// CODE SNIPPET
128-43 Visual Corridors in the North Waterfront Subdistrict
JUMP TO FULL CODE CHAPTER
The designated locations for visual corridors, as defined in Article VI, Chapter 2, are shown on Map 5 in the Appendix to this Chapter. Such visual corridors shall be provided in accordance with the standards of Sections 62-512 (Dimensions of visual corridors) and 62-513 (Permitted obstructions in visual corridors), except that:
(a) lighting fixtures in visual corridors shall be considered permitted obstructions; and
(b) within the visual corridor provided through Parcel 2 to the Pierhead line within the flexible location zone indicated on Map 5, a portion of a building shall be a permitted obstruction, provided that such obstruction is located no more than 14 feet above the reference plane of the visual corridor, and that such obstruction occupies no more than 185,000 cubic feet in total above the reference plane of the visual corridor.
Related Code Sections
407.6 Special Detailed Requirements Based on Use and Occupancy, Automatic Fire Detection
provide a visual display on the corridor side of each patient sleeping unit and an audible and visual alarm at the nursing station attending each unit ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 407 Group I-2 > 407.6 Automatic Fire Detection
407.7 Special Detailed Requirements Based on Use and Occupancy, Automatic Fire Detection
are provided with smoke detectors that comply with UL 268. Such detectors shall provide a visual display on the corridor side of each patient sleeping unit ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 407 Group I-2 > 407.7 Automatic Fire Detection
407.8 Special Detailed Requirements Based on Use and Occupancy, Automatic Fire Detection
sleeping rooms are provided with smoke detectors that comply with UL 268. Such detectors shall provide a visual display on the corridor side of each ...
NYC Building Code 2022 > 4 Special Detailed Requirements Based on Use and Occupancy > 407 Group I-2 > 407.8 Automatic Fire Detection
§28-103.1.2 Administration, Enforcement of New York City Construction Codes on Property Within the Jurisdiction of the Department of Small Business Services
York city charter including, but not limited to, structures on waterfront property used in conjunction with and in furtherance of waterfront commerce ...
NYC General Admin. Provisions 2014 > 1 Administration > 103 Duties and Powers of Commissioner of Buildings > *§28-103.1 Jurisdiction > §28-103.1.2 Enforcement of New York City Construction Codes on Property Within the Jurisdiction of the Department of Small Business Services
§28-103.1.2 Administration, Enforcement of New York City Construction Codes on Property Within the Jurisdiction of the Department of Small Business Services
York city charter including, but not limited to, structures on waterfront property used in conjunction with and in furtherance of waterfront commerce ...
NYC General Admin. Provisions 2022 > 1 Administration > 103 Duties and Powers of Commissioner of Buildings > *§28-103.1 Jurisdiction > §28-103.1.2 Enforcement of New York City Construction Codes on Property Within the Jurisdiction of the Department of Small Business Services