Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

33-301 Within One Hundred Feet of Corners

NYC Zoning Resolution > III Commercial District Regulations > 3 - Bulk Regulations for Commercial or Community Facility Buildings in Commercial Districts > 33-30 Other Special Provisions for Rear Yards > 33-301 Within One Hundred Feet of Corners
JUMP TO FULL CODE CHAPTER

C1 C2 C3 C4 C5 C6 C7 C8

In all districts, as indicated, no rear yard shall be required within 100 feet of the point of intersection of two street lines intersecting at an angle of 135 degrees or less.

Related Code Sections


§27-480 Special Uses and Occupancies, Curb Cuts
in length, and there shall not be more than two curb cuts on any street frontage of one hundred feet or less. The minimum distance between two curb cuts ...
NYC 1968 Code (Vol I) > 7 Special Uses and Occupancies > 13 Open Parking Lots > §27-480 Curb Cuts
406.7.6 Special Detailed Requirements Based on Use and Occupancy, Curb Cuts
not exceed 60 percent of any street frontage 100 feet (30 480 mm) or less in length. No single curb cut shall exceed 30 feet (9144 mm) in length ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor Vehicle-Related Occupancies > 406.7 Open Parking Lots > 406.7.6 Curb Cuts
912.2.1.5 Fire Protection Systems,
connection is located within 15 feet (4572 mm) of the corner and on the street with the longest building frontage or public space ...
NYC Building Code 2014 > 9 Fire Protection Systems > 912 Fire Department Connections > 912.2 Location > 912.2.1 Fire Department Connections > 912.2.1.5
406.7.6 Special Detailed Requirements Based on Use and Occupancy, Curb Cuts
mm) in length may be permitted. No curb cut shall commence within 8 feet (2438 mm) of a side lot line, except that on corner lots and lots ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies > 406.7 Open Parking Lots > 406.7.6 Curb Cuts
1305.14.3.2 Fuel-Oil Piping and Storage, Corners
Corners may be made up by bending the plates or by using angles ...
NYC Mechanical Code 2014 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.14 Alternate Tank Design and Construction Standards > 1305.14.3 Additional Construction Standards for Rectangular Tanks Exceeding 275 Gallon (1041 L) > 1305.14.3.2 Corners
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE