Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R908.7 Wind Mitigation

2020 FBC - Residential, 7th edition > 9 Roof Assemblies > R908 Existing Roofing > R908.7 Wind Mitigation
JUMP TO FULL CODE CHAPTER
When a roof covering on an existing structure with a sawn lumber, wood plank or wood structural panel roof deck is removed and replaced, the following procedures shall be permitted to be performed by the roofing contractor:
  1. Roof-decking attachment shall be as required by Section R908.7.1.
  2. A secondary water barrier shall be provided as required by Section R908.7.2.
    Exception: Structures permitted subject to the Florida Building Code are not required to comply with this section.

R908.7.1 Roof Decking Attachment for Existing Structures With Wood Roof Decks

Fastening for sawn lumber, wood plank or wood structural panel roof decks shall be in accordance with Section R908.7.1.1 or R908.7.1.2 as appropriate for the existing construction. 8d nails shall be a minimum of 0.113 inch (2.9 mm) in diameter and shall be a minimum of 21/4 inch (57 mm) long to qualify for the provisions of this section for existing nails regardless of head shape or head diameter.

R908.7.1.1

Roof decking consisting of sawn lumber or wood planks up to 12 inches wide and secured with at least two nails (minimum size 8d) to each roof framing member it crosses shall be deemed to be sufficiently connected. Sawn lumber or wood plank decking secured with smaller fasteners than 8d nails or with fewer than two nails (minimum size 8d) to each framing member it crosses shall be deemed sufficiently connected if fasteners are added such that two clipped head, round head, or ring shank nails (minimum size 8d) are in place on each framing member it crosses.

R908.7.1.2

For roof decking consisting of wood structural panels, fasteners and spacing required in columns 3 and 4 of Table R908.7.1.2 are deemed to comply with the indicated design wind speed range. Wood structural panel connections retrofitted with a two part urethane based closed cell adhesive sprayed onto the joint between the sheathing and framing members are deemed to comply provided testing using the manufacturer's recommended application on panels connected with 6d smooth shank nails at no more than a 6-inch edge and 12-inch field spacing demonstrate an uplift resistance of a minimum of 200 psf.
Supplemental fasteners as required by Table R908.7.1.2 shall be ASTM F1667 classification RSRS-01 ring shank nails with the following minimum dimensions:
  1. 0.113-inch nominal shank diameter.
  2. Ring diameter a minimum of 0.012-inch greater than shank diameter.
  3. 16 to 20 rings per inch.
  4. A minimum 0.280-inch full round head diameter.
  5. Ring shank to extend a minimum of 11/2 inches from the tip of the nail.
  6. Minimum 21/4 inch nail length.
TABLE R908.7.1.2
SUPPLEMENT FASTENERS AT PANEL EDGES AND INTERMEDIATE FRAMING
EXISTING
FASTENERS
EXISTING
SPACING
Vasd 110 MPH OR
LESS
SUPPLEMENTAL
FASTENER
SPACING SHALL
BE NO GREATER
THAN
Vasd GREATER
THAN 110 MPH
SUPPLEMENTAL
FASTENER
SPACING
SHALL BE NO
GREATER THAN
Staples or 6d Any 6 inches o.c.b 6 inches o.c.b
8d clipped
head, round
head, smooth or
ring shank
6 inches
o.c. or
less
None necessary None necessary
8d clipped
head, round
head, smooth or
ring shank
Greater
than
6 inches
o.c.
6 inches o.c.a 6 inches o.c.a
For SI: 1 inch = 25.4 mm.
  1. Maximum spacing determined based on existing fasteners and supplemental fasteners.
  2. Maximum spacing determined based on supplemental fasteners only.
  3. Vasd shall be determined in accordance with Section 1609.3.1 of the Florida Building Code, Building or Section R301.2.1.3 of the Florida Building Code, Residential.

R908.7.2 Roof Secondary Water Barrier for Existing Structures With Wood Roof Decks

A secondary water barrier shall be installed using one of the following methods when roof covering is removed and replaced.
  1. In HVHZ regions:
    1. All joints in structural panel roof sheathing or decking shall be covered with a minimum 4 inch (102 mm) to 6 inch (153 mm) wide strip of self-adhering polymer modified bitumen tape applied directly to the sheathing or decking. The deck and self-adhering polymer modified bitumen tape shall be covered with one of the underlayment systems approved for the particular roof covering to be applied to the roof.
    2. The entire roof deck shall be covered with an approved asphalt impregnated 30# felt underlayment or approved synthetic underlayment installed with nails and tin-tabs in accordance with Section 1518.2, 1518.3 or 1518.4 of the Florida Building Code, Building. (No additional underlayment shall be required over the top of this sheet.) The synthetic underlayment shall be fastened in accordance with the manufacturer's recommendations.
  2. Outside the High-Velocity Hurricane Zone:
    1. Underlayment shall comply with Section R905.1.1 of the Florida Building Code, Residential.
Exceptions:
  1. Roof slopes < 2:12 having a continuous roof system shall be deemed to comply with Section R908.7.2 requirements for a secondary water barrier.
  2. Clay and concrete tile roof systems installed as required by the Florida Building Code, Residential are deemed to comply with the requirements of Section R908.7.2 for Secondary Water Barriers.

Related Code Sections


R908.7 Roof Assemblies, Wind Mitigation
panels, fasteners and spacing required in columns 3 and 4 of Table R908.7.1.2 are deemed to comply with the indicated design wind speed range. Wood ...
2020 FBC - Residential, 7th edition > 9 Roof Assemblies > R908 Existing Roofing > R908.7 Wind Mitigation
R908.7 Roof Assemblies, Wind Mitigation
, fasteners and spacing required in columns 3 and 4 of Table R908.7.1.2 are deemed to comply with the indicated design wind speed range. Wood structural ...
2017 FBC - Residential, 6th edition > 9 Roof Assemblies > R908 Existing Roofing > R908.7 Wind Mitigation
R908.7.1.2 Roof Assemblies,
with the indicated design wind speed range. Wood structural panel connections retrofitted with a two part urethane based closed cell adhesive sprayed ...
2017 FBC - Residential, 6th edition > 9 Roof Assemblies > R908 Existing Roofing > R908.7 Wind Mitigation > R908.7.1 Roof Decking Attachment for Site-Built Singlefamily Residential Structures > R908.7.1.2
R908.7.1.1 Roof Assemblies,
Roof decking consisting of sawn lumber or wood planks up to 12 inches wide and secured with at least two nails (minimum size 8d) to each roof framing ...
2020 FBC - Residential, 7th edition > 9 Roof Assemblies > R908 Existing Roofing > R908.7 Wind Mitigation > R908.7.1 Roof Decking Attachment for Existing Structures With Wood Roof Decks > R908.7.1.1
R908.7.1.2 Roof Assemblies,
with the indicated design wind speed range. Wood structural panel connections retrofitted with a two part urethane based closed cell adhesive sprayed ...
2020 FBC - Residential, 7th edition > 9 Roof Assemblies > R908 Existing Roofing > R908.7 Wind Mitigation > R908.7.1 Roof Decking Attachment for Existing Structures With Wood Roof Decks > R908.7.1.2
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING