// CODE SNIPPET
P2906.5 Water Distribution Pipe
JUMP TO FULL CODE CHAPTER
Water distribution piping within dwelling units shall conform to NSF 61 and shall conform to one of the standards indicated in Table P2906.5. Water distribution pipe and tubing shall have a pressure rating of not less than 100 psi at 180°F (689 kPa at 82°C).
MATERIAL | STANDARD | |
---|---|---|
Chlorinated polyvinyl chloride (CPVC) plastic pipe and tubing | ASTM D2846; ASTM F441; ASTM F442/F442M; CSA B137.6 | |
Chlorinated polyvinyl chloride/aluminum/chlorinated polyvinyl chloride (CPVC/AL/CPVC) plastic pipe | ASTM F2855 | |
Copper or copper-alloy pipe | ASTM B42; ASTM B43; ASTM B302 | |
Copper or copper-alloy tubing (Type K, WK, L, WL, M or WM) | ASTM B75/B75M; ASTM B88; ASTM B251;ASTM B447 | |
Cross-linked polyethylene (PEX) plastic tubing | ASTM F876; CSA B137.5 | |
Cross-linked polyethylene/aluminum/cross-linked polyethylene (PEX-AL-PEX) pipe | ASTM F1281; ASTM F2262; CSA B137.10 | |
Cross-linked polyethylene/aluminum/high-density polyethylene (PEX-AL-HDPE) pipe | ASTM F1986 | |
Galvanized steel pipe | ASTM A53 | |
Polyethylene/aluminum/polyethylene (PE-AL-PE) composite pipe | ASTM F1282 | |
Polyethylene of raised temperature (PE-RT) plastic tubing | ASTM F2769; CSA B137.18 | |
Polypropylene (PP) plastic pipe or tubing | ASTM F2389; CSA B137.11 | |
Stainless steel (Type 304/304L) pipe | ASTM A312; ASTM A778 |
Related Code Sections
605.4 Water Supply and Distribution, Water Distribution Pipe
Water distribution pipe and tubing shall conform to NSF 61 and shall conform to one of the standards listed in Table 605.4. Hot water distribution ...
Plumbing Code 2018 of Kansas > 6 Water Supply and Distribution > 605 Materials, Joints and Connections > 605.4 Water Distribution Pipe
P2906.5 Water Supply and Distribution, Water Distribution Pipe
Water distribution piping within dwelling units shall conform to NSF 61 and shall conform to one of the standards indicated in Table P2906.5 ...
Residential Code 2018 of Kansas > 29 Water Supply and Distribution > P2906 Materials, Joints and Connections > P2906.5 Water Distribution Pipe
606.7 Water Supply and Distribution, Labeling of Water Distribution Pipes in Bundles
Where water distribution piping is bundled at installation, each pipe in the bundle shall be identified using stenciling or commercially available ...
Plumbing Code 2018 of Kansas > 6 Water Supply and Distribution > 606 Installation of the Building Water Distribution System > 606.7 Labeling of Water Distribution Pipes in Bundles
P2911.11 Water Supply and Distribution, Distribution Pipe
Distribution piping utilized in on-site nonpotable water reuse systems shall comply with Sections P2911.11.1 through P2911.11.3. Exception ...
Residential Code 2018 of Kansas > 29 Water Supply and Distribution > P2911 On-Site Nonpotable Water Reuse Systems > P2911.11 Distribution Pipe
1302.11 Nonpotable Water Systems, Distribution Pipe
Distribution piping utilized in on-site nonpotable water reuse systems shall comply with Sections 1302.11.1 through 1302.11.3. Exception ...
Plumbing Code 2018 of Kansas > 13 Nonpotable Water Systems > 1302 On-Site Nonpotable Water Reuse Systems > 1302.11 Distribution Pipe