909.1 Wet Vent Permitted
JUMP TO FULL CODE CHAPTER
Any combination of fixtures within one bathroom group located in the same room are permitted to be vented by a wet vent. The wet vent shall be considered the vent for the fixtures and shall extend from the connection of the dry vent along the direction of the flow in the drain pipe to the most downstream fixture drain connection to the horizontal branch drain. Only the fixtures within the bathroom groups shall connect to the wet-vented horizontal branch drain. Any additional fixtures shall discharge downstream of the wet vent.
Related Code Sections
909.1 Vents, Wet Vent Permitted
Any combination of fixtures within one bathroom group located in the same room are permitted to be vented by a wet vent. The wet vent shall ...
909.1 Vents, Horizontal Wet Vent Permitted
Any combination of fixtures within one bathroom group located in the same room is permitted to be vented by a horizontal wet vent. The wet vent shall ...
909.3 Vents, Size
The dry vent serving the wet vent shall be sized based on the largest required diameter of pipe within the wet-vent system served by the dry vent ...