607.2.2 Water Heater Controls for Dwelling Units
JUMP TO FULL CODE CHAPTER
Water heaters installed in dwelling units in buildings shall be equipped with external water temperature thermostat controls.
The controls shall allow the occupant to set the water temperature at a setting that is below 100°F (38°C) and greater than or equal to 50°F (10°C).
Related Code Sections
607.2 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Service Water Heating (SWH) Equipment Performance Requirements
heaters installed in dwelling units in buildings shall be equipped with external water temperature thermostat controls. The controls shall allow ...
DC Green Construction Code 2013 > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 607 Building Service Water Heating Systems > 607.2 Service Water Heating (SWH) Equipment Performance Requirements
R403.5 [RE] Residential Energy Efficiency, Service Hot Water Systems
Piping serving more than one dwelling unit. Piping located outside the conditioned space. Piping from the water heater to a distribution manifold ...
DC Energy Conservation Code 2017 - Residential Provisions > 4 [RE] Residential Energy Efficiency > R403 Systems > R403.5 Service Hot Water Systems
N1103.5 [RE] Energy Efficiency, (R403.5) Service Hot Water Systems
Piping serving more than one dwelling unit. Piping located outside the conditioned space. Piping from the water heater to a distribution ...
DC Residential Code 2017 > 11 [RE] Energy Efficiency > N1103 (R403) Systems > N1103.5 (R403.5) Service Hot Water Systems
P2802.2 Water Heaters, Temperature Control
Where a combination water heater-space heating system requires water for space heating at temperatures exceeding 140°F (60°C), a master thermostatic ...
DC Residential Code 2013 > 28 Water Heaters > P2802 Water Heaters Used for Space Heating > P2802.2 Temperature Control
P2803.2 Water Heaters, Temperature Control
Where a combination water heater-space heating system requires water for space heating at temperatures exceeding 140°F (60°C), a master thermostatic ...
DC Residential Code 2017 > 28 Water Heaters > P2803 Water Heaters Used for Space Heating > P2803.2 Temperature Control