P2802.1 Water Temperature Control
JUMP TO FULL CODE CHAPTER
Where heated water is discharged from a solar thermal system to a hot water distribution system, a thermostatic mixing valve complying with ASSE 1017 shall be installed to temper the water to a temperature of not greater than 140°F (60°C). Solar thermal systems supplying hot water for both space heating and domestic uses shall comply with Section P2803.2. A temperature-indicating device shall be installed to indicate the temperature of the water discharged from the outlet of the mixing valve. The thermostatic mixing valve required by this section shall not be a substitute for water temperature limiting devices required by Chapter 27 for specific fixtures.
Related Code Sections
P2802.1 Water Heaters, Water Temperature Control
1017 shall be installed to temper the water to a temperature of not greater than 140°F (60°C). Solar thermal systems supplying hot water for both ...
2017 FBC - Residential, 6th edition > 28 Water Heaters > P2802 Solar Water Heating Systems > P2802.1 Water Temperature Control
P2802.1 Water Heaters, Water Temperature Control
1017 shall be installed to temper the water to a temperature of not greater than 140°F (60°C). Solar thermal systems supplying hot water for both ...
2020 FBC - Residential, 7th edition > 28 Water Heaters > P2802 Solar Water Heating Systems > P2802.1 Water Temperature Control
607.1.2 Water Supply and Distribution, Tempered Water Temperature Control
Tempered water shall be supplied through a water temperature limiting device that conforms to ASSE 1070 and shall limit the tempered water ...
2014 FBC - Plumbing, 5th edition > 6 Water Supply and Distribution > 607 Hot Water Supply System > 607.1 Where Required > 607.1.2 Tempered Water Temperature Control
607.1.2 Water Supply and Distribution, Tempered Water Temperature Control
Tempered water shall be supplied through a water temperature limiting device that conforms to ASSE 1070 and shall limit the tempered water ...
2017 FBC - Plumbing, 6th edition > 6 Water Supply and Distribution > 607 Hot Water Supply System > 607.1 Where Required > 607.1.2 Tempered Water Temperature Control
607.1.2 Water Supply and Distribution, Tempered Water Temperature Control
Tempered water shall be supplied through a water temperature limiting device that conforms to ASSE 1070 and shall limit the tempered water ...
2020 FBC - Plumbing, 7th edition > 6 Water Supply and Distribution > 607 Hot Water Supply System > 607.1 Where Required > 607.1.2 Tempered Water Temperature Control