907.2.27 Winery Caves
JUMP TO FULL CODE CHAPTER
An approved manual fire alarm system conforming to the provisions of Section 907.2.1 shall be provided in all Type 3 winery caves.
Related Code Sections
907.2.27 Fire Protection Systems, Winery Caves
An approved manual fire alarm system conforming to the provisions of Section 907.2 shall be provided in all Type 3 winery caves ...
Los Angeles Building Code > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.27 Winery Caves
907.2.27 Fire Protection Systems, Winery Caves
An approved manual fire alarm system conforming to the provisions of Section 907.2.1 shall be provided in all Type 3 winery caves ...
2017 LA City Fire Code > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.27 Winery Caves
Section 446 Special Detailed Requirements Based on Use and Occupancy, Winery Caves [SFM]
The use of subterranean space for winery facilities in natural or manmade caves shall be in accordance with this section ...
Los Angeles Building Code > 4 Special Detailed Requirements Based on Use and Occupancy > 446 Winery Caves [SFM]
446.12 Special Detailed Requirements Based on Use and Occupancy, Exit Illumination
Exits shall be illuminated to a minimum intensity of not less than 1 foot-candle (10.76 lx) at floor level whenever the winery cave is occupied ...
Los Angeles Building Code > 4 Special Detailed Requirements Based on Use and Occupancy > 446 Winery Caves [SFM] > 446.12 Exit Illumination
446.7.2 Special Detailed Requirements Based on Use and Occupancy, Interior Construction
The walls and ceilings of winery caves shall not contain hidden or concealed spaces ...
Los Angeles Building Code > 4 Special Detailed Requirements Based on Use and Occupancy > 446 Winery Caves [SFM] > 446.7 Construction Requirements > 446.7.2 Interior Construction