1709.5.3 Windborne Debris Protection
JUMP TO FULL CODE CHAPTER
Protection of exterior glazed openings in buildings located in windborne debris regions shall be in accordance with Section 1609.2.
Impact protective systems shall be tested for impact resistance by an approved independent laboratory for compliance with ASTM E1886 and ASTM E1996 and for design wind pressure for compliance with ASTM E330. Required design wind pressures shall be determined in accordance with ASCE 7, and for the purposes of this section, multiplied by 0.6 to convert to allowable stress design.
Impact protective systems shall have a permanent label applied in accordance with Section 1703.5.4, identifying the manufacturer, product designation, performance characteristics, and approved inspection agency.
Related Code Sections
1709.5.3 Special Inspections and Tests, Windborne Debris Protection
Protection of exterior glazed openings in buildings located in windborne debris regions shall be in accordance with Section 1609.2 ...
Building Code 2021 of Illinois > 17 Special Inspections and Tests > 1709 Preconstruction Load Tests > 1709.5 Exterior Window and Door Assemblies > 1709.5.3 Windborne Debris Protection
1609.2.3 Structural Design, Garage Doors
Garage door glazed opening protection for windborne debris shall meet the requirements of an approved impact-resisting standard or ANSI/DASMA 115 ...
Building Code 2018 of Illinois > 16 Structural Design > 1609 Wind Loads > 1609.2 Protection of Openings > 1609.2.3 Garage Doors
1609.2.3 Structural Design, Garage Doors
Garage door glazed opening protection for windborne debris shall meet the requirements of an approved impact-resisting standard or ANSI/DASMA 115 ...
Building Code 2021 of Illinois > 16 Structural Design > 1609 Wind Loads > 1609.2 Protection of Openings > 1609.2.3 Garage Doors
17.5.3.1.5 Initiating Devices,
of windborne debris. Space contains no equipment such as steam pipes, electric wiring, shafting, or conveyors. Floor over the space is tight. No ...
National Fire Alarm and Signaling Code 2019 of Illinois > 17 Initiating Devices > 17.5 Requirements for Smoke and Heat Detectors > 17.5.3* Detector Coverage > 17.5.3.1* Total (Complete) Coverage > 17.5.3.1.5
2407.1.4 Glass and Glazing, Glazing in Windborne Debris Regions
Glazing installed in in-fill panels or balusters in windborne debris regions shall comply with the following ...
Building Code 2018 of Illinois > 24 Glass and Glazing > 2407 Glass in Handrails and Guards > 2407.1 Materials > 2407.1.4 Glazing in Windborne Debris Regions