62-211 Water-Dependent (WD) Uses
WD uses require direct access to a body of water in order to function or use waterways for transport of materials or products. WD uses shall be limited to the following:
From Use Group 4:
Non-profit private beach clubs
Non-profit private boat clubs
From Use Group 6:
*Docks for ferries, other than gambling vessels, limited as to passenger load (also listed in Use Group 14)
*Docks for water taxis (also listed in Use Group 14)
Docks or mooring facilities for non-commercial pleasure boats (also listed in Use Group 14)
Terminal facilities at river crossings for access to electric, gas or steam lines
From Use Group 7:
Boatels, provided that the units are predominantly occupied by persons with boats docked at the facility
From Use Group 9:
*Docks for sightseeing, excursion or sport fishing vessels, other than gambling vessels, limited as to dock capacity per zoning lot (also listed in Use Group 14)
From Use Group 10:
Docks for ferries, other than gambling vessels, with no restriction on passenger load
From Use Group 13:
Boat fuel sales establishments, open or enclosed, without restriction as to location
Commercial beaches
From Use Group 14:
Boat fuel sales establishments, open or enclosed, restricted to location within 10 feet of a boat dock berth
Boat launching facilities for non-commercial pleasure boats
Boat rental establishments, open or enclosed
*Boat storage, repair or painting establishments with size and location restrictions
From Use Group 16:
Boat sales establishments, open or enclosed
*Public transit yards, *trucking terminals, warehouses and *wholesale establishments, provided such uses ship or receive materials or products by water as evidenced by operational docking facilities on the zoning lot
From Use Group 17:
*Boat building or repair establishments, open or enclosed, for boats less than 200 feet in length
Docks for passenger ocean vessels, other than gambling vessels
Docks for sightseeing, excursion or sport fishing vessels, other than gambling vessels, with no restriction on vessel or dock capacity
Docks for vessels not otherwise listed, other than docks for gambling vessels
All other uses in Use Group 17 that ship or receive materials or products by water as evidenced by operational docking facilities on the zoning lot
From Use Group 18:
Marine transfer stations for garbage
Sewage disposal plants
Ship or boat building establishments or repair yards, for vessels 200 feet in length or over
All other uses in Use Group 18 that ship or receive materials or products by water as evidenced by operational docking facilities on the zoning lot
Other Uses:
Airports
Heliports
Seaplane bases
Uses accessory to the preceding listed uses
* Refer to Use Group for detailed description of this use