• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

84-20 Zone B

NYC Zoning Resolution > VIII Special Purpose Districts > 4 - Special Battery Park City District (BPC) > 84-20 Zone B
JUMP TO FULL CODE CHAPTER

Zone B is designed to provide for commercial and mixed development with ancillary retail and service uses, in accordance with the Large Scale Commercial Development Plan which is attached as an exhibit to the Master Lease for Battery Park City dated June 6, 1980, as amended. Alignment of the pedestrian bridge at Liberty Street shall connect or allow for connection at the easterly line of West Street with a pedestrian connection to be provided on the southerly side of Liberty Street, as provided in this Section. In addition, the pedestrian bridge at the World Trade Center crossing shall connect or allow for connection with the World Trade Center at the easterly line of West Street. The pedestrian bridges are shown on the District Plan in Appendix 1.

Related Code Sections


1609.6.2.1.1 Structural Design, Minimum Pressures
The load effects of the design wind pressures from Section 1609.6.2.1 shall not be less than assuming the pressures, p s , for Zones A, B, C and D ...
NYC Building Code 2014 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods > 1609.6.2 Simplified Design Procedure I (For Low-Rise Buildings) > 1609.6.2.1 Main Wind Force-Resisting System > 1609.6.2.1.1 Minimum Pressures
1609.6.2.1.1 Structural Design, Minimum Pressures
The load effects of the design wind pressures from Section 1609.6.2.1 shall not be less than assuming the pressures, p s , for Zones A, B, C ...
NYC Building Code 2008 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods > 1609.6.2 Simplified Design Procedure-I (For Low-Rise Buildings) > 1609.6.2.1 Main Wind Force-Resisting System > 1609.6.2.1.1 Minimum Pressures
Article 14 Elevators [PDF] (page 23)
is within the landing zone. b. Emergency unlocking devices shall not be provided which will unlock or release from the landing side any hoistway door ...
NYC 1938 Code [PDF] > 14 Elevators
1609.6 Structural Design, Simplified Wind Load Methods
in Figure 1609.6.2.1. For the horizontal pressures (Zones A, B, C, D), p s is the combination of the windward and leeward net pressures. p s shall ...
NYC Building Code 2014 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods
907.2.2 Fire Protection Systems, Group B
A manual and automatic fire alarm system shall be installed in Group B occupancies that are protected by an automatic sprinkler system where one ...
NYC Building Code 2014 > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required > 907.2.2 Group B
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE