Properties of Plastics 402.16.4, 406.5.3, 1407.11.2.1, 2606.4
D 1970—01 Specification for Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection 1507.2.4, 1507.2.9.2, 1507.3.9, 1507.5.7, 1507.8.8, 1507.9.9
D 2166—06 Test Method for Unconfined Compressive Strength of Cohesive Soil 1613.5.5
D 2178—04 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D 2216—05 Test Method for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass 1613.5.5
D 2487—06 Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System) Table 1610.1, 1802.3.1
D 2626—04 Specification for Asphalt Saturated and Coated Organic Felt Base Sheet Used in Roofing 1507.3.3, Table 1507.10.2
D 2822—05 Specification for Asphalt Roof Cement Table 1507.10.2
D 2823—05 Specification for Asphalt Roof Coatings Table 1507.10.2
D 2843—99 (2004)e01 Test for Density of Smoke from the Burning or Decomposition of Plastics 2606.4
D 2850—03a Test Method for Unconsolidated, Undrained Triaxial Compression Test on Cohesive Soils 1613.5.5
D 2898—07 Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing 1505.1, 2303.2.4, 2303.2.6
D 3019—94 (2007) Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered Table 1507.10.2
D 3161—06 Test Method for a Wind Resistance of Asphalt Shingles (Fan Induced Method) 1507.2.7.1, Table 1507.2.7.1(2)
D 3200—74 (2005) Standard Specification and Test Method for Establishing Recommended Design Stresses for Round Timber Construction Poles 2303.1.11
D 3201—07 Test Method for Hygroscopic Properties of Fire-retardant-treated Wood and Wood-based Products 2303.2.7
D 3278—(2004)e01 Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 307.2
D 3462—07 Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules 1507.2.5
D 3468—99 (2006)e01 Specification for Liquid-applied Neoprene and Chlorosulfonated Polyethylene Used in Roofing and Waterproofing 1507.15.2
D 3679—06a Specification for Rigid Poly [Vinyl Chloride (PVC) Siding] 1404.9, 1405.14
D 3689—90 (1995) Method for Testing Individual Piles Under Static Axial Tensile Load 1810.3.3.1.5
D 3737—07 Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam) 2303.1.3
D 3746—85 (2002) Test Method for Impact Resistance of Bituminous Roofing Systems 1504.7
D 3747—79 (2007) Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation Table 1507.10.2
D 3909—97b (2004)e01 Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules 1507.2.9.2, 1507.6.5, Table 1507.10.2
D 3957—06 Standard Practices for Establishing Stress Grades for Structural Members Used in Log Buildings 2303.1.10
D 4022—07 Specification for Coal Tar Roof Cement, Asbestos Containing Table 1507.10.2
D 4272—03 Test Method for Total Energy Impact of Plastic Films by Dart Drop 1504.7
D 4318—05 Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils 1613.5.5, 1803.5.3
D 4434—06 Specification for Poly (Vinyl Chloride) Sheet Roofing 1507.13.2
D 4479—07 Specification for Asphalt Roof Coatings—Asbestos-free Table 1507.10.2
D 4586—00 Specification for Asphalt Roof Cement—Asbestos-free Table 1507.10.2
D 4601—04 Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing Table 1507.10.2
D 4637—04 Specification for EPDM Sheet Used in Single-ply Roof Membrane 1507.12.2
D 4829—07 Test Method for Expansion Index of Soils 1803.5.3
D 4869—05e01 Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing 1507.2.3, 1507.5.3, 1507.6.3, 1507.7.3, 1507.8.3, 1507.9.3
D 4897—01 Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing Table 1507.10.2
D 4945—00 Test Method for High-strain Dynamic Testing of Piles .1810.3.3.1.2
D 4990—97a (2005)e01 Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D 5019—07 Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane 1507.12.2
D 5055—05 Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists 2303.1.2
D 5456—05a Specification for Evaluation of Structural Composite Lumber Products 2303.1.9
D 5516—03 Test Method of Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures 2303.2.5.1
D 5643—06 Specification for Coal Tar Roof Cement, Asbestos-free Table 1507.10.2
D 5664—02 Test Methods for Evaluating the Effects of Fire-retardant Treatment and Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber 2303.2.5.2
D 5665—99a (2006) Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing Table 1507.10.2
D 5726—98 (2005) Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing Table 1507.10.2
D 6083—05e01 Specification for Liquid Applied Acrylic Coating Used in Roofing Table 1507.10.2, 1507.15.2
D 6162—00A Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements 1507.11.2
D 6163—00e01 Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements 1507.11.2
D 6164—05 Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Metal Materials Using Polyester Reinforcements 1507.11.2
D 6222—02e01 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements 1507.11.2
D 6223—02 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements 1507.11.2
D 6298—05 Specification for Fiberglass Reinforced Styrene-butadiene-styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface 1507.11.2
D 6305—02e01 Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing 2303.2.5.1
D 6380—03 Standard Specification for Asphalt Roll Roofing (Organic) Felt 1507.2.9.2, 1507.3.3, 1507.6.5
D 6509—00 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous base Sheet Materials Using Glass Fiber Reinforcements 1507.11.2
D 6694—07 Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing 1507.15.2
D 6754—02 Standard Specification for Ketone Ethylene Ester Based Sheet Roofing 1507.13.2
D 6757—07 Standard Specification for Inorganic Underlayment for Use with Steep Slope Roofing Products 1507.2.3
D 6841—03 Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber 2303.2.5.2
D 6878—06a Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing 1507.13.2
D 6947—07 Standard Specification for Liquuid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System 1507.15.2
D 7158—07 Standard Test Method for Wind Resistance of Sealed Asphalt Shingles (Uplift Force/Uplift Resistance Method) 1507.2.7.1, Table 1507.2.7.1(1)
E 84—07 Test Methods for Surface Burning Characteristics of Building Materials 402.11, 402.16.4, 406.5.3, 703.4.2, 719.1, 719.4, 802.1, 803.1.1, 803.9, 806.5, 1407.9, 1407.10.1, 2303.2, 2603.3, 2603.4.1.13, 2603.5.4, 2604.2.4, 2606.4, 3105.4, D102.2.8
E 90—04 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements 1207.2, 1207.2.1
E 96/E 96M—05 Test Method for Water Vapor Transmission of Materials . 202, 1203.2
E 108—07a Test Methods for Fire Tests of Roof Coverings 1505.1, 2603.6, 2610.2, 2610.3
E 119—07 Test Methods for Fire Tests of Building Construction and Materials 703.2, 703.2.1, 703.2.3, 703.3, 703.5, 704.12, 705.7, 705.8.5, 707.6, 712.3.2, 713.3.1, 713.4.1.1, 714.1, 715.2, 715.4.5, 716.5.2, 716.5.3, 716.6.1, 716.6.2.1, Table 720.1(1), 1407.10.2, 2103.2, 2603.4, 2603.5.1
E 136—04 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 703.4.1
E 330—02 Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference 1715.5.2
E 331—00 Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference 1403.2
E 492—04 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-ceiling Assemblies Using the Tapping Machine 1207.3
E 605—93 (2006) Test Method for Thickness and Density of Sprayed Fire-resistive Material (SFRM) Applied to Structural Members 1704.12.4.1, 1704.12.4.2, 1704.12.4.3, 1704.12.5
E 681—04 Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases 307.2
E 736—00 (2006) Test Method for Cohesion/Adhesion of Sprayed Fire-resistive Materials Applied to Structural Members 704.13.2, 1704.12.6
E 814—06 Test Method of Fire Tests of Through-penetration Firestops 702.1, 713.3.1.2, 713.3.2, 713.4.1.1.2
E 970—00 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source 719.3.1
E 1300—04e01 Practice for Determining Load Resistance of Glass in Buildings 2404.1, 2404.2, 2404.3.1, 2404.3.2, 2404.3.3, 2404.3.4, 2404.3.5
E 1354—04a Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter 402.12.1
E 1592—01 Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference 1504.3.2
E 1602—03 Guide for Construction of Solid Fuel-burning Masonry Heaters 2112.2
E 1886—05 Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Missiles and Exposed to Cyclic Pressure Differentials 1609.1.2
E 1966—01 Test Method for Fire-resistant Joint Systems 702.1, 714.3
E 1996—06 Specification for Performance of Exterior Windows, Glazed Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes 1609.1.2, 1609.1.2.1
E 2072—04 Standard Specification for Photoluminescent (Phosphorescent) Safety Markings 1024.4
E 2273—03 Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies 1408.4.1
E 2307—04e01 Standard Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems Using Intermediate-scale, Multistory Test Apparatus 714.4
E 2404—07a Standard Practice for Specimen Preparation and Mounting of Textile, Paper or Vinyl Wall or Ceiling Coverings to Assess Surface Burning Characteristics 803.1.4
E 2568—07 Standard Specification for PB Exterior Insulation and Finish Systems (EIFS) 1408.2
E 2570—07 Standard Test Method for Evaluating Water-resistive Barrier (WRB) Coatings Used Under Exterior Insulation and Finish Systems (EIFS) for EIFS with Drainage 1408.4.1.1, 1704.12.1
E 2573—07 Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface Burning Characteristics 803.9
F 547—01 Terminology of Nails for Use with Wood and Wood-based Materials Table 2506.2
F 1346—91 (2003) Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs 3109.4, 3109.4.1.8
F 1667—05 Specification for Driven Fasteners: Nails, Spikes and Staples Table 720.1(2), Table 720.1(3), 1507.2.6, 2303.6, Table 2506.2
F 2006—00 (2005) Standard/Safety Specification for Window Fall Prevention Devices for Nonemergency Escape (Egress) and Rescue (Ingress) Windows 1405.13.2
F 2090—01a (2007) Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms 1405.13.2
F 2200—05 Standard Specification for Automated Vehicular Gate Construction 3110.3
G 152—06 Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6
G 154—05 Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials 1504.6
G 155—05a Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6
     
AWCI Association of the Wall and Ceiling Industry
513 West Broad Street, Suite 210
Falls Church, VA 22046 
 
Standard
reference number
Title Referenced in code section number
12-B—98 Technical Manual 12-B Standard Practice for the Testing and Inspection of Field Applied Thin Film Intumescent Fire-resistive Materials; an Annotated Guide, First Edition 1704.13
     
AWPA American Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784 
 
Standard
reference number
Title Referenced in code section number
C1—03 All Timber Products—Preservative Treatment by Pressure Processes 1505.6
M4—06 Standard for the Care of Preservative-treated Wood Products 1810.3.2.4.1, 2303.1.8
U1—07 USE CATEGORY SYSTEM: User Specification for Treated Wood Except Section 6, Commodity Specification H 1403.5, Table 1507.9.6, 1807.1.4, 1807.3.1, 1809.12, 1810.3.2.4.1, 2303.1.8, 2304.11.2, 2304.11.4, 2304.11.6, 2304.11.7
     
AWS American Welding Society
550 N.W. LeJeune Road
Miami, FL 33126 
 
Standard
reference number
Title Referenced in code section number
D1.1—04 Structural Welding Code—Steel Table 1704.3, 1704.3.1.1
D1.3—98 Structural Welding Code—Sheet Steel Table 1704.3, 1704.3.1.2
D1.4—98 Structural Welding Code—Reinforcing Steel Table 1704.3, 1704.3.1.3, Table 1704.4, 2107.4
     
BHMA Builders Hardware Manufacturers' Association
355 Lexington Avenue, 17th Floor
New York, NY 10017-6603 
 
Standard
reference number
Title Referenced in code section number
A 156.10—06 Power Operated Pedestrian Doors 1008.1.4.2
A 156.19—02 Standard for Power Assist and Low Energy Operated Doors 1008.1.4.2
     
CGSB Canadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6 
 
Standard
reference number
Title Referenced in code section number
37-GP-52M (1984) Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric 1504.7, 1507.12.2
37-GP-56M (1980) Membrane, Modified, Bituminous, Prefabricated and Reinforced for Roofing—with December 1985 Amendment 1507.11.2
CAN/CGSB 37.54—95 Polyvinyl Chloride Roofing and Waterproofing Membrane 1507.13.2
     
CPA Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176 
 
Standard
reference number
Title Referenced in code section number
ANSI A135.4—2004 Basic Hardboard 1404.3.1, 2303.1.6
ANSI A135.5—2004 Prefinished Hardboard Paneling 2303.1.6, 2304.6.2
ANSI A135.6—1998 Hardboard Siding 1404.3.2, 2303.1.6
     
CPSC Consumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814-4408 
 
Standard
reference number
Title Referenced in code section number
16 CFR Part 1201(1977) Safety Standard for Architectural Glazing Material 2406.2, Table 2406.2(1), 2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1, 2408.3, 2409.1, 2409.2, 2409.3.1
16 CFR Part 1209 (1979) Interim Safety Standard for Cellulose Insulation 719.6
16 CFR Part 1404 (1979) Cellulose Insulation 719.6
16 CFR Part 1500 (1991) Hazardous Substances and Articles; Administration and Enforcement Regulations 307.2
16 CFR Part 1500.44 (2001) Method for Determining Extremely Flammable and Flammable Solids 307.2
16 CFR Part 1507 (2001) Fireworks Devices 307.2
16 CFR Part 1630 (2000) Standard for the Surface Flammability of Carpets and Rugs 804.4.1
     
CSA Canadian Standards Association
5060 Spectrum Way
Mississauga, Ontario Canada L4W 5N6 
 
Standard
reference number
Title Referenced in code section number
101/I.S.2/A440—08 Specifications for Windows, Doors and Unit Skylights 1715.5.1, 2405.5
     
CSSB Cedar Shake and Shingle Bureau
P. O. Box 1178
Sumas, WA 98295-1178 
 
Standard
reference number
Title Referenced in code section number
CSSB—97 Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau Table 1507.8.5, Table 1507.9.6
     
DASMA Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland, OH 44115-2851 
 
Standard
reference number
Title Referenced in code section number
ANSI/DASMA 107—1997 (R2004) Room Fire Test Standard for Garage Doors Using Foam Plastic Insulation 2603.4.1.9
108—05 Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference 1715.5.2
115—05 Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure 1609.1.2.2
     
DOC U.S. Department of Commerce
National Institute of Standards and Technology
1401 Constitution Avenue NW
Washington, DC 20230 
 
Standard
reference number
Title Referenced in code section number
PS-1—07 Structural Plywood 2303.1.4, 2304.6.2, Table 2304.7(4), Table 2304.7(5), Table 2306.2.1(1), Table 2306.2.1(2)
PS-2—04 Performance Standard for Wood-based Structural-use Panels 2303.1.4, 2304.6.2, Table 2304.7(5), Table 2306.2.1(1), Table 2306.2.1(2)
PS 20—05 American Softwood Lumber Standard 1810.3.2.4, 2302.1, 2303.1.1
     
DOJ U.S. Department of Justice
950 Pennsylvania Avenue, NW
Civil Rights Division, Disability Rights Section-NYA
Washington, DC 20530 
 
Standard
reference number
Title Referenced in code section number
DOJ 36 CFR Part 1192 American with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles (ADAAG) Department of Justice, 1991 E109.2.4
     
DOL U.S. Department of Labor
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325 
 
Standard
reference number
Title Referenced in code section number
29 CFR Part 1910.1000 (1974) Air Contaminants 902.1
     
DOTn U.S. Department of Transportation
c/o Superintendent of Documents
1200 New Jersey Avenue, SE
Washington, DC 20402-9325 
 
Standard
reference number
Title Referenced in code section number
49 CFR Parts 100-185-2005 Hazardous Materials Regulations 307.2
49 CFR Parts 173.137 (2005) Shippers—General Requirements for Shipments and Packaging—Class 8—Assignment of Packing Group 307.2
49 CFR—1998 Specification of Transportation of Explosive and Other Dangerous Articles, UN 0335, UN 0336 Shipping Containers 307.2
     
EN European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels 
 
Standard
reference number
Title Referenced in code section number
EN 1081-98 Resilient Floor Coverings—Determination of the Electrical Resistance 406.5.2
     
FEMA Federal Emergency Management Agency
Federal Center Plaza
500 C Street S.W.
Washington, DC 20472 
 
Standard
reference number
Title Referenced in code section number
FIA-TB11—01 Crawlspace Construction for Buildings Located in Special Flood Hazard Areas 1805.1.2.1
     
FM Factory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P.O. Box 7500
Johnson, RI 02919 
 
Standard
reference number
Title Referenced in code section number
4450 (1989) Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 1992 1508.1, 2603.3, 2603.4.1.5
4470 (1992) Approval Standard for Class 1 Roof Covers 1504.7
4474 (04) Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures 1504.3.1
4880 (2005) American National Standard for Evaluating Insulated Wall or Wall and Roof/ Ceiling Assemblies, Plastic Interior Finish Materials, Plastic Exterior Building Panels, Wall/Ceiling Coating Systems, Interior and Exterior Finish Systems 2603.4, 2603.9
     
GA Gypsum Association
810 First Street N.E. #510
Washington, DC 20002-4268 
 
Standard
reference number
Title Referenced in code section number
GA 216—07 Application and Finishing of Gypsum Panel Products .Table 2508.1, 2509.2
GA 600—06 Fire-resistance Design Manual, 18th Edition Table 720.1(1), Table 720.1(2), Table 720.1(3)
     
HPVA Hardwood Plywood Veneer Association
1825 Michael Faraday Drive
Reston, VA 20190 
 
Standard
reference number
Title Referenced in code section number
HP-1—2004 Standard for Hardwood and Decorative Plywood 2303.3, 2304.6.2
     
HUD U.S. Department of Housing and Urban Development
451 7th Street, SW
Washington, DC 20410 
 
Standard
reference number
Title Referenced in code section number
HUD 24 CFR Part 3280 (1994) Manufactured Home Construction and Safety Standards G201
     
ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001 
 
Standard
reference number
Title Referenced in code section number
ICC/ANSI A117.1—03 Accessible and Usable Buildings and Facilities 406.2.2, 907.5.2.3.4, 1007.9, 1010.1, 1010.6.5, 1010.9, 1011.3, 1022.8, 1101.2, 1102.1, 1104.4, 1106.7, 1107.2, 1108.2.2, 1108.2.3, 1108.4.1.1, 1108.4.1.2, 1108.4.1.4, 1108.4.1.5, 1109.1, 1109.2, 1109.2.1.1, 1109.2.2, 1109.2.3, 1109.3, 1109.4, 1109.8, 1109.13, 2902.4, 3001.3, 3008.13.1, 3008.13.2, 3411.6, 3411.8.2, 3411.8.3, E101.2, E104.2, E104.2.1, E104.3, E104.3.4, E105.1, E105.2.1, E105.2.2, E105.3, E105.4, E105.6, E106.2, E106.3, E106.4, E106.4.9, E106.5, E107.2, E107.3, E108.3, E108.4, E109.2.1, E109.2.2.1, E109.2.2.2, E109.2.2.3, E109.2.3, E109.2.5, E109.2.6, E109.2.8, E110.2, E110.4
ICC 300—07 ICC Standard on Bleachers, Folding and Telescopic Seating and Grandstands 1028.1.1, Table 1607.1, 3401.1
ICC 400—07 Standard on Design and Construction of Log Structures 2301.2
ICC 500—08 ICC/NSSA Standard on the Design and Construction of Storm Shelters 423.1, 423.2
ICC 600—08 Standard for Residential Construction in High Wind Regions 1609.1.1, 1609.1.1.1, 2308.2.1
IECC—09 International Energy Conservation Code® 101.4.6, 1203.3.2, 1301.1.1
IFC—09 International Fire Code® 101.4.5, 102.6, 201.3, 307.1, Table 307.1(1), Table 307.1(2), 307.1.1, 307.2, 403.4.4, 404.2, 406.5.1, 406.6.1, 410.3.6, 411.1, 412.1, 412.6.1, 413.1, 414.1.1, 414.1.2, 414.1.2.1, 414.2, 414.2.5, Table 414.2.5(1), Table 414.2.5(2), 414.3, 414.5, 414.5.1, Table 414.5.1, 414.5.2, 414.5.4, 414.5.5, 414.6, 415.1, 415.2, 415.3, 415.3.1, Table 415.3.1, Table 415.3.2, 415.6, 415.6.1, 415.6.1.4, 415.6.2, 415.6.2.3, 415.6.2.5, 415.6.2.7, 415.6.2.8, 415.6.2.9, 415.6.3, 415.6.4, 415.7, 415.8.1, 415.8.2.7, 415.8.5.1, 415.8.7.2, 415.8.9.3, 415.8.10.1, 416.1, 421.1, 421.7, 507.3, 707.1, 901.2, 901.3, 901.5, 901.6.2, 903.2.7.1, Table 903.2.11.6, 903.2.12 903.5, 904.2.1, 905.1, 905.3.6, 906.1, 907.1.8, 907.2.5, 907.2.13.2, 907.2.15, 907.2.16, 907.6.5, 907.8, 909.20, 910.2.2, 1001.3, 1203.4.2, 1203.5, 2702.1, 2702.2.9, 2702.2.11, 2702.2.12, 2702.2.13, 2702.3, 3102.1, 3103.1, 3309.2, 3401.3, 3412.3.2, 3412.6.8.1, 3412.6.14, 3412.6.14.1
IFGC—09 International Fuel Gas Code® 101.4.1, 201.3, Table 307.1(1), 415.6.3, 2113.11.1.2, 2113.15, 2801.1, 3401.3, A101.2
IMC—09 International Mechanical Code® 101.4.2, 201.3, 307.1, Table 307.1(1), 406.4.2, 406.6.3, 406.6.5, 409.3, 412.6.6, 414.1.2, 414.3, 415.6.1.4, 415.6.2, 415.6.2.8, 415.6.3, 415.6.4, 415.8.11.1, 416.3, 421.5, 603.1, 603.1.1, 603.1.2, 708.2, 716.2.2, 716.5.4, 716.6.1, 716.6.2, 716.6.3, 717.5, 719.1, 719.7, 903.2.11.4, 904.2.1, 904.11, 908.6, 909.1, 909.10.2, 1015.5, 1018.5.1, 1203.1, 1203.2.1, 1203.4.2, 1203.4.2.1, 1203.5, 1209.3, 2304.5, 2801.1, 3004.3.1, 3401.3, 3412.6.7.1, 3412.6.8, 3412.6.8.1, A101.2
IPC—09 International Plumbing Code® 101.4.3, 201.3, 415.6.4, 717.5, 903.3.5, 912.5, 1206.3.3, 1503.4, 1805.4.3, 2901.1, Table 2902.1, 3305.1, 3401.3, A101.2
IPMC—09 International Property Maintenance Code® . 101.4.4, 102.6, 103.3, 3401.3, 3412.3.2
IPSDC—09 International Private Sewage Disposal Code® 101.4.3, 2901.1, 3401.3
IRC—09 International Residential Code® 101.2, 308.2, 308.5, 310.1, 2308.1, 3401.3
IWUIC—09 International Wildland-Urban Interface Code™ Table 1505.1
SBCCI SSTD 11—97 Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles 1716.2.1, 1716.2.2
     
ISO International Organization for Standardization
ISO Central Secretariat
1 ch, de la Voie-Creuse, Case Postale 56
CH-1211 Geneva 20, Switzerland 
 
Standard
reference number
Title Referenced in code section number
ISO 8115—86 Cotton Bales—Dimensions and Density Table 415.8.2.1.1
     
NAAMM National Association of Architectural Metal Manufacturers
800 Roosevelt Road, Bldg. C, Suite 312
Glen Ellyn, IL 60137 
 
Standard
reference number
Title Referenced in code section number
FP 1001—97 Guide Specifications for Design of Metal Flag Poles 1609.1.1
     
NCMA National Concrete Masonry Association
13750 Sunrise Valley
Herndon, VA 22071-4662 
 
Standard
reference number
Title Referenced in code section number
TEK 5-84 (1996) Details for Concrete Masonry Fire Walls Table 720.1(2)
     
NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471 
 
Standard
reference number
Title Referenced in code section number
10—07 Portable Fire Extinguishers 906.2, 906.3.2, 906.3.4, Table 906.3(1), Table 906.3(2)
11—05 Low Expansion Foam 904.7
12—05 Carbon Dioxide Extinguishing Systems 904.8, 904.11
12A—04 Halon 1301 Halon 1301 Fire Extinguishing Systems 904.9
13—07 Installation of Sprinkler Systems 708.2, 903.3.1.1, 903.3.2, 903.3.5.1.1, 903.3.5.2, 904.11, 905.3.4, 907.6.3, 1613.6.3
13D—07 Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes 903.3.1.3, 903.3.5.1.1
13R—07 Installation of Sprinkler Systems in Residential Occupancies Up to and Including Four Stories in Height 903.3.1.2, 903.3.5.1.1, 903.3.5.1.2, 903.4
14—07 Installation of Standpipe and Hose System 905.2, 905.3.4, 905.4.2, 905.6.2, 905.8
16—07 Installation of Foam-water Sprinkler and Foam-water Spray Systems 904.7, 904.11
17—02 Dry Chemical Extinguishing Systems 904.6, 904.11
17A—02 Wet Chemical Extinguishing Systems 904.5, 904.11
20—07 Installation of Stationary Pumps for Fire Protection 913.1, 913.2.1, 913.5
30—08 Flammable and Combustible Liquids Code 415.3
31—06 Installation of Oil-burning Equipment 2113.15
32—07 Dry Cleaning Plants 415.6.4
40—07 Storage and Handling of Cellulose Nitrate Film 409.1
58—08 Liquefied Petroleum Gas Code 415.6.3
61—08 Prevention of Fires and Dust Explosions in Agricultural and Food Product Facilities 415.6.1
70—08 National Electrical Code 108.3, 415.8.2.8.2, 904.3.1, 907.6.1, 909.12.1, 909.16.3, 1205.4.1, 2701.1, 3401.3, H106.1, H106.2, K101, K111.1
72—07 National Fire Alarm Code 901.6, 903.4.1, 904.3.5, 907.2, 907.2.5, 907.2.11, 907.2.13.2, 907.3, 907.3.3, 907.3.4, 907.5.2.1.2, 907.5.2.2, 907.6, 907.6.1, 907.6.5, 907.7, 907.7.1, 907.7.2, 911.1.5, 3006.5, 3007.6
80—07 Fire Doors and Other Opening Protectives 410.3.5, 508.2.5.2, 715.4, 715.4.5, 715.4.6, 715.4.7.1, 715.4.8.2, 715.5, 715.5.5, 1008.1.4.3
85—07 Boiler and Combustion System Hazards Code 415.6.1 (Note: NFPA 8503 has been incorporated into NFPA 85)
92B—05 Smoke Management Systems in Malls, Atria and Large Spaces 909.8
99—05 Standard for Health Care Facilities 407.9
101—06 Life Safety Code 1028.6.2
105—07 Standard for the Installation of Smoke Door Assemblies 405.4.2, 715.4.3.1, 909.20.4.1
110—05 Emergency and Standby Power Systems 2702.1
111—05 Stored Electrical Energy Emergency and Standby Power Systems 2702.1
120—04 Coal Preparation Plants 415.6.1
170—06 Standard for Fire Safety and Emergency Symbols 1024.2.6.1
211—06 Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 2112.5
252—03 Standard Methods of Fire Tests of Door Assemblies 715.3, 715.4.1, 715.4.2, 715.4.3, 715.4.7.3.1
253—06 Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source 402.12.1, 406.6.4, 804.2, 804.3
257—07 Standard for Fire Test for Window and Glass Block Assemblies 715.3, 715.4.3.2, 715.5, 715.5.1, 715.5.2, 715.5.9.1
259—03 Test Method for Potential Heat of Building Materials 2603.4.1.10, 2603.5.3
265—07 Method of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall Coverings on Full Height Panels and Walls 803.1.3, 803.1.3.1
268—07 Standard Test Method for Determining Ignitibility of Exterior Wall Assemblies Using a Radiant Heat Energy Source 1406.2.1, 1406.2.1.1, 1406.2.1.2, 2603.5.7, D105.1
285—06 Standard Method of Test for the Evaluation of Flammability Characteristics of Exterior Nonload-bearingWall Assemblies Containing Combustible Components 1407.10.4, 2603.5.5
286—06 Standard Method of Fire Test for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth 402.16.4, 803.1.2, 803.1.2.1, 803.9, 2603.4, 2603.9
288—07 Standard Method of Fire Tests of Floor Fire Door Assemblies Installed Horizontally in Fire-resistance-rated Floor Systems 712.8
409—04 Aircraft Hangars 412.4.6, Table 412.4.6, 412.4.6.1, 412.6.5
418—06 Standard for Heliports 412.7.4
484—06 Combustible Metals 415.6.1
654—06 Prevention of Fire & Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids 415.6.1
655—07 Prevention of Sulfur Fires and Explosions 415.6.1
664—07 Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities 415.6.1
701—04 Standard Methods of Fire Tests for Flame-propagation of Textiles and Films 402.12.1, 410.3.6, 801.1.4, 806.1, 806.1.2, 806.2, 3102.3, 3102.3.1, 3102.6.1.1, 3105.4, D102.2.8, H106.1.1
704—07 Standard System for the Identification of the Hazards of Materials for Emergency Response 414.7.2, 415.2
1124—06 Manufacture, Transportation and Storage of Fireworks and Pyrotechnic Articles 415.3.1
2001—08 Clean Agent Fire Extinguishing Systems 904.10
     
PCI Precast Prestressed Concrete Institute 209 W. Jackson Boulevard, Suite 500 Chicago, IL 60606-6938
Standard
reference number
Title Referenced in code section number
MNL 124—89 Design for Fire Resistance of Precast Prestressed Concrete 721.2.3.1
MNL 128—01 Recommended Practice for Glass Fiber Reinforced Concrete Panels 1903.2
     
PTI Post-Tensioning Institute
8601 North Black Canyon Highway, Suite 103
Phoenix, AZ 85021 
 
Standard
reference number
Title Referenced in code section number
PTI—2007 Standard Requirements for Analysis of Shallow Concrete Foundations on Expansive Soils, Third Edition 1808.6.2
PTI—2007 Standard Requirements for Design of Shallow Post-tensioned Concrete Foundation on Expansive Soils, Second Edition 1808.6.2
     
RMI Rack Manufacturers Institute
8720 Red Oak Boulevard, Suite 201
Charlotte, NC 28217 
 
Standard
reference number
Title Referenced in code section number
ANSI/MH16.1—08 Specification for Design, Testing and Utilization of Industrial Steel Storage Racks 2208.1
     
SDI Steel Deck Institute
P. O. Box 25
Fox River Grove, IL 60021 
 
Standard
reference number
Title Referenced in code section number
ANSI/NC1.0—06 Standard for Noncomposite Steel Floor Deck 2209.2.2, 2209.2.2.1
ANSI/RD1.0—06 Standard for Steel Roof Deck 2209.2.3
     
SJI Steel Joist Institute
1173B London Links Drive
Forest, VA 24551 
 
Standard
reference number
Title Referenced in code section number
CJ-1.0—06 Standard Specification for Composite Steel Joists, CJ-series 1604.3.3, 2203.2, 2206.1
JG-1.1—05 Standard Specification for Joist Girders 1604.3.3, 2203.2, 2206.1
K-1.1—05 Standard Specification for Open Web Steel Joists, K-series 1604.3.3, 2203.2, 2206.1
LH/DLH-1.1—05 Standard Specification for Longspan Steel Joists, LH-series and Deep Longspan Steel Joists, DLH-series 1604.3.3, 2203.2, 2206.1
     
SPRI Single-Ply Roofing Institute
411 Waverly Oaks Road, Suite 331B
Waltham, MA 02452 
 
Standard
reference number
Title Referenced in code section number
SPRI/ANSI/ES-1—03 Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems 1504.5
RP-4—02 Wind Design Guide for Ballasted Single-ply Roofing Systems 1504.4
     
TIA Telecommunications Industry Association
2500 Wilson Boulevard
Arlington, VA 22201-3834 
 
Standard
reference number
Title Referenced in code section number
TIA-222-G—05 Structural Standards for Steel Antenna Towers and Antenna Supporting Structures including-Addendum 1, 222-G-1, Dated 2007 1609.1.1, 3108.1, 3108.2
     
TMS The Masonry Society
3970 Broadway, Unit 201-D
Boulder, CO 80304-1135 
 
Standard
reference number
Title Referenced in code section number
0216—97 Standard Method for Determining Fire Resistance of Concrete and Masonry Construction Assemblies Table 720.1(2), 721.1
0302—07 Standard Method for Determining the Sound Transmission Class Rating for Masonry Walls 1207.2.1
402—08 Building Code Requirements for Masonry Structures 1405.6, 1405.6.2, 1405.10, 1604.3.4, Table 1703.4.5.3, 1704.5, 1704.5.1, Table 1704.5.1, 1704.5.2, 1704.5.3, 1807.1.6.3.2, 1808.9, 2101.2.2, 2101.2.3, 2101.2.4, 2101.2.5, 2101.2.6, 2103.1.3.6, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4, 2107.5, 2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2109.3, 2110.1
602—08 Specification for Masonry Structures 1405.6.1, Table 1704.5.1, Table 1704.5.3, 1807.1.6.3, 2103.8, 2103.11, 2103.12, 2103.13, 2104.1, 2104.1.1, 2104.1.2 2104.1.3, 2104.2, 2104.3, 2104.4, 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3
     
TPI Truss Plate Institute
218 N. Lee Street, Suite 312
Alexandria, VA 22314 
 
Standard
reference number
Title Referenced in code section number
TPI 1—2007 National Design Standards for Metal-plate-connected Wood Truss Construction 2303.4.6, 2306.1
     
UL Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096 
 
Standard
reference number
Title Referenced in code section number
9—2000 Fire Tests of Window Assemblies—with Revisions through April 2005 715.3, 715.4.3.2, 715.5, 715.5.1, 715.5.2, 715.5.9.1
10A—98 Tin Clad Fire Doors—with Revisions through March 2003 715.4
10B—97 Fire Tests of Door Assemblies—with Revisions through October 2001 715.4.2
10C—98 Positive Pressure Fire Tests of Door Assemblies—with Revisions through November 2001 715.4.1, 715.4.3
14B—98 Sliding Hardware for Standard Horizontally-mounted Tin Clad Fire Doors— with Revisions through July 2000 715.4
14C—06 Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs 715.4
103—01 Factory-built Chimneys, for Residential Type and Building Heating Appliances— with Revisions through June 2006 717.2.5.1
127—96 Factory-built Fireplaces—with Revisions through November 2006 717.2.5.1, 2111.11
199E—04 Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers 904.11.4.1
217—06 Single and Multiple Station Smoke Alarms—with Revisions through August 2005 907.2.11
263—03 Standard for Fire Test of Building Construction and Materials 703.2, 703.2.1, 703.2.3, 703.3, 703.5, 704.12, 705.7, 707.7, 712.3.2, 713.3.1, 713.4.1.1, 714.1, 715.2, 716.5.2, 716.5.3, 716.6.1, Table 716.6.2(1), Table 720.1(1), 1407.10.2, 2103.2, 2603.4, 2603.5.1
268—06 Smoke Detectors for Fire Protective Signaling Systems—with Revisions through January 1999 407.7, 907.2.6.2
300—05 Fire Testing of Fire Extinguishing Systems for Protection of Restaurant Cooking Areas 904.11
305—07 Panic Hardware 1008.1.10
325—02 Door, Drapery, Gate, Louver and Window Operations and Systems— with Revisions through February 2006 406.1.5, 3110.4
555—2006 Fire Dampers 716.3
555C—2006 Ceiling Dampers 716.3, 716.6.2
555S—99 Smoke Dampers—with Revisions through July 2006 716.3, 716.3.1.1
580—2006 Test for Uplift Resistance of Roof Assemblies 1504.3.1, 1504.3.2
641—95 Type L Low-temperature Venting Systems—with Revisions through August 2005 2113.11.1.4
710B—04 Recirculating Systems—with Revisions through April 2006 904.11
723—03 Standard for Test for Surface Burning Characteristics of Building Materials— with Revisions through May 2005 402.11, 402.16.4, 406.5.3, 703.4.2, 719.1, 719.4, 802.1, 803.1.1, 803.9, 806.5, 1407.9, 1407.10.1, 2303.2, 2603.3, 2603.4.1.13, 2603.5.4, 2604.2.4, 2606.4, 3105.4, D102.2.8
790—04 Standard Test Methods for Fire Tests of Roof Coverings 1505.1, 2603.6, 2610.2, 2610.3
793—03 Standards for Automatically Operated Roof Vents for Smoke and Heat— with Revisions through April 2004 910.3.1
864—03 Standards for Control Units and Accessories for Fire Alarm Systems— with Revisions through March 2006 909.12
924—06 Standard for Safety Emergency Lighting and Power Equipment 1011.4
1040—96 Fire Test of Insulated Wall Construction—with Revisions through June 2001 1407.10.3, 2603.4, 2603.9
1256—02 Fire Test of Roof Deck Construction—with Revisions through January 2007 l508.1, 2603.3, 2603.4.1.5
1479—03 Fire Tests of Through-penetration Firestops—with Revisions through April 2007 .702.1, 713.3.1.2, 713.3.2, 713.4.1.1.2
1482—96 Solid-fuel-type Room Heater—with Revisions through November 2006 2112.2, 2112.5
1715—97 Fire Test of Interior Finish Material—with Revisions through March 2004 1407.10.2, 1407.10.3, 2603.4, 2603.9
1777—04 Chimney Liners 2113.11.1, 2113.19
1784—01 Air Leakage Tests of Door Assemblies—with Revisions through December 2004 708.14.1, 711.5.2, 715.4.3.1, 715.4.6.1, 715.4.6.3, 3007.4.3
1897—04 Uplift Tests for Roof Covering Systems 1504.3.1
1975—06 Fire Test of Foamed Plastics Used for Decorative Purposes 402.11, 402.12.1, 402.16.5
1994—04 Standard for Luminous Egress Path Marking Systems—with Revisions through February 2005 411.7, 1024.2.1, 1024.2.3, 1024.2.4, 1024.4
2017—2000 Standards for General-purpose Signaling Devices and Systems— with Revisions through August 2005 3109.4.1.8
2075—2007 Standard for Gas and Vapor Detectors and Sensors 406.6.6.1
2079—04 Tests for Fire Resistance of Building Joint Systems—with Revisions through March 2006 702.1, 714.3, 714.6
2200—04 Stationary Engine Generator Assemblies—with Revisions through July 2004 2702.1.1
     
ULC Underwriters Laboratories of Canada
7 Underwriters Road
Toronto, Ontario, Canada M1R3B4 
 
Standard
reference number
Title Referenced in code section number
CAN/ULC S102.2—1988 Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings and Miscellaneous Materials and Assemblies—with 2000 Revisions 719.4
     
USC United States Code
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325 
 
Standard
reference number
Title Referenced in code section number
18 USC Part 1, Ch.40 Importation, Manufacture, Distribution and Storage of Explosive Materials 307.2
     
WDMA Window and Door Manufacturers Association
1400 East Touhy Avenue #470
Des Plaines, IL 60018 
 
Standard
reference number
Title Referenced in code section number
AAMA/WDMA/CSA 101/I.S.2/A440—08 Specifications for Windows, Doors and Unit Skylights 1715.5.1, 2405.5
     
WRI Wire Reinforcement Institute, Inc.
942 Main Street, Suite 300 Hartford, CT 06103 
 
Standard
reference number
Title Referenced in code section number
WRI/CRSI—81 Design of Slab-on-ground Foundations—with 1996 Update 1808.6.2
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING