• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2306.2 Wind Provisions for Walls

2010 Building Code of NY > 23 Wood > 2306 Allowable Stress Design > 2306.2 Wind Provisions for Walls
JUMP TO FULL CODE CHAPTER

2306.2.1 Wall Stud Bending Stress Increase

The AF&PA; NDS fiber stress in bending (Fb) design values for sawn lumber wood studs resisting out of plane wind loads shall be increased by the factors in Table 2306.2.1, in lieu of the 1.15 repetitive member factor. These increases take into consideration the load sharing and composite actions provided by the wood structural panels as defined in Section 2302.1. The increases shall apply where the studs are designed for bending and are spaced no more than 16 inches (406 mm) o.c., covered on the inside with a minimum of 1/2 -inch (12.7 mm) gypsum board fastened in accordance with Table 2306.4.5 and sheathed on the exterior with a minimum of 3/8 -inch (9.5 mm) wood structural panel sheathing. All panel joints shall occur over studs or blocking and shall be attached using a minimum of 8d common nails spaced a maximum of 6 inches o.c. (152 mm) at panel edges and 12 inches o.c. (305 mm) at intermediate framing members.

TABLE 2306.2.1
WALL STUD BENDING STRESS INCREASE FACTORS
STUD SIZE SYSTEM FACTOR
2 × 4 1.5
2 × 6 1.35
2 × 8 1.25
2 × 10 1.2
2 × 12 1.15

Related Code Sections


2306.2 Wood, Wind Provisions for Walls
The AF&PA; NDS fiber stress in bending ( F b ) design values for sawn lumber wood studs resisting out of plane wind loads shall be increased ...
2010 Building Code of NY > 23 Wood > 2306 Allowable Stress Design > 2306.2 Wind Provisions for Walls
Section 2505 Gypsum Board and Plaster, Shear Wall Construction
and constructed in accordance with the materials and provisions of Section 2210.5 are permitted to resist wind and seismic loads. Walls resisting ...
2010 Building Code of NY > 25 Gypsum Board and Plaster > 2505 Shear Wall Construction
Section 2505 Gypsum Board, Gypsum Panel Products and Plaster, Shear Wall Construction
with Section 2306.3 and are permitted to resist wind and seismic loads. Walls resisting seismic loads shall be subject to the limitations in Section 12.2.1 ...
2020 Building Code of New York State > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2505 Shear Wall Construction
Section 2505 Gypsum Board, Gypsum Panel Products and Plaster, Shear Wall Construction
with Section 2306.3 and are permitted to resist wind and seismic loads. Walls resisting seismic loads shall be subject to the limitations in Section 12.2.1 ...
Building Code 2015 of New York State > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2505 Shear Wall Construction
R608.9 Wall Construction, Requirements for Connections—General
where cell is not shaded. Wall design per other provisions in Section R608 is required. For wind design, minimum 4-inch-nominal wall is permitted ...
Residential Code 2015 of New York State > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.9 Requirements for Connections—General
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE