L 502.2 Water Heaters and Storage Tanks
JUMP TO FULL CODE CHAPTER
Residential-type water heaters, pool heaters, and unfired water heater storage tanks shall comply with the minimum performance requirements specified by federal law.
Unfired storage water heating equipment shall have a heat loss through the tank surface area of less than 6.5 British thermal units per square foot hour [Btu/(ft2•h)] (20.5 W/m2). [ASHRAE 90.2-2007:7.1]
Related Code Sections
L 502.2 Sustainable Practices, Water Heaters and Storage Tanks
Residential-type water heaters, pool heaters, and unfired water heater storage tanks shall comply with the minimum performance requirements specified ...
2021 Oregon Plumbing Specialty Code > L Sustainable Practices > L 502.0 Service Hot Water — Low-Rise Residential Buildings > L 502.2 Water Heaters and Storage Tanks
1402.8.5 Solar Thermal Systems, Water Heaters and Hot Water Storage Tanks
Auxiliary water heaters, boilers and water storage tanks associated with solar thermal systems shall comply with Chapter 10 and ICC 900/SRCC 300 ...
2019 Oregon Mechanical Specialty Code > 14 Solar Thermal Systems > 1402 Design and Installation > 1402.8 Equipment > 1402.8.5 Water Heaters and Hot Water Storage Tanks
P2801.4 Water Heaters, Location
Water heaters and storage tanks shall be installed in accordance with Section M1305 and shall be located and connected to provide access ...
7.4.6 Service Water Heating, Heat Traps
Vertical pipe risers serving storage water heaters and storage tanks not having integral heat traps and serving a nonrecirculating system shall have ...
2021 Oregon Energy Efficiency Specialty Code (OEESC) > 7 Service Water Heating > 7.4 Mandatory Provisions > 7.4.6 Heat Traps
L 503.3.7 Sustainable Practices, Heat Traps
Vertical pipe risers serving storage water heaters and storage tanks not having integral heat traps and serving a nonrecirculating system shall have ...
2021 Oregon Plumbing Specialty Code > L Sustainable Practices > L 503.0 Service Hot Water — Other Than Low-Rise Residential Buildings > L 503.3 Mandatory Provisions > L 503.3.7 Heat Traps