• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3307.7.3 Viewing Panels

NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians > 3307.7 Fences > 3307.7.3 Viewing Panels
JUMP TO FULL CODE CHAPTER
Viewing panels shall be provided in solid fences erected on or after July 1, 2013, at a rate one for every 25 linear feet (7.6 m) per frontage, with a minimum of one per frontage. Viewing panels shall be 12 inches by 12 inches (305 by 305 mm) in size and shall be blocked with plexiglass or an equivalent nonfrangible material. The top of the viewing panel shall be located no more than 6 feet (1829 mm) above the level of the ground, and the bottom of the viewing panel shall be located no less than 3 feet (914 mm) above the level of the ground.

Related Code Sections


3307.7.1 Safeguards During Construction or Demolition, Viewing Panels
Viewing panels shall be provided in solid fences erected on or after July 1, 2013, at a rate of one for every 25 linear feet (7.6 m) per frontage ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians > 3307.7 Fences > 3307.7.1 Viewing Panels
3307.7.3 Safeguards During Construction or Demolition, Viewing Panels
Viewing panels shall be provided in solid fences erected on or after July 1, 2013, at a rate one for every 25 linear feet (7.6 m) per frontage ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians > 3307.7 Fences > 3307.7.3 Viewing Panels
2406.1.2 Glass and Glazing, Wired Glass
In other than Group E, wired glass installed in fire doors, fire windows and view panels in fire-resistant walls shall comply with ANSI Z97.1 ...
NYC Building Code 2008 > 24 Glass and Glazing > 2406 Safety Glazing > 2406.1 Human Impact Loads > 2406.1.2 Wired Glass
§28-105.9 Administration, Expiration
with view panels including the posting of work permits and removal of any unlawful flyers or posters; installation of proper shoring of excavated ...
NYC General Admin. Provisions 2008 > 1 Administration > 105 Permits > §28-105.9 Expiration
Section 3307 Safeguards During Construction or Demolition, Protection of Pedestrians
Viewing panels shall be provided in solid fences erected on or after July 1, 2013 ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE