• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3314.4.4.6 Winds

NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.4 Installation, Inspection, Repair, Maintenance, Adjustment, Use, and Removal of Scaffolds > 3314.4.4 Safeguards > 3314.4.4.6 Winds
JUMP TO FULL CODE CHAPTER
Where sustained winds or wind gusts at the site exceed 30 miles per hour, the use and operation of scaffolds located on the roof of a building, exterior to a building or structure, on a working deck, or in an area with an unenclosed perimeter shall cease. If the manufacturer or designer of the scaffold recommends work to cease at a lower wind speed, such recommendation shall instead apply. Wind speed shall be determined based on data from the nearest United States weather bureau reporting station, or an anemometer located at the site, freely exposed to the wind, and calibrated in accordance with ASTM D 5096-02.

Related Code Sections


3314.4.4.6 Safeguards During Construction or Demolition, Winds
Where sustained winds or wind gusts at the site exceed 30 miles per hour, the use and operation of scaffolds located on the roof of a building ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.4 Installation, Inspection, Repair, Maintenance, Adjustment, Use, and Removal of Scaffolds > 3314.4.4 Safeguards > 3314.4.4.6 Winds
*3113.4 Special Construction, Wind Speed
A small wind turbine shall be designed to withstand winds of up to and including 130 mph (58.1 m/s) or such higher wind load as may be specified ...
NYC Building Code 2014 > 31 Special Construction > *3113 Small Wind Turbines > *3113.4 Wind Speed
*3114.4 Special Construction, Wind Speed
A large wind turbine shall be designed to withstand winds of up to and including 130 mph (58.1 m/s) or such higher wind load as may be specified ...
NYC Building Code 2014 > 31 Special Construction > *3114 Large Wind Turbines > *3114.4 Wind Speed
*3319.13 Safeguards During Construction or Demolition, Measuring Wind
Wind speed during crane or derrick operations shall be determined in accordance with the requirements of Table 3319.13. Options 1, 2, and 3 in Table ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3319 Cranes and Derricks > *3319.13 Measuring Wind
102.4.2.3 Administration, Wind Resistance
For prior code buildings, equipment, appliances and supports that are exposed to wind shall be designed and installed to resist the wind pressures ...
NYC Plumbing Code 2014 > 1 Administration > 102 Applicability > 102.4 Additions, Alterations or Repairs > 102.4.2 Special Provisions for Prior Code Buildings > 102.4.2.3 Wind Resistance
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE