Section P2720 Whirlpool Bathtubs

Jump To Full Code Chapter
P2720.1 Access to Pump
Access shall be provided to circulation pumps in accordance with the fixture or pump manufacturer's installation instructions. Where the manufacturer's instructions do not specify the location and minimum size of field-fabricated access openings, an opening of not less than 12 inches by 12 inches (305 mm by 305 mm) shall be installed for access to the circulation pump. Where pumps are located more than 2 feet (610 mm) from the access opening, an opening of not less than 18 inches by 18 inches (457 mm by 457 mm) shall be installed. A door or panel shall be permitted to close the opening. The access opening shall be unobstructed and be of the size necessary to permit the removal and replacement of the circulation pump.
P2720.2 Piping Drainage
The circulation pump shall be accessibly located above the crown weir of the trap. The pump drain line shall be properly graded to ensure minimum water retention in the volute after fixture use. The circulation piping shall be installed to be self-draining.
P2720.3 Leak Testing
Leak testing and pump operation shall be performed in accordance with the manufacturer's instructions.
P2720.4 Manufacturer's Instructions
The product shall be installed in accordance with the manufacturer's instructions.

Related Code Sections

Section 426 Fixtures, Faucets and Fixture Fittings, Whirlpool Bathtubs
Whirlpool bathtubs shall comply with ASME A112.19.7/CSA B45.10 and shall be listed and labeled in accordance with UL 1795 ...
Section P2720 Plumbing Fixtures, Whirlpool Bathtubs
Access shall be provided to circulation pumps in accordance with the fixture or pump manufacturer's installation instructions. Where ...
Section P2720 Plumbing Fixtures, Whirlpool Bathtubs
Access shall be provided to circulation pumps in accordance with the fixture or pump manufacturer's installation instructions. Where ...
412.5 Fixtures, Faucets and Fixture Fittings, Bathtub and Whirlpool Bathtub Valves
The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to not greater than 120°F (49°C) by a water-temperature limiting device ...
P2713.3 Plumbing Fixtures, Bathtub and Whirlpool Bathtub Valves
Bathtubs and whirlpool bathtub valves shall have or be supplied by a water-temperature-limiting device that conforms to ASSE 1070/ASME A112.1070/CSA ...