Welded wire fabric with wire size not greater than W5 or D5 used in slabs not exceeding 10 feet (3048 mm) in span is permitted to be curved from a point near the top of the slab over the support to a point near the bottom of the slab at midspan, provided such reinforcement is either continuous over, or securely anchored at support.
Upcodes Diagrams

Related Code Sections

1907.5.3 Concrete, Welded Wire Fabric
Welded wire fabric with wire size not greater than W5 or D5 used in slabs not exceeding 10 feet (3048 mm) in span is permitted to be curved from ...
2103.11.4 Masonry, Wire Fabric
Wire fabric shall conform to ASTM A 185 for plain steel-welded wire fabric for concrete reinforcement or ASTM A 496 for welded deformed steel wire ...
§27-630 Structural Work, Identification of Metal Reinforcement
Bundles or rolls of welded wire fabric shall be securely tagged so as to identify the type and grade of steel, and the size ...
§27-604 Structural Work, Identification of Metal-Reinforcement
Reinforcing bars shall be rolled so as to identify type and grade of steel, and size. Bundles and rolls of wire, strands, or welded wire fabric shall ...
2212.3 Steel, Composite Construction
Welded wire fabric reinforcement in concrete slabs shall be continuous over all supports and in all spans. Minimum area of continuous reinforcement ...