1910.28(b)(13) Work on Low-Slope Roofs
Go To Full Code Chapter
1910.28(b)(13)(i)
When work is performed less than 6 feet (1.6 m) from the roof edge, the employer must ensure each employee is protected from falling by a guardrail system, safety net system, travel restraint system, or personal fall arrest system.
1910.28(b)(13)(iii)
When work is performed 15 feet (4.6 m) or more from the roof edge, the employer must:
1910.28(b)(13)(iii)(A)
Protect each employee from falling by a guardrail system, safety net system, travel restraint system, or personal fall arrest system or a designated area. The employer is not required to provide any fall protection, provided the work is both infrequent and temporary; and
1910.28(b)(13)(iii)(B)
Implement and enforce a work rule prohibiting employees from going within 15 feet (4.6 m) of the roof edge without using fall protection in accordance with paragraphs (b)(13)(i) and (ii) of this section.
1910.28(b)(13)(ii)
When work is performed at least 6 feet (1.6 m) but less than 15 feet (4.6 m) from the roof edge, the employer must ensure each employee is protected from falling by using a guardrail system, safety net system, travel restraint system, or personal fall arrest system. The employer may use a designated area when performing work that is both infrequent and temporary.
Related Code Sections
1910.28(b)(13) Walking-Working Surfaces, Work on Low-Slope Roofs
When work is performed less than 6 feet (1.6 m) from the roof edge, the employer must ensure each employee is protected from falling by a guardrail ...
1910.266(d)(6) Special Industries, Work Areas
felled. The distance between adjacent occupied work areas shall reflect the degree of slope, the density of the growth, the height of the trees, the soil ...
1910.21 Walking-Working Surfaces, Scope and Definitions
consists of a carrier, safety sleeve, lanyard, connectors, and body harness. Cages and wells are not ladder safety systems.
Low-slope roof means ...
1910.66(h)(5) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, Roof Systems
Roof track systems, tie-downs, or similar equipment shall be maintained in proper working order so that they perform the function for which they were ...
1910.21(b) Walking-Working Surfaces, Definitions
systems.
Low-slope roof means a roof that has a slope less than or equal to a ratio of 4 in 12 (vertical to horizontal).
Lower level means ...