• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1403.2 Water-Resistive Barrier

Building Code 2018 of Illinois > 14 Exterior Walls > 1403 Materials > 1403.2 Water-Resistive Barrier
JUMP TO FULL CODE CHAPTER
Not fewer than one layer of No.15 asphalt felt, complying with ASTM D226 for Type 1 felt or other approved materials, shall be attached to the studs or sheathing, with flashing as described in Section 1404.4, in such a manner as to provide a continuous water-resistive barrier behind the exterior wall veneer.

Related Code Sections


1402.5 Exterior Walls, Water-Resistive Barriers
a combustible water-resistive barrier shall be tested in accordance with and comply with the acceptance criteria of NFPA 285.Combustibility shall ...
Building Code 2021 of Illinois > 14 Exterior Walls > 1402 Performance Requirements > 1402.5 Water-Resistive Barriers
1403.2 Exterior Walls, Water-Resistive Barrier
Not fewer than one layer of  water-resistive barrier material shall be attached to the studs or sheathing, with flashing as described ...
Building Code 2021 of Illinois > 14 Exterior Walls > 1403 Materials > 1403.2 Water-Resistive Barrier
1403.2 Exterior Walls, Water-Resistive Barrier
to the studs or sheathing, with flashing as described in Section 1404.4, in such a manner as to provide a continuous water-resistive barrier behind ...
Building Code 2018 of Illinois > 14 Exterior Walls > 1403 Materials > 1403.2 Water-Resistive Barrier
1404.10.1.1 Exterior Walls, Water-Resistive Barriers
Water-resistive barriers shall be installed as required in Section 2510.6 ...
Building Code 2021 of Illinois > 14 Exterior Walls > 1404 Installation of Wall Coverings > 1404.10 Adhered Masonry Veneer > 1404.10.1 Exterior Adhered Masonry Veneer > 1404.10.1.1 Water-Resistive Barriers
1404.10.1.1 Exterior Walls, Water-Resistive Barriers
Water-resistive barriers shall be installed as required in Section 2510.6 ...
Building Code 2018 of Illinois > 14 Exterior Walls > 1404 Installation of Wall Coverings > 1404.10 Adhered Masonry Veneer > 1404.10.1 Exterior Adhered Masonry Veneer > 1404.10.1.1 Water-Resistive Barriers
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING