242.3 Wading Pools
Go To Full Code Chapter
At least one accessible means of entry shall be provided for wading pools. accessible means of entry shall comply with sloped entries complying with 1009.3.
Upcodes Diagrams
Related Code Sections
242.3 Scoping Requirements, Wading Pools
At least one accessible means of entry shall be provided for wading pools. accessible means of entry shall comply with sloped entries complying ...
1009 Recreation Facilities, Swimming Pools, Wading Pools, and Spas
shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level.
EXCEPTION: In wading pools, the sloped ...
1009.2.1 Recreation Facilities, Pool Lift Location
Pool lifts shall be located where the water level does not exceed 48 inches (1220 mm).
EXCEPTIONS:
Where the entire pool depth is greater ...
1009.2.2 Recreation Facilities, Seat Location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The ...
1009.2.3 Recreation Facilities, Clear Deck Space
clear deck space shall have a slope not steeper than 1:48. Figure 1009.2.3 Clear Deck Space at Pool Lifts ...