• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1414(b) Wire Rope Design Criteria:

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1414 Wire Rope--Selection and Installation Criteria > 1926.1414(b) Wire Rope Design Criteria:
JUMP TO FULL CODE CHAPTER
Wire rope (other than rotation resistant rope) must comply with either Option (1) or Option (2) of this section, as follows:

1926.1414(b)(1) Option (1)

Wire rope must comply with section 5-1.7.1 of ASME B30.5-2004 (incorporated by reference, see § 1926.6) except that section's paragraph (c) must not apply.

1926.1414(b)(2) Option (2)

Wire rope must be designed to have, in relation to the equipment's rated capacity, a sufficient minimum breaking force and design factor so that compliance with the applicable inspection provisions in § 1926.1413 will be an effective means of preventing sudden rope failure.

Related Code Sections


1926.1414(b) Cranes & Derricks in Construction, Wire Rope Design Criteria:
Wire rope must be designed to have, in relation to the equipment's rated capacity, a sufficient minimum breaking force ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1414 Wire Rope--Selection and Installation Criteria > 1926.1414(b) Wire Rope Design Criteria:
1926.451(d) Scaffolds, Criteria for Suspension Scaffolds
The use of repaired wire rope as suspension rope is prohibited ...
OSHA 1926 Construction > L Scaffolds > 1926.451 General Requirements > 1926.451(d) Criteria for Suspension Scaffolds
1926.251(c) Materials Handling, Storage, Use, and Disposal, Wire Rope
Employers must not use improved plow-steel wire rope and wire-rope slings with loads in excess of the rated capacities (i.e., working load limits ...
OSHA 1926 Construction > H Materials Handling, Storage, Use, and Disposal > 1926.251 Rigging Equipment for Material Handling > 1926.251(c) Wire Rope
1926.552(c)(14) Helicopters, Hoists, Elevators, and Conveyors, Ropes
Safety factors: Minimum Factors of Safety for Suspension Wire Ropes ...
OSHA 1926 Construction > N Helicopters, Hoists, Elevators, and Conveyors > 1926.552 Material Hoists, Personnel Hoists, and Elevators > 1926.552(c) Personnel Hoists > 1926.552(c)(14) Ropes
1926.1414(e)(2) Cranes & Derricks in Construction, Requirements
the wire rope manufacturer and the equipment manufacturer approves the design factor, in writing ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1414 Wire Rope--Selection and Installation Criteria > 1926.1414(e) Rotation Resistant Ropes > 1926.1414(e)(2) Requirements
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE