• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

76-141 When Distance From Street Line Shown

NYC Zoning Resolution > VII Administration > 6 - Location of District Boundaries > 76-10 District Boundaries on the Zoning Maps > 76-14 Additional Rules of Construction > 76-141 When Distance From Street Line Shown
JUMP TO FULL CODE CHAPTER

In cases where the boundary line is shown by a dimension as being located a specific distance from a street line, this distance shall be considered to be measured from the nearest street line of the street from which dimensioned.

In cases where a Limited Height District boundary line appears to be identical or approximately identical with the boundary line of another district whose location is shown by a dimension, the boundary line of the Limited Height District shall be considered to be identical with the boundary line of the other district.

Related Code Sections


1027.3 Means of Egress, Exit Discharge Location
Exterior balconies, stairways and ramps shall be located at least 10 feet (3048 mm) from adjacent lot lines and from other buildings on the same lot ...
NYC Building Code 2014 > 10 Means of Egress > 1027 Exit Discharge > 1027.3 Exit Discharge Location
1023.3 Means of Egress, Exit Discharge Location
Exterior balconies, stairways and ramps shall be located at least 10 feet (3048 mm) from adjacent lot lines and from other buildings on the same lot ...
NYC Building Code 2008 > 10 Means of Egress > 1023 Exit Discharge > 1023.3 Exit Discharge Location
106.3 Administration, Lot Diagram
construction including parking and curb cuts; all existing structures on the zoning lot and their distances from lot and street lines; the established grade ...
NYC Building Code 2008 > 1 Administration > 106 Construction Documents > 106.3 Lot Diagram
107.3 Administration, Lot Diagram
construction including parking and curb cuts; all existing structures on the zoning lot and their distances from lot and street lines; the established grade ...
NYC Building Code 2014 > 1 Administration > 107 Construction Documents > 107.3 Lot Diagram
3202.2 Encroachments Into the Public Right-Of-Way, Encroachments Above Grade
, and other similar elements may be constructed: To project not more than 4 inches (102 mm) beyond the street line when less than 10 feet (3048 mm) above ...
NYC Building Code 2008 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.2 Encroachments Above Grade
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE