1910.268(s)(45) Voltage of a Circuit Not Effectively Grounded
JUMP TO FULL CODE CHAPTER
The voltage between any two conductors. If one circuit is directly connected to and supplied from another circuit of higher voltage (as in the case of an autotransformer), both are considered as of the higher voltage, unless the circuit of lower voltage is effectively grounded, in which case its voltage is not determined by the circuit of higher voltage. Direct connection implies electric connection as distinguished from connection merely through electromagnetic or electrostatic induction.
[40 FR 13441, Mar. 26, 1975, as amended at 43 FR 49751, Oct. 24, 1978; 47 FR 14706, Apr. 6, 1982; 52 FR 36387, Sept. 28, 1987; 54 FR 24334, June 7, 1989; 61 FR 9227, March 7, 1996; 63 FR 33450, June 18, 1998; 67 FR 67965, Nov. 7, 2002; 69 FR 31882, June 8, 2004; 70 FR 1141, Jan. 5, 2005; 81 83006, Nov. 18, 2016]
[40 FR 13441, Mar. 26, 1975, as amended at 43 FR 49751, Oct. 24, 1978; 47 FR 14706, Apr. 6, 1982; 52 FR 36387, Sept. 28, 1987; 54 FR 24334, June 7, 1989; 61 FR 9227, March 7, 1996; 63 FR 33450, June 18, 1998; 67 FR 67965, Nov. 7, 2002; 69 FR 31882, June 8, 2004; 70 FR 1141, Jan. 5, 2005; 81 83006, Nov. 18, 2016]
Related Code Sections
1910.268(s)(45) Special Industries, Voltage of a Circuit Not Effectively Grounded
of an autotransformer), both are considered as of the higher voltage, unless the circuit of lower voltage is effectively grounded, in which case its ...
OSHA 1910 General Industry > R Special Industries > 1910.268 Telecommunications > 1910.268(s) Definitions > 1910.268(s)(45) Voltage of a Circuit Not Effectively Grounded
1910.304(b)(2) Electrical, Receptacles and Cord Connectors
in paragraph (b)(2)(iv) of this section. Grounding-type receptacles shall be installed only on circuits of the voltage class and current for which they are rated ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection > 1910.304(b) Branch Circuits > 1910.304(b)(2) Receptacles and Cord Connectors
1910.255(b)(1) Welding, Cutting, and Brazing, Voltage
All external weld initiating control circuits shall operate on low voltage, not over 120 volts, for the safety of the operators ...
OSHA 1910 General Industry > Q Welding, Cutting, and Brazing > 1910.255 Resistance Welding > 1910.255(b) Spot and Seam Welding Machines (Nonportable) > 1910.255(b)(1) Voltage
1910.304(f)(1)(ix) Electrical,
V or 480Y/277 V, may only be installed in a circuit where the nominal voltage of any conductor to ground does not exceed the lower of the two values ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection > 1910.304(f) Overcurrent Protection > 1910.304(f)(1) 600 Volts, Nominal, or Less > 1910.304(f)(1)(ix)
1910.306(g)(1) Electrical, Guarding and Grounding
The converting apparatus (including the dc line) and high-frequency electric circuits (excluding the output circuits and remote-control circuits ...
OSHA 1910 General Industry > S Electrical > 1910.306 Specific Purpose Equipment and Installations > 1910.306(g) Induction and Dielectric Heating Equipment > 1910.306(g)(1) Guarding and Grounding