// CODE SNIPPET
1228.14.7 Visitor/Consultation Room(s)
JUMP TO FULL CODE CHAPTER
Visitor/consultation
rooms shall be provided at a room-to-bed ratio of one
consultation room for each 12 psychiatric beds, or major
fraction thereof with a minimum of one, in each psychiatric
nursing unit. Additionally, the following requirements
shall be met:
- Visitor/consultation room(s) shall have a minimum clear floor area of 100 square feet (9.29 m2).
- The room(s) shall be designed for acoustical and visual privacy. Refer to Table 1224.4.19, Sound Transmission Limitations in Hospitals.
Related Code Sections
1228.14.7 Interior Environment, Visitor/Consultation Room(s)
with a minimum of one, in each psychiatric
nursing unit. Additionally, the following requirements
shall be met:
Visitor/consultation room(s) shall ...
Los Angeles Building Code > 12 Interior Environment > 1228 Acute Psychiatric Hospitals > 1228.14 Psychiatric Nursing Service Space > 1228.14.7 Visitor/Consultation Room(s)
1224.29.1.15 Interior Environment, Support
The following shall be provided and shall be located immediately accessible to the unit: Visitors' waiting room. Office space. Staff ...
Los Angeles Building Code > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.29 Intensive Care Units > 1224.29.1 General > 1224.29.1.15 Support
1226.6.2.5 Interior Environment, Consultation Room
Dental facilities must provide a consultation room for private conferences with patients ...
Los Angeles Building Code > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.6 Primary Care Clinics > 1226.6.2 Support Areas for Examination Rooms > 1226.6.2.5 Consultation Room
1224.14.5 Interior Environment, Seclusion Room(s)
may be part of the psychiatric unit described in Section 1224.31. If the single bedroom(s) is part of the acute-care nursing unit, the provisions ...
Los Angeles Building Code > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.14 Nursing Service Space > 1224.14.5 Seclusion Room(s)
1224.39.5.5.2 Interior Environment, Examination/Treatment Room(s)
Room(s) for individual consultation and treatment shall be provided and meet the requirements of Section 1224.4.4.1 ...
Los Angeles Building Code > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.39 Outpatient Service Space > 1224.39.5 Hyperbaric Therapy Service Space > 1224.39.5.5 Support Areas for the Hyperbaric Suite > 1224.39.5.5.2 Examination/Treatment Room(s)