Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1101.15.1 Where Not Required

Uniform Plumbing Code 2018 of Nevada > 11 Storm Drainage > 1101.0 General > 1101.15 Traps on Storm Drains and Leaders > 1101.15.1 Where Not Required
JUMP TO FULL CODE CHAPTER
No trap shall be required for leaders or conductors that are connected to a sewer carrying storm water exclusively.

Related Code Sections


1101.15.1 Storm Drainage, Where Not Required
No trap shall be required for leaders or conductors that are connected to a sewer carrying storm water exclusively ...
Uniform Plumbing Code 2018 of Nevada > 11 Storm Drainage > 1101.0 General > 1101.15 Traps on Storm Drains and Leaders > 1101.15.1 Where Not Required
(B) Special Occupancies, Where GFCI Protection Is Not Required
not be required to be provided with GFCI protection. These receptacles shall be of the locking type ...
National Electrical Code 2017 of Nevada > 5 Special Occupancies > 525 Carnivals, Circuses, Fairs, and Similar Events > 525.23 Ground-Fault Circuit-Interrupter (GFCI) Protection > (B) Where GFCI Protection Is Not Required
414.5.1 Special Detailed Requirements Based on Occupancy and Use, Explosion Control
Where explosion hazards exist f Detonation Required Not Permitted Deflagration Not Required Required See Section 414.1.3 ...
Building Code 2018 of Nevada > 4 Special Detailed Requirements Based on Occupancy and Use > 414 Hazardous Materials > 414.5 Inside Storage, Dispensing and Use > 414.5.1 Explosion Control
414.5.1 Special Detailed Requirements Based on Use and Occupancy, Explosion Control
Where explosion hazards exist f Detonation Required Not Permitted Deflagration Not Required Required See Section 414.1.3 ...
Building Code 2012 of Nevada > 4 Special Detailed Requirements Based on Use and Occupancy > 414 Hazardous Materials > 414.5 Inside Storage, Dispensing and Use > 414.5.1 Explosion Control
625.15 Special Equipment, Markings
Where marking is required by 625.52(A), the equipment shall be clearly marked by the manufacturer ...
National Electrical Code 2017 of Nevada > 6 Special Equipment > 625 Electric Vehicle Charging System > 625.15 Markings
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING