R703.7.2.1 Weep Screeds

Residential Code 2015 of Utah > 7 Wall Covering > R703 Exterior Covering > R703.7 Exterior Plaster > R703.7.2 Plaster > R703.7.2.1 Weep Screeds
JUMP TO FULL CODE CHAPTER
A minimum 0.019-inch (0.5 mm) (No. 26 galvanized sheet gage), corrosion-resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 31/2 inches (89 mm) shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C926. The weep screed shall be placed not less than 4 inches (102 mm) above the earth or 2 inches (51 mm) above paved areas and shall be of a type that will allow trapped water to drain to the exterior of the building. The weather-resistant barrier shall lap the attachment flange. The exterior lath shall cover and terminate on the attachment flange of the weep screed.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


2512.1.2 Gypsum Board, Gypsum Panel Products and Plaster, Weep screeds
A minimum 0.019-inch (0.48 mm) (No. 26 galvanized sheet gage), corrosion-resistant weep screed with a minimum vertical attachment flange of 3 1 / 2 ...
Building Code 2018 of Utah > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2512 Exterior Plaster > 2512.1 General > 2512.1.2 Weep screeds
2512.1.2 Gypsum Board, Gypsum Panel Products and Plaster, Weep Screeds
A minimum 0.019-inch (0.48 mm) (No. 26 galvanized sheet gage), corrosion-resistant weep screed with a minimum vertical attachment flange of 3 1 / 2 ...
Building Code 2015 of Utah > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2512 Exterior Plaster > 2512.1 General > 2512.1.2 Weep Screeds
R703.7.2.1 Wall Covering, Weep Screeds
A minimum 0.019-inch (0.5 mm) (No. 26 galvanized sheet gage), corrosion-resistant weep screed or plastic weep screed, with a minimum vertical ...
Residential Code 2015 of Utah > 7 Wall Covering > R703 Exterior Covering > R703.7 Exterior Plaster > R703.7.2 Plaster > R703.7.2.1 Weep Screeds
Section 2512 Gypsum Board, Gypsum Panel Products and Plaster, Exterior Plaster
26 galvanized sheet gage), corrosion-resistant weep screed with a minimum vertical attachment flange of 3 1 / 2 inches (89 mm) shall be provided ...
Building Code 2015 of Utah > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2512 Exterior Plaster
Section R703 Wall Covering, Exterior Covering
galvanized sheet gage), corrosion-resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 3 1 / 2 inches (89 mm) shall ...
Residential Code 2015 of Utah > 7 Wall Covering > R703 Exterior Covering
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US