Wood columns shall be approved wood of natural decay resistance or approved pressure-preservative-treated wood.
Exceptions:
  1. Columns exposed to the weather or in basements where supported by concrete piers or metal pedestals projecting 1 inch (25 mm) above a concrete floor or 6 inches (152 mm) above exposed earth and the earth is covered by an approved impervious moisture barrier.
  2. Columns in enclosed crawl spaces or unexcavated areas located within the periphery of the building where supported by a concrete pier or metal pedestal at a height more than 8 inches (203 mm) from exposed earth and the earth is covered by an impervious moisture barrier.
  3. Deck posts supported by concrete piers or metal pedestals projecting not less than 1 inch (25 mm) above a concrete floor or 6 inches (152 mm) above exposed earth.

Related Code Sections

R317.1.4 Building Planning, Wood Columns
Wood columns shall be approved wood of natural decay resistance or approved pressure-preservative-treated wood. Exceptions: Columns exposed ...
R407.1 Foundations, Wood Column Protection
Wood columns shall be protected against decay as set forth in Section R317 ...
602.4.3 Types of Construction, Exterior Structural Members
Where a horizontal separation of 20 feet (6096 mm) or more is provided, wood columns and arches conforming to heavy timber sizes complying ...
2304.10.7 Wood, Framing Requirements
Wood columns and posts shall be framed to provide full end bearing. Alternatively, column-and-post end connections shall be designed to resist ...