1910.262(i) Warpers
JUMP TO FULL CODE CHAPTER
—
Swiveled double-bar gates shall be installed on all warpers operating in excess of 450 yards per minute. These gates shall be so interlocked that the machine cannot be operated until the gate is in the "closed position," except for the purpose of inching or jogging.
Closed position shall mean that the top bar of the gate shall be at least 42 inches from the floor or working platform; and the lower bar shall be at least 21 inches from the floor or working platform; and the gate shall be located 15 inches from the vertical tangent to the beam head.
Related Code Sections
1910.262(b)(37) Special Industries, Warper
A warper is any machine for preparing and arranging the yarns intended for the warp of a fabric, specifically, a beam warper ...
OSHA 1910 General Industry > R Special Industries > 1910.262 Textiles > 1910.262(b) Definitions Applicable to This Section > 1910.262(b)(37) Warper
1910.262(i)(1) Special Industries, Swiveled Double-Bar Gates
Swiveled double-bar gates shall be installed on all warpers operating in excess of 450 yards per minute. These gates shall be so interlocked ...
OSHA 1910 General Industry > R Special Industries > 1910.262 Textiles > 1910.262(i) Warpers > 1910.262(i)(1) Swiveled Double-Bar Gates
1910.262(i)(2) Special Industries, Closed Position
Closed position shall mean that the top bar of the gate shall be at least 42 inches from the floor or working platform; and the lower bar shall ...
OSHA 1910 General Industry > R Special Industries > 1910.262 Textiles > 1910.262(i) Warpers > 1910.262(i)(2) Closed Position
1910.262(b) Special Industries, Definitions Applicable to This Section
is brought to the desired width. A warper is any ...
OSHA 1910 General Industry > R Special Industries > 1910.262 Textiles > 1910.262(b) Definitions Applicable to This Section
1910.262 Special Industries, Textiles
A warper is any machine for preparing and arranging the yarns intended for the warp of a fabric, specifically ...