602.1.1 zEPI
Go To Full Code Chapter
Performance-based designs shall demonstrate a zEPI of not more than 51 as determined in accordance with Equation 6-1 for energy use reduction and shall demonstrate a CO2e emissions reduction in accordance with Section 602.2 and Equation 6-2 for CO2e.
zEPI = 57 × (EUIp/EUI) | (Equation 6-1) |
where:
EUIp | = | the proposed energy use index in source kBtu/sf-y for the proposed design of the building and its site calculated in accordance with Section 602.1.2. |
EUI | = | the base annual energy use index in source kBtu/sf-y for a baseline building and its site calculated in accordance with Section 602.1.2. |
Related Code Sections
602.1.1 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, zEPI
Performance-based designs shall demonstrate a zEPI of not more than 51 as determined in accordance with Equation 6-1 for energy use reduction ...
302.1.1 Jurisdictional Requirements and Life Cycle Assessment, zEPI of 46 or Less
Where a zEPI of 46 or less is indicated by the jurisdiction in Table 302.1, buildings shall comply on a performance-basis in accordance with Section ...
A106.1 Project Electives, zEPI Reduction Project Electives
Project electives for buildings pursuing performance-based compliance in accordance with Section 601.3.1 shall be in accordance with the portions ...
1007.3.3.1 Existing Buildings, Annual Net Energy Use
The zEPI associated with the operation of the building and the buildings on the site, as determined in accordance with Section 602.1, shall ...
302.1 Jurisdictional Requirements and Life Cycle Assessment, Requirements Determined by the Jurisdiction
, the jurisdiction shall indicate a zEPI of 46 or less in Table 302.1 for each occupancy required to have enhanced energy performance.
Where "Yes" or "No" boxes ...