In Occupancy Group R-3, one- and two-family dwellings, where the opening of the sill portion of an operable window is located more than 72 inches (1829 mm) above the finished grade or other surface below, the lowest part of the clear opening of the window shall be at a height not less than 24 inches (610 mm) above the finished floor surface of the room in which the window is located. Glazing between the floor and a height of 24 inches (610 mm) shall be fixed or have openings through which a 4-inch (102 mm) diameter sphere cannot pass.

Exception: Openings that are provided with window guards that comply with ASTM F 2090.

Related Code Sections

1405.13.2 Exterior Walls, Window Sills in R-3 Occupancy
In Occupancy Group R-3, one- and two-family dwellings, where the opening of the sill portion of an operable window is located more than 72 inches ...
1015.8 Means of Egress, Window Sills in Group R-3 Occupancies
In one- and two-family dwellings, where the opening of the sill portion of an operable window is located more than 72 inches (1828.8 mm) above ...
501.3.2 General Building Heights and Areas; Separation of Occupancies, Building Access
- and two-family dwellings need not provide direct access. Any building classified in occupancy group R-2 not more than three stories in height ...
903.2.11.3 Fire Protection Systems, Other Below-Grade Stories
classified in Occupancy Group R-2 not more than three stories in height and with not more than two dwelling units on any story need not provide direct ...
903.2.11.3 Fire Protection Systems, Other Below-Grade Stories
classified in Occupancy Group R-2 not more than three stories in height and with not more than two dwelling units on any story need not provide direct ...