R404.4.3 Waffle-Grid Insulating Concrete Form Wall Systems
JUMP TO FULL CODE CHAPTER
Waffle-grid wall systems shall have a minimum nominal concrete thickness of 6 inches (152 mm) for the horizontal and vertical concrete members (cores) and shall be reinforced in accordance with Table R404.4(4). The minimum core dimension shall comply with Table R611.2 and Figure R611.4.
Related Code Sections
R611.4 Wall Construction, Waffle-Grid Insulating Concrete Form Wall Systems
Waffle-grid wall systems shall comply with Figure R611.4 and shall have reinforcement in accordance with Tables R611.3(1) and R611.4(1) and Section ...
2010 Residential Code of NY > 6 Wall Construction > R611 Insulating Concrete Form Wall Construction > R611.4 Waffle-Grid Insulating Concrete Form Wall Systems
R404.4.3 Foundations, Waffle-Grid Insulating Concrete Form Wall Systems
Waffle-grid wall systems shall have a minimum nominal concrete thickness of 6 inches (152 mm) for the horizontal and vertical concrete members (cores ...
2010 Residential Code of NY > 4 Foundations > R404 Foundation and Retaining Walls > R404.4 Insulating Concrete Form Foundation Walls > R404.4.3 Waffle-Grid Insulating Concrete Form Wall Systems
R608.5.4.6 Wall Construction, Webs of Waffle-Grid Walls
Reinforcement, including stirrups, shall not be placed in webs of waffle-grid walls, including lintels. Webs are permitted to have form ties ...
2020 Residential Code of New York State > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.4 Reinforcement Installation Details > R608.5.4.6 Webs of Waffle-Grid Walls
R608.5.4.6 Wall Construction, Webs of Waffle-Grid Walls
Reinforcement, including stirrups, shall not be placed in webs of waffle-grid walls, including lintels. Webs are permitted to have form ties ...
Residential Code 2015 of New York State > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.4 Reinforcement Installation Details > R608.5.4.6 Webs of Waffle-Grid Walls
R611.7.3.1 Wall Construction, General Requirements
in accordance with Figure R611.7(3) and Table R611.7(2) or R611.7(3). Lintels for waffle- grid ICF walls shall be constructed in accordance with Figure ...
2010 Residential Code of NY > 6 Wall Construction > R611 Insulating Concrete Form Wall Construction > R611.7 Wall Construction > R611.7.3 Lintels > R611.7.3.1 General Requirements