229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. Each glazed opening required by an administrative authority to be operable shall comply with 309.

EXCEPTION:
  1. Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with 229.
  2. Glazed openings in guest rooms required to provide communication features and in guest rooms required to comply with 206.5.3 shall not be required to comply with 229.

Related Code Sections

229 Scoping Requirements, Windows
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. Each glazed ...
216.10 Scoping Requirements, Assistive Listening Systems
with 703.7.2.4. EXCEPTION: Where ticket offices or windows are provided, signs shall not be required at each assembly area provided that signs ...
904.6 Built-in Elements, Security Glazing
Where counters or teller windows have security glazing to separate personnel from the public, a method to facilitate voice communication shall ...
307.2 Building Blocks, Protrusion Limits
  Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into circulation paths above 27 inches (685 mm). Figure ...