// CODE SNIPPET
A5.601.3.4 Voluntary Measures for Tier 2
JUMP TO FULL CODE CHAPTER
In addition to the provisions of Sections A5.601.3.1 and A5.601.3.3 above, compliance with the following voluntary measures from Appendix A5 and additional elective measures shown in Table A5.601.3.4 is required for Tier 2:
From Division A5.1,
- Comply with the designated parking requirements for fuel efficient vehicles for a minimum of 12 percent of parking capacity per Section A5.106.5.1 and Table A5.106.5.1.2.
- Comply with thermal emittance, solar reflectance or SRI values for cool roofs in Section A5.106.11.2 and Table A5.106.11.2.2.1
- Comply with three elective measures selected from this division.
From Division A5.3,
- Comply with the 20-percent reduction for indoor potable water use in Section A5.303.2.3.2.
- Comply with three elective measures selected from this division.
From Division A5.4,2
- Comply with recycled content of 15 percent of materials based on estimated total cost, or use two products from Table A5.405.4 for at least 75% by cost in Section A5.405.4.1.
- Comply with the 80-percent reduction in construction and demolition waste in Section A5.408.3.1.
- Comply with three elective measures selected from this division.
From Division A5.5,
Comply with resilient flooring systems for 100 percent of resilient flooring in Section A5.504.4.7.1.
Exception: Allowance may be permitted in Tier 2 for up to 5-percent specialty purpose flooring.
- Comply with thermal insulation meeting 2009 CHPS low-emitting materials list and no added formaldehyde in Section A5.504.4.8.1.
- Comply with three elective measures selected from this division.
- Comply with three additional elective measures selected from any division.
1 Cool roof is required for compliance with Tiers 1 and 2 and may be used to meet energy standards in Part 6, exceed energy standards and to mitigate heat island effect.
2 Life cycle assessment compliant with Section A5.409.4 in this code may be substituted for prescriptive measures from Division A5.4.
Related Code Sections
A5.601.3.4 Nonresidential Voluntary Measures, Voluntary Measures for Tier 2
and additional elective measures shown in Table A5.601.3.4 is required for Tier 2: From Division A5.1, Comply with the designated parking requirements ...
Los Angeles Green Building Code > A5 Nonresidential Voluntary Measures > A5.601 CALGreen Tier 1 and Tier 2 > A5.601.3 CALGreen Tier 2 > A5.601.3.4 Voluntary Measures for Tier 2
A5.601.3.4 Nonresidential Voluntary Measures, Voluntary Measures for Tier 2
and additional elective measures shown in Table A5.601.3.4 is required for Tier 2:
From Division A5.1,
Comply with the designated parking ...
Los Angeles Green Building Code > A5 Nonresidential Voluntary Measures > A5.601 CALGreen Tier 1 and Tier 2 > A5.601.3 CALGreen Tier 2 > A5.601.3.4 Voluntary Measures for Tier 2
A4.601.5.1 Residential Voluntary Measures, Mandatory Measures for Tier 2
The project shall meet or exceed all of the mandatory measures in Chapter 4, Divisions 4.1 through 4.5 and Chapter 7 as applicable ...
Los Angeles Green Building Code > A4 Residential Voluntary Measures > A4.601 General > A4.601.5 Tier 2 > A4.601.5.1 Mandatory Measures for Tier 2
A4.601.5.1 Residential Voluntary Measures, Mandatory Measures for Tier 2
The project shall meet or exceed all of the mandatory measures in Chapter 4, Divisions 4.1 through 4.5 and Chapter 7 as applicable ...
Los Angeles Green Building Code > A4 Residential Voluntary Measures > A4.601 General > A4.601.5 Tier 2 > A4.601.5.1 Mandatory Measures for Tier 2
A5.601.2 Nonresidential Voluntary Measures, CALGreen Tier 1
and A5.601.2.3 above, compliance with the following voluntary measures from Appendix A5 is required for Tier 1:
From Division A5.1,
Comply ...
Los Angeles Green Building Code > A5 Nonresidential Voluntary Measures > A5.601 CALGreen Tier 1 and Tier 2 > A5.601.2 CALGreen Tier 1