• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

11B-411.2.2.1 Visible Identification

California Building Code 2016 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-411 Destination-Oriented Elevators > 11B-411.2 Elevator Landing Requirements > 11B-411.2.2 Elevator Car Identification at Elevator Landings > 11B-411.2.2.1 Visible Identification
JUMP TO FULL CODE CHAPTER
Above or adjacent to each elevator car entrance there shall be a visible identification fixture with a car designation character. The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture. The characters on the fixture shall be upper case with a height of 4 inches (102 mm) minimum complying with Sections 11B-703.5.1, 11B-703.5.3, 11B-703.5.4, 11B-703.5.7, and 11B-703.5.8.
Exception: Existing buildings shall be permitted to have a visible identification fixture with a car designation character adjacent to each elevator car entrance centered at 72 inches (1829 mm) above the finish floor or ground. The character on the fixture shall be upper case with a height of 21/2 inches (64 mm) minimum complying with Sections 11B-703.5.1, 11B-703.5.3, 11B-703.5.4, 11B-703.5.7, and 11B-703.5.8.

Related Code Sections


11B-411.2.2.1 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Visible Identification
Above or adjacent to each elevator car entrance there shall be a visible identification fixture with a car designation character. The identification ...
California Building Code 2016 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-411 Destination-Oriented Elevators > 11B-411.2 Elevator Landing Requirements > 11B-411.2.2 Elevator Car Identification at Elevator Landings > 11B-411.2.2.1 Visible Identification
11B-411.2.2.1 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Visible Identification
Above or adjacent to each elevator car entrance there shall be a visible identification fixture with a car designation character. The identification ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-411 Destination-Oriented Elevators > 11B-411.2 Elevator Landing Requirements > 11B-411.2.2 Elevator Car Identification at Elevator Landings > 11B-411.2.2.1 Visible Identification
5503.4.1 Cryogenic Fluids, Identification Signs
Visible hazard identification signs in accordance with NFPA 704 shall be provided at entrances to buildings or areas in which cryogenic fluids ...
California Fire Code 2016 > 55 Cryogenic Fluids > 5503 General Requirements > 5503.4 Marking > 5503.4.1 Identification Signs
5503.4.1 Cryogenic Fluids, Identification Signs
Visible hazard identification signs in accordance with NFPA 704 shall be provided at entrances to buildings or areas in which cryogenic fluids ...
California Fire Code 2019 > 55 Cryogenic Fluids > 5503 General Requirements > 5503.4 Marking > 5503.4.1 Identification Signs
11B-411.2.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Elevator Car Identification at Elevator Landings
Above or adjacent to each elevator car entrance there shall be a visible identification fixture with a car designation character. The ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-411 Destination-Oriented Elevators > 11B-411.2 Elevator Landing Requirements > 11B-411.2.2 Elevator Car Identification at Elevator Landings
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING