• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2319.7 Wood Entering Masonry or Reinforced Concrete

2020 FBC - Building, 7th edition > 23 Wood > 2319 High-Velocity Hurricane Zones—Horizontal Framing > 2319.7 Wood Entering Masonry or Reinforced Concrete
JUMP TO FULL CODE CHAPTER

2319.7.1

Wood joists, beams or girders which frame into masonry or reinforced concrete shall have a minimum of 1/2-inch (12.7 mm) air space at the top, end and sides or shall be preservative pressure treated or of an approved durable species.

2319.7.2

Where masonry extends above such wood members, joists shall be fire-cut so the top edge does not enter the masonry more than 1 inch (25 mm) or shall be provided with wall plate boxes of self-releasing type or approved hangers.

2319.7.3

Reserved.

Related Code Sections


2319.7 Wood, Wood Entering Masonry or Reinforced Concrete
Wood joists, beams or girders which frame into masonry or reinforced concrete shall have a minimum of 1 / 2 -inch (12.7 mm) air space at the top ...
2020 FBC - Building, 7th edition > 23 Wood > 2319 High-Velocity Hurricane Zones—Horizontal Framing > 2319.7 Wood Entering Masonry or Reinforced Concrete
2319.7 Wood, Wood Entering Masonry or Reinforced Concrete
Wood joists, beams or girders which frame into masonry or reinforced concrete shall have a minimum of 1 / 2 -inch (12.7 mm) air space at the top ...
2017 FBC - Building, 6th edition > 23 Wood > 2319 High-Velocity Hurricane Zones— Horizontal Framing > 2319.7 Wood Entering Masonry or Reinforced Concrete
2319.7 Wood, Wood Entering Masonry or Reinforced Concrete
Wood joists, beams or girders which frame into masonry or reinforced concrete shall have a minimum of 1 / 2 -inch (12.7 mm) air space at the top ...
2014 FBC - Building, 5th edition > 23 Wood > 2319 High-Velocity Hurricane Zones— Horizontal Framing > 2319.7 Wood Entering Masonry or Reinforced Concrete
2319.7.1 Wood,
Wood joists, beams or girders which frame into masonry or reinforced concrete shall have a minimum of 1 / 2 -inch (12.7 mm) air space at the top ...
2014 FBC - Building, 5th edition > 23 Wood > 2319 High-Velocity Hurricane Zones— Horizontal Framing > 2319.7 Wood Entering Masonry or Reinforced Concrete > 2319.7.1
2319.7.3 Wood,
Reserved ...
2020 FBC - Building, 7th edition > 23 Wood > 2319 High-Velocity Hurricane Zones—Horizontal Framing > 2319.7 Wood Entering Masonry or Reinforced Concrete > 2319.7.3
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING