3306.2 Walkways
JUMP TO FULL CODE CHAPTER
A walkway shall be provided for pedestrian
travel in front of every construction and demolition site
unless the applicable governing authority authorizes the sidewalk
to be fenced or closed. Walkways shall be of sufficient
width to accommodate the pedestrian traffic, but in no case
shall they be less than 4 feet (1219 mm) in width. Walkways
shall be provided with a durable walking surface. Walkways
shall be accessible in accordance with Chapter 11 and shall
be designed to support all imposed loads and in no case shall
the design live load be less than 150 pounds per square foot
(psf) (7.2 kN/m2).
Related Code Sections
1501.6.1 Construction Safeguards, Walkways
A walkway shall be provided for pedestrian travel in front of every construction and demolition site unless the applicable governing authority ...
2015 Michigan Rehabilitation Code > 15 Construction Safeguards > 1501 General > 1501.6 Protection of Pedestrians > 1501.6.1 Walkways
3306.2 Safeguards During Construction, Walkways
A walkway shall be provided for pedestrian
travel in front of every construction and demolition site
unless the applicable governing authority ...
2015 Michigan Building Code > 33 Safeguards During Construction > 3306 Protection of Pedestrians > 3306.2 Walkways
2409.1 Glass and Glazing, Glass Walkways
Glass installed as a part of a floor/ceiling assembly as a walking surface and constructed with
laminated glass shall comply with ASTM E2751 ...
2015 Michigan Building Code > 24 Glass and Glazing > 2409 Glass in Walkways, Elevator Hoistways and Elevator Cars > 2409.1 Glass Walkways
3104.10 Special Construction, Tunneled Walkway
Separation between the tunneled
walkway and the building to which it is connected shall
be not less than 2-hour fire-resistant construction ...
2015 Michigan Building Code > 31 Special Construction > 3104 Pedestrian Walkways and Tunnels > 3104.10 Tunneled Walkway
3202.3.4 Encroachments Into the Public Right-Of-Way, Pedestrian Walkways
The installation of a
pedestrian walkway over a public right-of-way shall be
subject to the approval of the applicable governing authority.
The ...
2015 Michigan Building Code > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.3 Encroachments 8 Feet or More Above Grade > 3202.3.4 Pedestrian Walkways