407.2.2.2 Visible Signals
Go To Full Code Chapter
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground. The visible signal elements shall be 21/2 inches (64 mm) minimum measured along the vertical centerline of the element. Signals shall be visible from the floor area adjacent to the hall call button.
EXCEPTIONS:
- Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance.
- Existing elevators shall not be required to comply with 407.2.2.2.
![]() |