• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.268(s)(45) Voltage of a Circuit Not Effectively Grounded

OSHA 1910 General Industry > R Special Industries > 1910.268 Telecommunications > 1910.268(s) Definitions > 1910.268(s)(45) Voltage of a Circuit Not Effectively Grounded
JUMP TO FULL CODE CHAPTER
The voltage between any two conductors. If one circuit is directly connected to and supplied from another circuit of higher voltage (as in the case of an autotransformer), both are considered as of the higher voltage, unless the circuit of lower voltage is effectively grounded, in which case its voltage is not determined by the circuit of higher voltage. Direct connection implies electric connection as distinguished from connection merely through electromagnetic or electrostatic induction.

[40 FR 13441, Mar. 26, 1975, as amended at 43 FR 49751, Oct. 24, 1978; 47 FR 14706, Apr. 6, 1982; 52 FR 36387, Sept. 28, 1987; 54 FR 24334, June 7, 1989; 61 FR 9227, March 7, 1996; 63 FR 33450, June 18, 1998; 67 FR 67965, Nov. 7, 2002; 69 FR 31882, June 8, 2004; 70 FR 1141, Jan. 5, 2005; 81 83006, Nov. 18, 2016]

Related Code Sections


1910.268(s)(45) Special Industries, Voltage of a Circuit Not Effectively Grounded
of an autotransformer), both are considered as of the higher voltage, unless the circuit of lower voltage is effectively grounded, in which case its ...
OSHA 1910 General Industry > R Special Industries > 1910.268 Telecommunications > 1910.268(s) Definitions > 1910.268(s)(45) Voltage of a Circuit Not Effectively Grounded
1910.304(b)(2) Electrical, Receptacles and Cord Connectors
in paragraph (b)(2)(iv) of this section. Grounding-type receptacles shall be installed only on circuits of the voltage class and current for which they are rated ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection > 1910.304(b) Branch Circuits > 1910.304(b)(2) Receptacles and Cord Connectors
1910.255(b)(1) Welding, Cutting, and Brazing, Voltage
All external weld initiating control circuits shall operate on low voltage, not over 120 volts, for the safety of the operators ...
OSHA 1910 General Industry > Q Welding, Cutting, and Brazing > 1910.255 Resistance Welding > 1910.255(b) Spot and Seam Welding Machines (Nonportable) > 1910.255(b)(1) Voltage
1910.304(f)(1)(ix) Electrical,
V or 480Y/277 V, may only be installed in a circuit where the nominal voltage of any conductor to ground does not exceed the lower of the two values ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection > 1910.304(f) Overcurrent Protection > 1910.304(f)(1) 600 Volts, Nominal, or Less > 1910.304(f)(1)(ix)
1910.306(g)(1) Electrical, Guarding and Grounding
The converting apparatus (including the dc line) and high-frequency electric circuits (excluding the output circuits and remote-control circuits ...
OSHA 1910 General Industry > S Electrical > 1910.306 Specific Purpose Equipment and Installations > 1910.306(g) Induction and Dielectric Heating Equipment > 1910.306(g)(1) Guarding and Grounding
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE