404.1.1 Water for Outdoor Landscape Irrigation
Go To Full Code Chapter
Outdoor landscape irrigation systems shall be designed and installed to reduce potable water use by 50 percent from a calculated mid-summer baseline in accordance with Section 404.1.2 or, where permitted by State regulation or local ordinances, the system shall be supplied by municipal reclaimed water or with alternate onsite nonpotable water complying with Chapter 7.
Exceptions: Potable water is permitted to be used as follows:
- During the establishment phase of newly planted landscaping.
- To irrigate food production.
- To supplement nonpotable water irrigation of shade trees provided in accordance with Section 408.2.3.
- Potable water is permitted for landscape irrigation where approved by local ordinance or regulation.
Upcodes Diagrams
Related Code Sections
404.1.1 Site Development and Land Use, Water for Outdoor Landscape Irrigation
Outdoor landscape irrigation systems shall be designed and installed to reduce potable water use by 50 percent from a calculated mid-summer baseline ...
404.1.2 Site Development and Land Use, Irrigation System Design and Installation
Landscape irrigation systems shall not direct water onto building exterior surfaces, foundations or exterior paved surfaces. Systems shall not generate runoff ...
404.2 Site Development and Land Use, Outdoor Ornamental Fountains and Water Features
be used for outdoor ornamental fountains and other water features constructed or installed on a building site. Where the fountain or water feature ...
709.5.1 Water Resource Conservation, Quality and Efficiency, Reclaimed Water for Landscape Irrigation
Reclaimed water used for landscape irrigation purposes shall be limited to subsurface applications. Reclaimed water used in irrigation systems shall ...