R337.8.4 Weather Stripping
JUMP TO FULL CODE CHAPTER
Exterior garage doors shall
be provided with weather stripping to resist the intrusion
of embers from entering through gaps between doors and
door openings when visible gabs exceed 1/8-inch (3.2 mm).
Weather stripping or seals shall be installed on the bottom,
sides, and tops of doors to reduce gaps between
doors and door openings to 1/8-inch (3.2 mm) or less.
Related Code Sections
708A.4 [SFM] Materials and Construction Methods for Exterior Wildfire Exposure, Weather Stripping
Exterior garage doors shall be
provided with weather stripping to resist the intrusion of
embers from entering through gaps between doors and door ...
Los Angeles Building Code > 7A [SFM] Materials and Construction Methods for Exterior Wildfire Exposure > 708A Exterior Windows, Skylights and Doors > 708A.4 Weather Stripping
R337.8.4 Building Planning, Weather Stripping
Exterior garage doors shall
be provided with weather stripping to resist the intrusion
of embers from entering through gaps between doors and
door ...
Los Angeles Residential Code > 3 Building Planning > R337.8 Exterior Windows, Skylights and Doors > R337.8.4 Weather Stripping
R905.8.7 Roof Assemblies, Shake Placement
to the weather by positioning the lower edge of each felt strip above the butt end of the shake it covers a distance equal to twice the weather ...
Los Angeles Residential Code > 9 Roof Assemblies > R905 Requirements for Roof Coverings > R905.8 Wood Shakes > R905.8.7 Shake Placement
R905.8.7 Roof Assemblies, Shake Placement
to the weather by positioning the lower edge of each felt strip above the butt end of the shake it covers a distance equal to twice the weather ...
Los Angeles Residential Code > 9 Roof Assemblies > R905 Requirements for Roof Coverings > R905.8 Wood Shakes > R905.8.7 Shake Placement
1404.11.2 Exterior Walls, Weather Protection
strips or other wood supports for exterior metal veneer shall be approved pressure-treated wood or protected as required in Section 1402.2. Joints ...
Los Angeles Building Code > 14 Exterior Walls > 1404 Installation of Wall Coverings > 1404.11 Metal Veneers > 1404.11.2 Weather Protection