// CODE SNIPPET
3008.7.3.1 Vision Panel
Related Code Sections
3008.7.3.1 Elevators and Conveying Systems, Vision Panel
A vision panel shall be installed in each door assembly protecting the lobby doorway. The vision panel shall consist of glazing and shall be located ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.7 Occupant Evacuation Elevator Lobby > 3008.7.3 Lobby Doorways > 3008.7.3.1 Vision Panel
2409.2 Glass and Glazing, Glass Visions Panels
Glass in vision panels in elevator hoistway doors shall be permitted to be any transparent glazing material not less than 1 / 4 inches (6.4 mm ...
NYC Building Code 2014 > 24 Glass and Glazing > 2409 Glass in Elevator Hoistways and Elevator Cars > 2409.2 Glass Visions Panels
Article 14 Elevators [PDF] (page 24)
equipped with swing doors, shall each be provided with a vision panel. b. Such vision panel in an elevator hoistway door shall be of clear wired plate ...
709.5 Fire-Resistance-Rated Construction, Openings
are installed across corridors, a pair of opposite-swinging doors without a center mullion shall be installed having vision panels with approved fire-resistance ...
715.4.7.1 Fire and Smoke Protection Features, Size Limitations
shall be permitted to have a vision panel of not more than 100 square inches (0.065 m 2 ) without a dimension exceeding 10 inches (254 mm). Fire ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 715 Opening Protectives > 715.4 Fire Door and Shutter Assemblies > 715.4.7 Glazing Material > 715.4.7.1 Size Limitations